... ... @@ -1632,31 +1632,34 @@
1632 1632  **1)HMI Settings**
1633 1633  
1634 1634  |**Item**|**Settings**|**Note**
1635 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
1636 -|Connection|RS422/RS485|
1635 +|Protocol|DELTA AS300 MODBUS RTU|
1636 +|Connection|RS485|
1637 1637  |Baud rate|9600|
1638 -|Data bit|7|
1639 -|Parity|EVEN|
1638 +|Data bit|8|
1639 +|Parity|NONE|
1640 1640  |Stop bit|1|
1641 1641  |PLC station No.|1|
1642 1642  
1643 1643  **2)Address List**
1644 1644  
1645 +
1645 1645  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1646 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
1647 -|Y|Y|Y o|0~~303237|
1648 -|M|M|M d|0~~99999|
1649 -|T|T|T d|0~~99999|
1650 -|C|C|C d|0~~99999|
1651 -|S|S|S d|0~~99999|
1652 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
1653 -|Y|Y|Y o|0~~303237|
1654 -|M|M|M d|0~~99999|
1655 -|T|T|T d|0~~99999|
1656 -|C|C|C d|0~~199|
1657 -|D|D|D d|0~~7999|
1658 -|S|S|S d|0~~99999|
1659 -|SD|SD|SD d|8000~~9999|
1647 +|Bit|X|X|X d|0~~63|
1648 +|Bit|Y|Y|Y d|0~~63|
1649 +|Bit|D|D|D d|0~~29999|
1650 +|Bit|M|M|M d|0~~8191|
1651 +|Bit|SM|SM|SM d|0~~4095|
1652 +|Bit|S|S|S h|0~~2047|
1653 +|Bit|T|T|T d|0~~511|
1654 +|Bit|C|C|C d|0~~511|
1655 +|Bit|HC|HC|HC d|0~~255|
1656 +|Word|X|X|X h|0~~63|
1657 +|Word|Y|Y|Y d|0~~63|
1658 +|Word|SR|SR|SR d|0~~2047|
1659 +|Word|D|D|D d|0~~29999|
1660 +|Word|T|T|T d|0~~511|
1661 +|Word|C|C|C h|0~~511|
1662 +|Word|E|E|E d|0~~9|
1660 1660  
1661 1661  **3)Configure the communication protocol**
1662 1662  
... ... @@ -1666,7 +1666,7 @@
1666 1666  
1667 1667  **4)Cable Wiring**
1668 1668  
1669 -
1672 +[[image:image-20220830095131-1.png]]
1670 1670  
1671 1671  == **AS Ethernet Protocol** ==
1672 1672  
... ... @@ -1678,6 +1678,8 @@
1678 1678  
1679 1679  **4)Cable Wiring**
1680 1680  
1684 +[[image:image-20220830094929-1.png]]
1685 +
1681 1681  = **MODBUS** =
1682 1682  
1683 1683  == **MODBUS RTU Master** ==
image-20220830094929-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.4 KB
Content
image-20220830095131-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +25.7 KB
Content