Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2480,7 +2480,7 @@ 2480 2480 2481 2481 == **2 Communication with Wecon LX5V** == 2482 2482 2483 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.2483 +This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 2485 2485 2486 2486 **Software configuration of PLC** ... ... @@ -2493,7 +2493,7 @@ 2493 2493 2494 2494 Click New Project and select the PLC model. 2495 2495 2496 -[[image:image-202208101 72412-1.png]]2496 +[[image:image-20220810165247-2.png]] 2497 2497 2498 2498 2499 2499 **3)Set Serial port parameters** ... ... @@ -2511,11 +2511,6 @@ 2511 2511 [[image:image-20220810165759-3.png]] 2512 2512 2513 2513 2514 -**4)Registers list** 2515 - 2516 -[[image:image-20220811102219-3.png]] 2517 - 2518 - 2519 2519 **HMI software configuration** 2520 2520 2521 2521 **1)HMI programming software** ... ... @@ -2530,30 +2530,28 @@ 2530 2530 2531 2531 **3)Set communication port parameters** 2532 2532 2533 - Clickthecommunication configurationbutton on thetofindion protocolwithLX5V. Afterselectingthe protocol,configurethearametersofthe COM port.2528 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 2534 2534 2535 - Baud:1152002530 +[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162805-9.png?rev=1.1||alt="image-20220714162805-9.png"]] 2536 2536 2537 - Databit:82532 +The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 2538 2538 2539 - Stop:12534 +[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162814-10.png?rev=1.1||alt="image-20220714162814-10.png"]] 2540 2540 2541 - Parity:No verification2536 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png"]]icon add label.[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162827-11.png?rev=1.1||alt="image-20220714162827-11.png"]] 2542 2542 2543 - [[image:image-20220811093202-2.png]]2538 +**5)Engineering production** 2544 2544 2540 +According to your own needs, use the V-NET client software to edit the required data monitoring points. 2545 2545 2542 +[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162841-12.png?rev=1.1||alt="image-20220714162841-12.png"]] 2546 2546 2547 - 2548 2548 **hardware connection** 2549 2549 2550 2550 **1)Hardware wiring diagram** 2551 2551 2552 -This HMIwithX5VPLCserial port.2548 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: 2553 2553 2554 -[[image:image-2022081110 3005-4.png]]2550 +[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714162856-13.png?rev=1.1||alt="image-20220714162856-13.png"]] 2555 2555 2556 - 2557 -[[image:image-20220811103227-7.png]] 2558 - 2559 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2552 +The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
- image-20220810172412-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -165.3 KB - Content
- image-20220811102219-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -49.8 KB - Content
- image-20220811103005-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -72.7 KB - Content
- image-20220811103131-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -256.1 KB - Content
- image-20220811103200-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.6 KB - Content
- image-20220811103227-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.0 KB - Content