Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 9 removed)
Details
- Page properties
-
- Content
-
... ... @@ -511,7 +511,7 @@ 511 511 (% style="text-align:center" %) 512 512 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 513 514 -== ** CompactLogixFreeTag Ethernetprotocol** ==514 +== **FreeTag Ethernet/IP (CompactLogix)** == 515 515 516 516 Allen-Brandly CompactLogix 517 517 ... ... @@ -568,7 +568,7 @@ 568 568 (% style="text-align:center" %) 569 569 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 570 570 571 -== ** MicroLogix1200** ** protocol** ==571 +== **AB PLC address edit** == 572 572 573 573 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. 574 574 ... ... @@ -1631,195 +1631,242 @@ 1631 1631 1632 1632 **1)HMI Settings** 1633 1633 1634 -|**Item**|**Settings**|**Note** 1635 -|Protocol|DELTA AS300 MODBUS RTU| 1636 -|Connection|RS485| 1637 -|Baud rate|9600| 1638 -|Data bit|8| 1639 -|Parity|NONE| 1640 -|Stop bit|1| 1641 -|PLC station No.|1| 1642 - 1643 1643 **2)Address List** 1644 1644 1636 +**3)Configure the communication protocol** 1645 1645 1646 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1647 -|Bit|X|X|X d|0~~63| 1648 -|Bit|Y|Y|Y d|0~~63| 1649 -|Bit|D|D|D d|0~~29999| 1650 -|Bit|M|M|M d|0~~8191| 1651 -|Bit|SM|SM|SM d|0~~4095| 1652 -|Bit|S|S|S h|0~~2047| 1653 -|Bit|T|T|T d|0~~511| 1654 -|Bit|C|C|C d|0~~511| 1655 -|Bit|HC|HC|HC d|0~~255| 1656 -|Word|X|X|X h|0~~63| 1657 -|Word|Y|Y|Y d|0~~63| 1658 -|Word|SR|SR|SR d|0~~2047| 1659 -|Word|D|D|D d|0~~29999| 1660 -|Word|T|T|T d|0~~511| 1661 -|Word|C|C|C h|0~~511| 1662 -|Word|E|E|E d|0~~9| 1638 +**4)Cable Wiring** 1663 1663 1664 -** 3)Configurethecommunicationprotocol**1640 +== **AS Ethernet Protocol** == 1665 1665 1666 - [[image:image-20220830094600-1.png]]1642 +**1)HMI Settings** 1667 1667 1668 - [[image:image-20220830094657-2.png]]1644 +**2)Address List** 1669 1669 1646 +**3)Configure the communication protocol** 1647 + 1670 1670 **4)Cable Wiring** 1671 1671 1672 - Figure1650 += **MODBUS** = 1673 1673 1674 - [[image:image-20220830141138-1.png]]1652 +== **MODBUS RTU Master** == 1675 1675 1676 - PinDefinitionDiagram1654 +Supported Series: MODBUS RTU CONTROLLER 1677 1677 1678 - [[image:image-20220830095131-1.png]]1656 +HMI works as MODBUS SLAVE connecting with MASTER 1679 1679 1680 -== **AS Ethernet Protocol** == 1658 +(% style="text-align:center" %) 1659 +[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]] 1681 1681 1682 -**1)HMI Settings** 1683 1683 1662 +(% style="text-align:center" %) 1663 +[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1684 1684 1685 -|=**Items**|=**Settings**|=**Note** 1686 -|Protocol|DELTA AS300 MODBUS TCP| 1687 -|Connection|Ethernet| 1688 -|Port No.|502| 1689 -|Device No.|1| 1690 -|HMI No.|0| 1691 1691 1692 -**2)Address List** 1666 +(% style="text-align:center" %) 1667 +[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1693 1693 1669 +**HMI Settings** 1694 1694 1695 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1696 -|Bit|X|X|X d|0~~63| 1697 -|Bit|Y|Y|Y d|0~~63| 1698 -|Bit|D|D|D d|0~~29999| 1699 -|Bit|M|M|M d|0~~8191| 1700 -|Bit|SM|SM|SM d|0~~4095| 1701 -|Bit|S|S|S h|0~~2047| 1702 -|Bit|T|T|T d|0~~511| 1703 -|Bit|C|C|C d|0~~511| 1704 -|Bit|HC|HC|HC d|0~~255| 1705 -|Word|X|X|X h|0~~63| 1706 -|Word|Y|Y|Y d|0~~63| 1707 -|Word|SR|SR|SR d|0~~2047| 1708 -|Word|D|D|D d|0~~29999| 1709 -|Word|T|T|T d|0~~511| 1710 -|Word|C|C|C h|0~~511| 1711 -|Word|E|E|E d|0~~9| 1671 +(% class="table-bordered" %) 1672 +|**Items**|**Settings**|**Note** 1673 +|Protocol|MODBUS RTU Master| 1674 +|Connection|RS485/RS232| 1675 +|Baud rate|2400~~187500| 1676 +|Data bit|8| 1677 +|Parity|Even/ Odd/ None| 1678 +|Stop bit|1/2| 1679 +|Station No.