Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1584,16 +1584,13 @@ 1584 1584 [[image:image-20220829152102-5.png]] 1585 1585 1586 1586 1587 -(% class="wikigeneratedid" %) 1588 1588 == **DVP Ethernet Protocol** == 1589 1589 1590 - 1591 1591 (% class="wikigeneratedid" %) 1592 1592 Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller 1593 1593 1594 1594 **1)HMI Settings** 1595 1595 1596 - 1597 1597 |**Items**|**Settings**|**Note** 1598 1598 |Protocol|DELTA DVP Modbus TCP| 1599 1599 |Connection|Ethernet| ... ... @@ -1630,6 +1630,62 @@ 1630 1630 1631 1631 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1632 1632 1630 +== **AS serial protocol** == 1631 + 1632 +**1)HMI Settings** 1633 + 1634 +|**Item**|**Settings**|**Note** 1635 +|Protocol|DELTA AS300 MODBUS RTU| 1636 +|Connection|RS485| 1637 +|Baud rate|9600| 1638 +|Data bit|8| 1639 +|Parity|NONE| 1640 +|Stop bit|1| 1641 +|PLC station No.|1| 1642 + 1643 +**2)Address List** 1644 + 1645 + 1646 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1647 +|Bit|X|X|X d|0~~63| 1648 +|Bit|Y|Y|Y d|0~~63| 1649 +|Bit|D|D|D d|0~~29999| 1650 +|Bit|M|M|M d|0~~8191| 1651 +|Bit|SM|SM|SM d|0~~4095| 1652 +|Bit|S|S|S h|0~~2047| 1653 +|Bit|T|T|T d|0~~511| 1654 +|Bit|C|C|C d|0~~511| 1655 +|Bit|HC|HC|HC d|0~~255| 1656 +|Word|X|X|X h|0~~63| 1657 +|Word|Y|Y|Y d|0~~63| 1658 +|Word|SR|SR|SR d|0~~2047| 1659 +|Word|D|D|D d|0~~29999| 1660 +|Word|T|T|T d|0~~511| 1661 +|Word|C|C|C h|0~~511| 1662 +|Word|E|E|E d|0~~9| 1663 + 1664 +**3)Configure the communication protocol** 1665 + 1666 +[[image:image-20220830094600-1.png]] 1667 + 1668 +[[image:image-20220830094657-2.png]] 1669 + 1670 +**4)Cable Wiring** 1671 + 1672 +[[image:image-20220830095131-1.png]] 1673 + 1674 +== **AS Ethernet Protocol** == 1675 + 1676 +**1)HMI Settings** 1677 + 1678 +**2)Address List** 1679 + 1680 +**3)Configure the communication protocol** 1681 + 1682 +**4)Cable Wiring** 1683 + 1684 +[[image:image-20220830094929-1.png]] 1685 + 1633 1633 = **MODBUS** = 1634 1634 1635 1635 == **MODBUS RTU Master** ==
- image-20220830094600-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content
- image-20220830094657-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.4 KB - Content
- image-20220830094929-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.4 KB - Content
- image-20220830095131-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.7 KB - Content