Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2478,7 +2478,7 @@ 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2480 2480 2481 -== ** 2CommunicationwithWecon LX5V** ==2481 +== **1 HMI and Wecon LX5V serial communication** == 2482 2482 2483 2483 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 ... ... @@ -2511,6 +2511,11 @@ 2511 2511 [[image:image-20220810165759-3.png]] 2512 2512 2513 2513 2514 +**4)Registers list** 2515 + 2516 +[[image:image-20220811102219-3.png]] 2517 + 2518 + 2514 2514 **HMI software configuration** 2515 2515 2516 2516 **1)HMI programming software** ... ... @@ -2525,28 +2525,107 @@ 2525 2525 2526 2526 **3)Set communication port parameters** 2527 2527 2528 - Inthedevice list,findVbox thatcommunicates with the L1769,click itandselectconfiguration,communicationport configuration in themain interface toadd a communicationcol.2533 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2529 2529 2530 - [[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162805-9.png?rev=1.1||alt="image-20220714162805-9.png"]]2535 +Baud rate:115200 2531 2531 2532 - The communication port is selectedas Ethernet, the devicetype is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.2537 +Data bit:8 2533 2533 2534 - [[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162814-10.png?rev=1.1||alt="image-20220714162814-10.png"]]2539 +Stop bit:1 2535 2535 2536 - Afteradding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162827-11.png?rev=1.1||alt="image-20220714162827-11.png"]]2541 +Parity:No verification 2537 2537 2538 -**5)Engineering production** 2539 2539 2540 - Accordingto your own needs, use the V-NET client software to edit the required datamonitoringoints.2544 +[[image:image-20220811104012-1.png]] 2541 2541 2542 -[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162841-12.png?rev=1.1||alt="image-20220714162841-12.png"]] 2543 2543 2544 2544 **hardware connection** 2545 2545 2546 2546 **1)Hardware wiring diagram** 2547 2547 2548 -This V-boxwithAllen-BradleyL1769PLCEthernet.2551 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2549 2549 2550 -[[image: https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162856-13.png?rev=1.1||alt="image-20220714162856-13.png"]]2553 +[[image:image-20220811103005-4.png]] 2551 2551 2552 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 2555 + 2556 +[[image:image-20220811103227-7.png]] 2557 + 2558 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 + 2560 + 2561 +== **2 HMI and Wecon LX5V-N Ethernet communication** == 2562 + 2563 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2564 + 2565 + 2566 +**Software configuration of PLC** 2567 + 2568 +**1)PLC programming software** 2569 + 2570 +[[image:image-20220810164710-1.png]] 2571 + 2572 +**2)New PLC project** 2573 + 2574 +Click New Project and select the PLC model. 2575 + 2576 +[[image:image-20220811115454-1.png]] 2577 + 2578 + 2579 +**3)Set Ethernet port parameters** 2580 + 2581 +Follow the steps below to configure Serial port parameters 2582 + 2583 +PLC IP address:192.168.40.101 2584 + 2585 +default gateway:192.168.40.1 2586 + 2587 +subnet mask:255.255.255.0 2588 + 2589 +[[image:image-20220810165759-3.png]] 2590 + 2591 + 2592 +**4)Registers list** 2593 + 2594 +[[image:image-20220811102219-3.png]] 2595 + 2596 + 2597 +**HMI software configuration** 2598 + 2599 +**1)HMI programming software** 2600 + 2601 + [[image:image-20220810171237-4.png]] 2602 + 2603 +**2)New HMI project** 2604 + 2605 +Click New Project and select the HMI model. 2606 + 2607 +[[image:image-20220810172010-5.png]] 2608 + 2609 +**3)Set communication port parameters** 2610 + 2611 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2612 + 2613 +Baud rate:115200 2614 + 2615 +Data bit:8 2616 + 2617 +Stop bit:1 2618 + 2619 +Parity:No verification 2620 + 2621 + 2622 +[[image:image-20220811104012-1.png]] 2623 + 2624 + 2625 +**hardware connection** 2626 + 2627 +**1)Hardware wiring diagram** 2628 + 2629 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2630 + 2631 +[[image:image-20220811103005-4.png]] 2632 + 2633 + 2634 +[[image:image-20220811103227-7.png]] 2635 + 2636 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
- image-20220811102219-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.8 KB - Content
- image-20220811103005-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.7 KB - Content
- image-20220811103131-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +256.1 KB - Content
- image-20220811103200-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.6 KB - Content
- image-20220811103227-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.0 KB - Content
- image-20220811104012-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +113.6 KB - Content
- image-20220811115454-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +204.7 KB - Content