... ... @@ -2478,9 +2478,9 @@
2478 2478  **✎Note:** COM3 only available in PI8000/PI9000 series.
2479 2479  
2480 2480  
2481 -== **2 Communication with Wecon LX5V** ==
2481 +== **1 HMI and Wecon LX5V serial communication** ==
2482 2482  
2483 -This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2483 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2484 2484  
2485 2485  
2486 2486  **Software configuration of PLC**
... ... @@ -2493,7 +2493,7 @@
2493 2493  
2494 2494  Click New Project and select the PLC model.
2495 2495  
2496 -[[image:image-20220810165247-2.png]]
2496 +[[image:image-20220810172412-1.png]]
2497 2497  
2498 2498  
2499 2499  **3)Set Serial port parameters**
... ... @@ -2511,6 +2511,11 @@
2511 2511  [[image:image-20220810165759-3.png]]
2512 2512  
2513 2513  
2514 +**4)Registers list**
2515 +
2516 +[[image:image-20220811102219-3.png]]
2517 +
2518 +
2514 2514  **HMI software configuration**
2515 2515  
2516 2516  **1)HMI programming software**
... ... @@ -2525,28 +2525,107 @@
2525 2525  
2526 2526  **3)Set communication port parameters**
2527 2527  
2528 -In the device list on the leftfind the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
2533 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2529 2529  
2530 -[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162805-9.png?rev=1.1||alt="image-20220714162805-9.png"]]
2535 +Baud rate115200
2531 2531  
2532 -The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
2537 +Data bit8
2533 2533  
2534 -[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162814-10.png?rev=1.1||alt="image-20220714162814-10.png"]]
2539 +Stop bit1
2535 2535  
2536 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162827-11.png?rev=1.1||alt="image-20220714162827-11.png"]]
2541 +Parity:No verification
2537 2537  
2538 -**5)Engineering production**
2539 2539  
2540 -According to your own needs, use the V-NET client software to edit the required data monitoring points.
2544 +[[image:image-20220811104012-1.png]]
2541 2541  
2542 -[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162841-12.png?rev=1.1||alt="image-20220714162841-12.png"]]
2543 2543  
2544 2544  **hardware connection**
2545 2545  
2546 2546  **1)Hardware wiring diagram**
2547 2547  
2548 -This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
2551 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2549 2549  
2550 -[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162856-13.png?rev=1.1||alt="image-20220714162856-13.png"]]
2553 +[[image:image-20220811103005-4.png]]
2551 2551  
2552 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
2555 +
2556 +[[image:image-20220811103227-7.png]]
2557 +
2558 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2559 +
2560 +
2561 +== **2 HMI and Wecon LX5V-N Ethernet communication** ==
2562 +
2563 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2564 +
2565 +
2566 +**Software configuration of PLC**
2567 +
2568 +**1)PLC programming software**
2569 +
2570 +[[image:image-20220810164710-1.png]]
2571 +
2572 +**2)New PLC project**
2573 +
2574 +Click New Project and select the PLC model.
2575 +
2576 +[[image:image-20220811115454-1.png]]
2577 +
2578 +
2579 +**3)Set Ethernet port parameters**
2580 +
2581 +Follow the steps below to configure Serial port parameters
2582 +
2583 +PLC IP address:192.168.39.200
2584 +
2585 +default gateway:192.168.39.1
2586 +
2587 +subnet mask:255.255.255.0
2588 +
2589 +[[image:image-20220811140530-2.png]]
2590 +
2591 +
2592 +**4)Registers list**
2593 +
2594 +[[image:image-20220811102219-3.png]]
2595 +
2596 +
2597 +**HMI software configuration**
2598 +
2599 +**1)HMI programming software**
2600 +
2601 + [[image:image-20220810171237-4.png]]
2602 +
2603 +**2)New HMI project**
2604 +
2605 +Click New Project and select the HMI model.
2606 +
2607 +[[image:image-20220810172010-5.png]]
2608 +
2609 +**3)Set communication port parameters**
2610 +
2611 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2612 +
2613 +Baud rate:115200
2614 +
2615 +Data bit:8
2616 +
2617 +Stop bit:1
2618 +
2619 +Parity:No verification
2620 +
2621 +
2622 +[[image:image-20220811104012-1.png]]
2623 +
2624 +
2625 +**hardware connection**
2626 +
2627 +**1)Hardware wiring diagram**
2628 +
2629 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2630 +
2631 +[[image:image-20220811103005-4.png]]
2632 +
2633 +
2634 +[[image:image-20220811103227-7.png]]
2635 +
2636 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
image-20220810172412-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.3 KB
Content
image-20220811102219-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.8 KB
Content
image-20220811103005-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +72.7 KB
Content
image-20220811103131-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +256.1 KB
Content
image-20220811103200-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +17.6 KB
Content
image-20220811103227-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +16.0 KB
Content
image-20220811104012-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +113.6 KB
Content
image-20220811115454-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@