|0~~255| 1712 1712 1713 -** 3)Configurethe communication protocol**1681 +**Address List** 1714 1714 1715 -[[image:image-20220830140537-1.png]] 1683 +(% class="table-bordered" %) 1684 +|**Type**|**HMI address**|**MODBUS code**|**Range** 1685 +|Bit|HDX3000.0~~HDX3499.15|0|0~~7999 1686 +|Word|HDW3500~~HDW7999|4|0~~4499 1716 1716 1717 - [[image:image-20220830140629-2.png]]1688 +**Cable Wiring** 1718 1718 1719 -**4 )Cable Wiring**1690 +* **RS485** 1720 1720 1721 -Figure 1692 +(% style="text-align:center" %) 1693 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 1722 1722 1723 -[[image:image-20220830094929-1.png]] 1695 +(% style="text-align:center" %) 1696 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 1724 1724 1725 - PinDefinition Diagram1698 +* **RS232** 1726 1726 1727 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1700 +(% style="text-align:center" %) 1701 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]] 1728 1728 1729 - = Createcommunicationwith **Omron**PLC=1703 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1730 1730 1731 -== ** CJTCPFINSEthemet Protocol** ==1705 +== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** == 1732 1732 1733 -Supported device:CJ series1707 +Supported Series: MODBUS RTU CONTROLLER 1734 1734 1735 - **1)HMI Settings**1709 +HMI works as MODBUS MASTER connecting with SLAVE. 1736 1736 1737 -|=**Items**|=**Settings**|=**Note** 1738 -|Protocol|OMRON CJ TCP FINS Ethemet| 1739 -|Connection|Ethernet| 1740 -|Port No.|9600| 1741 -|Device No.|0| 1742 -|HMI No.|0|((( 1743 - 1744 -))) 1711 +The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1). 1745 1745 1746 -**2)Address List** 1713 +(% style="text-align:center" %) 1714 +[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]] 1747 1747 1748 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1749 -|Bit|CIO|CIO|CIO d|0~~99999| 1750 -|Bit|W|W|W d|0~~99999| 1751 -|Bit|D|D|D d|0~~99999| 1752 -|Bit|H|H|H d|0~~99999| 1753 -|Bit|A|A|A d|0~~99999| 1754 -|Bit|T|T|T h|0~~99999| 1755 -|Bit|CF|CF|CF d|0~~99999| 1756 -|Bit|FF|FF|FF d|0~~99999| 1757 -|Bit|C|C|C d|0~~99999| 1758 -|Bit|EM0|EM0|EM0 d|0~~99999| 1759 -|Bit|EM1|EM1|EM1 d|0~~99999| 1760 -|Bit|EM2|EM2|EM2 d|0~~99999| 1761 -|Bit|EM3|EM3|EM3 d|0~~99999| 1762 -|Bit|EM4|EM4|EM4 d|0~~99999| 1763 -|Bit|EM5|EM5|EM5 h|0~~99999| 1764 -|Bit|EM6|EM6|EM6 d|0~~99999| 1765 -|Bit|EM7|EM7|EM7 d|0~~99999| 1766 -|Bit|EM8|EM8|EM8 d|0~~99999| 1767 -|Bit|EM9|EM9|EM9 d|0~~99999| 1768 -|Bit|EMA|EMA|EMA d|0~~99999| 1769 -|Bit|EMB|EMB|EMB d|0~~99999| 1770 -|Bit|EMC|EMC|EMC d|0~~99999| 1771 -|Bit|Lamp|Lamp|Lamp d|0~~0| 1772 -|Word|CIO|CIO|CIO d|0~~99999| 1773 -|Word|W|W|W d|0~~99999| 1774 -|Word|D|D|D d|0~~99999| 1775 -|Word|H|H|H d|0~~99999| 1776 -|Word|A|A|A d|0~~99999| 1777 -|Word|T|T|T h|0~~99999| 1778 -|Word|CF|CF|CF d|0~~99999| 1779 -|Word|FF|FF|FF d|0~~99999| 1780 -|Word|C|C|C d|0~~99999| 1781 -|Word|EM0|EM0|EM0 d|0~~99999| 1782 -|Word|EM1|EM1|EM1 d|0~~99999| 1783 -|Word|EM2|EM2|EM2 d|0~~99999| 1784 -|Word|EM3|EM3|EM3 d|0~~99999| 1785 -|Word|EM4|EM4|EM4 d|0~~99999| 1786 -|Word|EM5|EM5|EM5 h|0~~99999| 1787 -|Word|EM6|EM6|EM6 d|0~~99999| 1788 -|Word|EM7|EM7|EM7 d|0~~99999| 1789 -|Word|EM8|EM8|EM8 d|0~~99999| 1790 -|Word|EM9|EM9|EM9 d|0~~99999| 1791 -|Word|EMA|EMA|EMA d|0~~99999| 1792 -|Word|EMB|EMB|EMB d|0~~99999| 1793 -|Word|EMC|EMC|EMC d|0~~99999| 1794 -|Word|IR|IR|IR d|0~~99999| 1795 -|Word|DR|DR|DR d|0~~99999| 1796 1796 1797 -**3)Configure the communication protocol** 1717 +(% style="text-align:center" %) 1718 +[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1798 1798 1799 -[[image:image-20220830143348-1.png]] 1800 1800 1801 -[[image:image-20220830143511-2.png]] 1721 +(% style="text-align:center" %) 1722 +[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1802 1802 1724 +**HMI Settings** 1803 1803 1726 +(% class="table-bordered" %) 1727 +|**Items**|**Settings**|**Note** 1728 +|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)| 1729 +|Connection|RS485/RS232| 1730 +|Baud rate|2400~~187500| 1731 +|Data bit|8| 1732 +|Parity|Even/ Odd/ None| 1733 +|Stop bit|1/2| 1734 +|PLC station No.