Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,7 +511,7 @@ 511 511 (% style="text-align:center" %) 512 512 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 513 514 -== **FreeTag Ethernet /IP(CompactLogix)** ==514 +== **CompactLogix FreeTag Ethernet protocol** == 515 515 516 516 Allen-Brandly CompactLogix 517 517 ... ... @@ -568,7 +568,7 @@ 568 568 (% style="text-align:center" %) 569 569 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 570 570 571 -== ** AB PLCaddressedit** ==571 +== **MicroLogix 1200** ** protocol** == 572 572 573 573 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. 574 574 ... ... @@ -1675,14 +1675,51 @@ 1675 1675 1676 1676 **1)HMI Settings** 1677 1677 1678 + 1679 +|=**Items**|=**Settings**|=**Note** 1680 +|Protocol|DELTA AS300 MODBUS TCP| 1681 +|Connection|Ethernet| 1682 +|Port No.|502| 1683 +|Device No.|1| 1684 +|HMI No.|0| 1685 + 1678 1678 **2)Address List** 1679 1679 1688 + 1689 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1690 +|Bit|X|X|X d|0~~63| 1691 +|Bit|Y|Y|Y d|0~~63| 1692 +|Bit|D|D|D d|0~~29999| 1693 +|Bit|M|M|M d|0~~8191| 1694 +|Bit|SM|SM|SM d|0~~4095| 1695 +|Bit|S|S|S h|0~~2047| 1696 +|Bit|T|T|T d|0~~511| 1697 +|Bit|C|C|C d|0~~511| 1698 +|Bit|HC|HC|HC d|0~~255| 1699 +|Word|X|X|X h|0~~63| 1700 +|Word|Y|Y|Y d|0~~63| 1701 +|Word|SR|SR|SR d|0~~2047| 1702 +|Word|D|D|D d|0~~29999| 1703 +|Word|T|T|T d|0~~511| 1704 +|Word|C|C|C h|0~~511| 1705 +|Word|E|E|E d|0~~9| 1706 + 1680 1680 **3)Configure the communication protocol** 1681 1681 1709 +[[image:image-20220830140537-1.png]] 1710 + 1711 +[[image:image-20220830140629-2.png]] 1712 + 1682 1682 **4)Cable Wiring** 1683 1683 1715 +Physical map 1716 + 1684 1684 [[image:image-20220830094929-1.png]] 1685 1685 1719 +Pin Definition Diagram 1720 + 1721 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1722 + 1686 1686 = **MODBUS** = 1687 1687 1688 1688 == **MODBUS RTU Master** ==
- image-20220830140537-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.2 KB - Content
- image-20220830140629-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.4 KB - Content