Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1632,31 +1632,34 @@ 1632 1632 **1)HMI Settings** 1633 1633 1634 1634 |**Item**|**Settings**|**Note** 1635 -|Protocol| WECONLX2V/LX2E/ LX3V/LX3VP/LX3VE/LX3VM|1636 -|Connection|RS4 22/RS485|1635 +|Protocol|DELTA AS300 MODBUS RTU| 1636 +|Connection|RS485| 1637 1637 |Baud rate|9600| 1638 -|Data bit| 7|1639 -|Parity| EVEN|1638 +|Data bit|8| 1639 +|Parity|NONE| 1640 1640 |Stop bit|1| 1641 1641 |PLC station No.|1| 1642 1642 1643 1643 **2)Address List** 1644 1644 1645 + 1645 1645 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1646 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 1647 -|Y|Y|Y o|0~~303237| 1648 -|M|M|M d|0~~99999| 1649 -|T|T|T d|0~~99999| 1650 -|C|C|C d|0~~99999| 1651 -|S|S|S d|0~~99999| 1652 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 1653 -|Y|Y|Y o|0~~303237| 1654 -|M|M|M d|0~~99999| 1655 -|T|T|T d|0~~99999| 1656 -|C|C|C d|0~~199| 1657 -|D|D|D d|0~~7999| 1658 -|S|S|S d|0~~99999| 1659 -|SD|SD|SD d|8000~~9999| 1647 +|Bit|X|X|X d|0~~63| 1648 +|Bit|Y|Y|Y d|0~~63| 1649 +|Bit|D|D|D d|0~~29999| 1650 +|Bit|M|M|M d|0~~8191| 1651 +|Bit|SM|SM|SM d|0~~4095| 1652 +|Bit|S|S|S h|0~~2047| 1653 +|Bit|T|T|T d|0~~511| 1654 +|Bit|C|C|C d|0~~511| 1655 +|Bit|HC|HC|HC d|0~~255| 1656 +|Word|X|X|X h|0~~63| 1657 +|Word|Y|Y|Y d|0~~63| 1658 +|Word|SR|SR|SR d|0~~2047| 1659 +|Word|D|D|D d|0~~29999| 1660 +|Word|T|T|T d|0~~511| 1661 +|Word|C|C|C h|0~~511| 1662 +|Word|E|E|E d|0~~9| 1660 1660 1661 1661 **3)Configure the communication protocol** 1662 1662