|0~~255| 1804 1804 1805 -** 4)CableWiring**1736 +**Address List** 1806 1806 1807 -Pin Definition Diagram 1738 +(% class="table-bordered" %) 1739 +|**Type**|**Address Type**|**Function code & Description** 1740 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1741 +|06 (write single register: write a binary value to a holding register) 1742 +|10 (write values to multiple addresses ) 1743 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1744 +|06 (write single register: write a binary value to a holding register) 1745 +|10 (write values to multiple addresses ) 1746 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1747 +|06 (write single register: write a binary value to a holding register) 1748 +|10 (write values to multiple addresses ) 1749 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1750 +|10 (write values to multiple addresses ) 1751 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1752 +|05 (Force a single coil to force the on/off state of a logic coil) 1753 +|0F (Write multiple bits, ie write continuously) 1754 +|(% rowspan="3" %)1|02 (Read the input state) 1755 +|05 (Force a single coil to force the on/off state of a logic coil) 1756 +|0F (Write multiple bits) 1757 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1758 +|05 (Force a single coil to force the on/off state of a logic coil) 1759 +|0F (Write multiple bits) 1760 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1761 +|0F (Write multiple bits) 1808 1808 1809 - [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]1763 +**✎Note:** 1810 1810 1811 - (%class="wikigeneratedid"%)1812 - ====1765 +* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats. 1766 +* The function codes sent out are the same as those that read and write words. 1813 1813 1814 -(% class="wikigeneratedid" %) 1815 -== == 1768 +**Station number for more than one slaves** 1816 1816 1817 - ==**EC55Protocol**==1770 +If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows. 1818 1818 1772 +(% style="text-align:center" %) 1773 +[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]] 1774 + 1775 +**Cable Wiring** 1776 + 1777 +* **RS485** 1778 + 1779 +(% style="text-align:center" %) 1780 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 1781 + 1782 +(% style="text-align:center" %) 1783 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 1784 + 1785 +* **RS232** 1786 + 1787 +(% style="text-align:center" %) 1788 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]] 1789 + 1790 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1791 + 1792 +== **MODBUS TCP Slave (All function)** == 1793 + 1794 +Supported series: MODBUS TCP controller 1795 + 1796 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE 1797 + 1798 +(% style="text-align:center" %) 1799 +[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]] 1800 + 1801 +(% style="text-align:center" %) 1802 +[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]] 1803 + 1804 + 1805 +(% style="text-align:center" %) 1806 +[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]] 1807 + 1808 +**HMI Setting** 1809 + 1810 +(% class="table-bordered" %) 1811 +|**Items**|**Settings**|**Note** 1812 +|Protocol|MODBUS TCP Slave (All function)| 1813 +|Connection|Ethernet| 1814 +|Port No.|502| 1815 +|PLC station No.|1| 1816 + 1817 +**Address List** 1818 + 1819 +(% class="table-bordered" %) 1820 +|**Type**|**Register**|**Function code & Description** 1821 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1822 +|06 (write single register: write a binary value to a holding register) 1823 +|10 (write values to multiple addresses ) 1824 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1825 +|06 (write single register: write a binary value to a holding register) 1826 +|10 (write values to multiple addresses ) 1827 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1828 +|06 (write single register: write a binary value to a holding register) 1829 +|10 (write values to multiple addresses ) 1830 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1831 +|10 (write values to multiple addresses ) 1832 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1833 +|05 (Force a single coil to force the on/off state of a logic coil) 1834 +|0F (Write multiple bits, ie write continuously) 1835 +|(% rowspan="3" %)1|02 (Read the input state) 1836 +|05 (Force a single coil to force the on/off state of a logic coil) 1837 +|0F (Write multiple bits) 1838 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1839 +|05 (Force a single coil to force the on/off state of a logic coil) 1840 +|0F (Write multiple bits) 1841 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1842 +|0F (Write multiple bits) 1843 + 1844 +**Communication Settings** 1845 + 1846 +Enable HMI Ethernet in [Project Settings]; 1847 + 1848 +(% style="text-align:center" %) 