Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 105.1
edited by Ben
on 2022/08/30 09:49
Change comment: There is no comment for this version
To version 102.1
edited by Ben
on 2022/08/29 16:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1584,13 +1584,16 @@
1584 1584  [[image:image-20220829152102-5.png]]
1585 1585  
1586 1586  
1587 +(% class="wikigeneratedid" %)
1587 1587  == **DVP Ethernet Protocol** ==
1588 1588  
1590 +
1589 1589  (% class="wikigeneratedid" %)
1590 1590  Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller
1591 1591  
1592 1592  **1)HMI Settings**
1593 1593  
1596 +
1594 1594  |**Items**|**Settings**|**Note**
1595 1595  |Protocol|DELTA DVP Modbus TCP|
1596 1596  |Connection|Ethernet|
... ... @@ -1627,59 +1627,6 @@
1627 1627  
1628 1628  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1629 1629  
1630 -== **AS serial protocol** ==
1631 -
1632 -**1)HMI Settings**
1633 -
1634 -|**Item**|**Settings**|**Note**
1635 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
1636 -|Connection|RS422/RS485|
1637 -|Baud rate|9600|
1638 -|Data bit|7|
1639 -|Parity|EVEN|
1640 -|Stop bit|1|
1641 -|PLC station No.|1|
1642 -
1643 -**2)Address List**
1644 -
1645 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1646 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
1647 -|Y|Y|Y o|0~~303237|
1648 -|M|M|M d|0~~99999|
1649 -|T|T|T d|0~~99999|
1650 -|C|C|C d|0~~99999|
1651 -|S|S|S d|0~~99999|
1652 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
1653 -|Y|Y|Y o|0~~303237|
1654 -|M|M|M d|0~~99999|
1655 -|T|T|T d|0~~99999|
1656 -|C|C|C d|0~~199|
1657 -|D|D|D d|0~~7999|
1658 -|S|S|S d|0~~99999|
1659 -|SD|SD|SD d|8000~~9999|
1660 -
1661 -**3)Configure the communication protocol**
1662 -
1663 -[[image:image-20220830094600-1.png]]
1664 -
1665 -[[image:image-20220830094657-2.png]]
1666 -
1667 -**4)Cable Wiring**
1668 -
1669 -
1670 -
1671 -== **AS Ethernet Protocol** ==
1672 -
1673 -**1)HMI Settings**
1674 -
1675 -**2)Address List**
1676 -
1677 -**3)Configure the communication protocol**
1678 -
1679 -**4)Cable Wiring**
1680 -
1681 -[[image:image-20220830094929-1.png]]
1682 -
1683 1683  = **MODBUS** =
1684 1684  
1685 1685  == **MODBUS RTU Master** ==
image-20220830094600-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -40.4 KB
Content
image-20220830094657-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -53.4 KB
Content
image-20220830094929-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -90.4 KB
Content