Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 111.1
edited by Ben
on 2022/08/30 13:55
Change comment: There is no comment for this version
To version 115.1
edited by Ben
on 2022/08/30 14:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -568,7 +568,7 @@
568 568  (% style="text-align:center" %)
569 569  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
570 570  
571 -== **AB PLC address edit** ==
571 +== **MicroLogix 1200** ** protocol** ==
572 572  
573 573  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
574 574  
... ... @@ -1675,14 +1675,51 @@
1675 1675  
1676 1676  **1)HMI Settings**
1677 1677  
1678 +
1679 +|=**Items**|=**Settings**|=**Note**
1680 +|Protocol|DELTA AS300 MODBUS TCP|
1681 +|Connection|Ethernet|
1682 +|Port No.|502|
1683 +|Device No.|1|
1684 +|HMI No.|0|
1685 +
1678 1678  **2)Address List**
1679 1679  
1688 +
1689 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1690 +|Bit|X|X|X d|0~~63|
1691 +|Bit|Y|Y|Y d|0~~63|
1692 +|Bit|D|D|D d|0~~29999|
1693 +|Bit|M|M|M d|0~~8191|
1694 +|Bit|SM|SM|SM d|0~~4095|
1695 +|Bit|S|S|S h|0~~2047|
1696 +|Bit|T|T|T d|0~~511|
1697 +|Bit|C|C|C d|0~~511|
1698 +|Bit|HC|HC|HC d|0~~255|
1699 +|Word|X|X|X h|0~~63|
1700 +|Word|Y|Y|Y d|0~~63|
1701 +|Word|SR|SR|SR d|0~~2047|
1702 +|Word|D|D|D d|0~~29999|
1703 +|Word|T|T|T d|0~~511|
1704 +|Word|C|C|C h|0~~511|
1705 +|Word|E|E|E d|0~~9|
1706 +
1680 1680  **3)Configure the communication protocol**
1681 1681  
1709 +[[image:image-20220830140537-1.png]]
1710 +
1711 +[[image:image-20220830140629-2.png]]
1712 +
1682 1682  **4)Cable Wiring**
1683 1683  
1715 +Physical map
1716 +
1684 1684  [[image:image-20220830094929-1.png]]
1685 1685  
1719 +Pin Definition Diagram
1720 +
1721 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1722 +
1686 1686  = **MODBUS** =
1687 1687  
1688 1688  == **MODBUS RTU Master** ==
image-20220830140537-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +35.2 KB
Content
image-20220830140629-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content