1849 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 1850 + 1851 +Set PLC IP in [Device IP] settings; 1852 + 1853 +(% style="text-align:center" %) 1854 +[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 1855 + 1856 +**Cable Wiring** 1857 + 1858 +(% style="text-align:center" %) 1859 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 1860 + 1861 += **Omron** = 1862 + 1863 +== **EC55** == 1864 + 1819 1819 Supported device: EC55 temperature instrument 1820 1820 1821 1821 **HMI Settings** 1822 1822 1869 +(% class="table-bordered" %) 1823 1823 |**Items**|**Settings**|**Note** 1824 1824 |Protocol|Omron EC55| 1825 1825 |Connection|RS485 (9600, 2, 7, EVEN)| ... ... @@ -1828,6 +1828,7 @@ 1828 1828 1829 1829 **Address List** 1830 1830 1878 +(% class="table-bordered" %) 1831 1831 |**Type**|**Register**|**Device range**|**HMI range**|**Function** 1832 1832 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1833 1833 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 ... ... @@ -1873,14 +1873,15 @@ 1873 1873 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1874 1874 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1875 1875 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1876 -* [[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1924 +* (% id="cke_bm_8690S" style="display:none" %)[[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]](%%)Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1877 1877 1878 -== **EtherNet/IP NX seriesProtocol**==1926 +== EtherNet/IP NX series == 1879 1879 1880 1880 Supported series: Omron NX/NJ series 1881 1881 1882 1882 **HMI Setting** 1883 1883 1932 +(% class="table-bordered" %) 1884 1884 |**Items**|**Settings**|**Note** 1885 1885 |Protocol|Omron NX Ethernet/IP| 1886 1886 |Connection|Ethernet| ... ... @@ -1932,224 +1932,183 @@ 1932 1932 (% style="text-align:center" %) 1933 1933 [[image:12.PLC Protocol_html_437cb087b36b5784.png||data-xwiki-image-style-alignment="center" height="330" width="600" class="img-thumbnail"]] 1934 1934 1984 + 1935 1935 (% style="text-align:center" %) 1936 1936 [[image:12.PLC Protocol_html_60ef71528a99abf5.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 1937 1937 1938 1938 **Cable Wiring** 1939 1939 1940 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1941 - 1942 -= **MODBUS** = 1943 - 1944 -== **MODBUS RTU Master** == 1945 - 1946 -Supported Series: MODBUS RTU CONTROLLER 1947 - 1948 -HMI works as MODBUS SLAVE connecting with MASTER 1949 - 1950 1950 (% style="text-align:center" %) 1951 -[[image:12.PLC Protocol_html_ 44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]1991 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 1952 1952 1993 += **OpenCAN** = 1953 1953 1954 -(% style="text-align:center" %) 1955 -[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1995 +OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames. 1956 1956 1997 +This protocol is only available in PI8000 series HMI. 1957 1957 1958 -(% style="text-align:center" %) 1959 -[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 1960 - 1961 1961 **HMI Settings** 1962 1962 1963 1963 (% class="table-bordered" %) 1964 1964 |**Items**|**Settings**|**Note** 1965 -|Protocol|MODBUS RTU Master| 1966 -|Connection|RS485/RS232| 1967 -|Baud rate|2400~~187500| 1968 -|Data bit|8| 1969 -|Parity|Even/ Odd/ None| 1970 -|Stop bit|1/2| 1971 -|Station No.|0~~255| 2003 +|Protocol|OPENCAN| 2004 +|Connection|CAN port| 2005 +|Baud rate|250000| 1972 1972 1973 -**A ddressList**2007 +**CAN frame setting in HMI** 1974 1974 1975 -(% class="table-bordered" %) 1976 -|**Type**|**HMI address**|**MODBUS code**|**Range** 1977 -|Bit|HDX3000.0~~HDX3499.15|0|0~~7999 1978 -|Word|HDW3500~~HDW7999|4|0~~4499 2009 +Click [OpenCAN setting] button in communication setting window; 1979 1979 1980 -**Cable Wiring** 2011 +(% style="text-align:center" %) 2012 +[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]] 1981 1981 1982 - ***RS485**2014 +Click [Add] to create a new frame; 1983 1983 1984 1984 (% style="text-align:center" %) 1985 -[[image:12.PLC Protocol_html_6 8dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]2017 +[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]] 1986 1986 1987 -(% style="text-align:center" %) 1988 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 2019 +(% class="table-bordered" %) 2020 +|**No**|**Items**|**Description** 2021 +|1|Add|add a frame related to register address 2022 +|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position 2023 +|3|Frame manager|This list shows some of the main parameters for each frame that the user adds 2024 +|4|Modify|Modify the frames in frame management 2025 +|5|Copy|Copy one frame to another 2026 +|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted. 2027 +|7|Empty|All frames in the list are cleared 2028 +|8|Browse|Displays configuration files in XML format in IE 2029 +|9|OK|Complete the configuration of the frame and exit 1989 1989 1990 - ***RS232**2031 +Set CANBUS frame in setting windows 1991 1991 1992 1992 (% style="text-align:center" %) 1993 -[[image:12.PLC Protocol_html_ 9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]2034 +[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]] 1994 1994 1995 -**✎Note:** COM3 only available in PI8000/PI9000 series. 2036 +(% class="table-bordered" %) 2037 +|**No**|(% style="width:185px" %)**Items**|(% style="width:854px" %)**Description** 2038 +|1|(% style="width:185px" %)ID|(% style="width:854px" %)Set the ID of a can frame in hexadecimal format; 2039 +|2|(% style="width:185px" %)ID assign|(% style="width:854px" %)split the ID by PF, PS, and SA; 2040 +|3|(% style="width:185px" %)Frame type|(% style="width:854px" %)Select Standard frame or Extended Frame; 2041 +|4|(% style="width:185px" %)Frame format|(% style="width:854px" %)Select between data frame and remote Frame; 2042 +|5|(% style="width:185px" %)Data|(% style="width:854px" %)Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message; 2043 +|6|(% style="width:185px" %)Use address|(% style="width:854px" %)((( 2044 +Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously; 1996 1996 1997 - ==**MODBUSRTUSlave(Allfunction)/(AllfunctionOneBaseAddress)**==2046 +**Edit:** Set a bit or word address by its format; 1998 1998 1999 -Supported Series: MODBUS RTU CONTROLLER 2048 +**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface; 2049 +))) 2050 +|(% rowspan="8" %)7|(% rowspan="8" style="width:185px" %)Data interactive configuration|(% style="width:854px" %)There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback; 2051 +|(% style="width:854px" %)Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way; 2052 +|(% style="width:854px" %)Feedback mode: feedback mode includes no response, confirm response and data response; 2053 +|(% style="width:854px" %)No response: the device or touch screen will not receive feedback; 2054 +|(% style="width:854px" %)Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20; 2055 +|(% style="width:854px" %)Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address; 2056 +|(% style="width:854px" %)response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender; 2057 +|(% style="width:854px" %)Response timeout: sets whether the response frame timeout; 2058 +|(% rowspan="3" %)8|(% rowspan="3" style="width:185px" %)Control address|(% style="width:854px" %)If ticked, enable sending when the value of the corresponding control bit number (address) is non-0. 2059 +|(% style="width:854px" %)Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run; 2060 +|(% style="width:854px" %)Manually send: a manually send tick indicates only one send; 2061 +|9|(% style="width:185px" %)Flag configuration|(% style="width:854px" %)Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal; 2062 +|10|(% style="width:185px" %)Note|(% style="width:854px" %)Fill the text to explain the meaning of the frame; 2063 +|11|(% style="width:185px" %)Data assign|(% style="width:854px" %)Preview the display in this table based on the address and the corresponding number of digits; 2064 +|12|(% style="width:185px" %)Current operation display|(% style="width:854px" %)Display the description of current operation; 2065 +|13|(% style="width:185px" %)Add|(% style="width:854px" %)Add a new frame; 2066 +|14|(% style="width:185px" %)Save frame|(% style="width:854px" %)Save the configured frame format; 2067 +|15|(% style="width:185px" %)Cancel|(% style="width:854px" %)Cancel the frame configuration; 2000 2000 2001 - HMIworksasMODBUS MASTERconnectingwithSLAVE.2069 +Set CAN address (Read or write operation); 2002 2002 2003 -The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1). 2004 - 2005 2005 (% style="text-align:center" %) 2006 -[[image:12.PLC Protocol_html_72 36139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]2072 +[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]] 2007 2007 2074 +(% class="table-bordered" %) 2075 +|**No.**|(% style="width:207px" %)**Item**|(% style="width:829px" %)**Description** 2076 +|1|(% style="width:207px" %)Current address|(% style="width:829px" %)Displays the register type and register address set by the user in the data access interface 2077 +|(% rowspan="3" %)2|(% rowspan="3" style="width:207px" %)Trigger|(% style="width:829px" %)Two operations, "read" and "write," are based on on-screen registers 2078 +|(% style="width:829px" %)If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop. 2079 +|(% style="width:829px" %)If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user. 2080 +|(% rowspan="5" %)3|(% rowspan="3" style="width:207px" %)Data operation|(% style="width:829px" %)The read and write operations in the trigger conditions are set accordingly. 2081 +|(% style="width:829px" %)If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame. 2082 +|(% style="width:829px" %)If the trigger condition is a writing operation, there are two situations:((( 2083 +* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen. 2084 +* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user. 2085 +))) 2086 +|(% rowspan="2" style="width:207px" %)Position and length input format|(% style="width:829px" %)If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on. 2087 +|(% style="width:829px" %)If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on. 2088 +|4|(% style="width:207px" %)Add|(% style="width:829px" %)Add current configuration 2089 +|5|(% style="width:207px" %)Close|(% style="width:829px" %)Close the configuration window to exit 2008 2008 2009 -(% style="text-align:center" %) 2010 -[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]] 2091 +**Multiple Packages Settings** 2011 2011 2012 - 2013 2013 (% style="text-align:center" %) 2014 -[[image:12.PLC Protocol_html_ 4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]2094 +[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]] 2015 2015 2016 - **HMISettings**2096 +Check [Multiple packages supported] to open [Multiple package data] window, as below show. 2017 2017 2018 -(% class="table-bordered" %) 2019 -|**Items**|**Settings**|**Note** 2020 -|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)| 2021 -|Connection|RS485/RS232| 2022 -|Baud rate|2400~~187500| 2023 -|Data bit|8| 2024 -|Parity|Even/ Odd/ None| 2025 -|Stop bit|1/2| 2026 -|PLC station No.|0~~255| 2098 +Select Multiple package type 2027 2027 2028 -**Address List** 2100 +* Not Multiple packages 2101 +* J1939 Multiple packages 2102 +* Customized Multiple packages 2029 2029 2030 -(% class="table-bordered" %) 2031 -|**Type**|**Address Type**|**Function code & Description** 2032 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 2033 -|06 (write single register: write a binary value to a holding register) 2034 -|10 (write values to multiple addresses ) 2035 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 2036 -|06 (write single register: write a binary value to a holding register) 2037 -|10 (write values to multiple addresses ) 2038 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 2039 -|06 (write single register: write a binary value to a holding register) 2040 -|10 (write values to multiple addresses ) 2041 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 2042 -|10 (write values to multiple addresses ) 2043 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 2044 -|05 (Force a single coil to force the on/off state of a logic coil) 2045 -|0F (Write multiple bits, ie write continuously) 2046 -|(% rowspan="3" %)1|02 (Read the input state) 2047 -|05 (Force a single coil to force the on/off state of a logic coil) 2048 -|0F (Write multiple bits) 2049 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 2050 -|05 (Force a single coil to force the on/off state of a logic coil) 2051 -|0F (Write multiple bits) 2052 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 2053 -|0F (Write multiple bits) 2104 +Click [Edit Receive data] for [Receive] settings 2054 2054 2055 -* *✎Note:**2106 +* Start code+ Total length (J1939) 2056 2056 2057 - *Modbuscan also supportgettingbit from the word, which could access the address such as 100.1 and otherformats.2058 - * Thefunctioncodes sentoutarethe sameashosethatread and writewords.2108 +(% style="text-align:center" %) 2109 +[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 2059 2059 2060 - **Stationnumberformore thanone slaves**2111 +As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B; 2061 2061 2062 - Ifthereare morethanone slavesconnectedto HMI, pleasesetslave stationnumberduringeditingaddress, as below shows.2113 +* Start code + Data max length (J1939) 2063 2063 2064 2064 (% style="text-align:center" %) 2065 -[[image:12.PLC Protocol_html_ 31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]2116 +[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 2066 2066 2067 - **CableWiring**2118 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B; 2068 2068 2069 -* **RS485**2120 +* Data max length (J1939) 2070 2070 2071 2071 (% style="text-align:center" %) 2072 -[[image:12.PLC Protocol_html_ 68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]2123 +[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 2073 2073 2074 -(% style="text-align:center" %) 2075 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]] 2125 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes. 2076 2076 2077 -* **RS232**2127 +* Customized multiple package 2078 2078 2079 2079 (% style="text-align:center" %) 2080 -[[image:12.PLC Protocol_html_ 9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]2130 +[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]] 2081 2081 2082 - **✎Note:** COM3onlyavailable inPI8000/PI9000series.2132 +As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes. 2083 2083 2084 - == **MODBUS TCPSlave(Allfunction)** ==2134 +Click [Edit Send data] for [Send] setting 2085 2085 2086 - Supportedseries: MODBUS TCP controller2136 +* J1939 2087 2087 2088 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE 2089 - 2090 2090 (% style="text-align:center" %) 2091 -[[image:12.PLC Protocol_html_ 8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]2139 +[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]] 2092 2092 2093 -(% style="text-align:center" %) 2094 -[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]] 2141 +[Data] is all data to be sent. 2095 2095 2143 +Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes. 2096 2096 2097 -(% style="text-align:center" %) 2098 -[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]] 2145 +* Customized multiple package 2099 2099 2100 -**HMI Setting** 2101 - 2102 -(% class="table-bordered" %) 2103 -|**Items**|**Settings**|**Note** 2104 -|Protocol|MODBUS TCP Slave (All function)| 2105 -|Connection|Ethernet| 2106 -|Port No.|502| 2107 -|PLC station No.|1| 2108 - 2109 -**Address List** 2110 - 2111 -(% class="table-bordered" %) 2112 -|**Type**|**Register**|**Function code & Description** 2113 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 2114 -|06 (write single register: write a binary value to a holding register) 2115 -|10 (write values to multiple addresses ) 2116 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 2117 -|06 (write single register: write a binary value to a holding register) 2118 -|10 (write values to multiple addresses ) 2119 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 2120 -|06 (write single register: write a binary value to a holding register) 2121 -|10 (write values to multiple addresses ) 2122 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 2123 -|10 (write values to multiple addresses ) 2124 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 2125 -|05 (Force a single coil to force the on/off state of a logic coil) 2126 -|0F (Write multiple bits, ie write continuously) 2127 -|(% rowspan="3" %)1|02 (Read the input state) 2128 -|05 (Force a single coil to force the on/off state of a logic coil) 2129 -|0F (Write multiple bits) 2130 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 2131 -|05 (Force a single coil to force the on/off state of a logic coil) 2132 -|0F (Write multiple bits) 2133 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 2134 -|0F (Write multiple bits) 2135 - 2136 -**Communication Settings** 2137 - 2138 -Enable HMI Ethernet in [Project Settings]; 2139 - 2140 2140 (% style="text-align:center" %) 2141 -[[image:12.PLC Protocol_html_4 3b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405"class="img-thumbnail"]]2148 +[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]] 2142 2142 2143 - SetPLCIPin[DeviceIP]settings;2150 +[Data] is all data to be sent. 2144 2144 2145 -(% style="text-align:center" %) 2146 -[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2152 +As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length. 2147 2147 2148 2148 **Cable Wiring** 2149 2149 2150 2150 (% style="text-align:center" %) 2151 -[[image:12.PLC Protocol_html_ 2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]2157 +[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]] 2152 2152 2159 +**✎Note:** The address interval between each frame need to be more than a word address; 2160 + 2153 2153 = **SHIMADEN** = 2154 2154 2155 2155 == **FP23** == ... ... @@ -2949,168 +2949,3 @@ 2949 2949 **Cable Wiring** 2950 2950 2951 2951 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2952 - 2953 - 2954 -= **OpenCAN** = 2955 - 2956 -OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames. 2957 - 2958 -This protocol is only available in PI8000 series HMI. 2959 - 2960 -**HMI Settings** 2961 - 2962 -|**Items**|**Settings**|**Note** 2963 -|Protocol|OPENCAN| 2964 -|Connection|CAN port| 2965 -|Baud rate|250000| 2966 - 2967 -**CAN frame setting in HMI** 2968 - 2969 -Click [OpenCAN setting] button in communication setting window; 2970 - 2971 -(% style="text-align:center" %) 2972 -[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]] 2973 - 2974 -Click [Add] to create a new frame; 2975 - 2976 -(% style="text-align:center" %) 2977 -[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]] 2978 - 2979 -|**No**|**Items**|**Description** 2980 -|1|Add|add a frame related to register address 2981 -|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position 2982 -|3|Frame manager|This list shows some of the main parameters for each frame that the user adds 2983 -|4|Modify|Modify the frames in frame management 2984 -|5|Copy|Copy one frame to another 2985 -|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted. 2986 -|7|Empty|All frames in the list are cleared 2987 -|8|Browse|Displays configuration files in XML format in IE 2988 -|9|OK|Complete the configuration of the frame and exit 2989 - 2990 -Set CANBUS frame in setting windows 2991 - 2992 -(% style="text-align:center" %) 2993 -[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]] 2994 - 2995 -|**No**|**Items**|**Description** 2996 -|1|ID|Set the ID of a can frame in hexadecimal format; 2997 -|2|ID assign|split the ID by PF, PS, and SA; 2998 -|3|Frame type|Select Standard frame or Extended Frame; 2999 -|4|Frame format|Select between data frame and remote Frame; 3000 -|5|Data|Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message; 3001 -|6|Use address|((( 3002 -Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously; 3003 - 3004 -**Edit:** Set a bit or word address by its format; 3005 - 3006 -**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface; 3007 -))) 3008 -|(% rowspan="8" %)7|(% rowspan="8" %)Data interactive configuration|There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback; 3009 -|Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way; 3010 -|Feedback mode: feedback mode includes no response, confirm response and data response; 3011 -|No response: the device or touch screen will not receive feedback; 3012 -|Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20; 3013 -|Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address; 3014 -|response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender; 3015 -|Response timeout: sets whether the response frame timeout; 3016 -|(% rowspan="3" %)8|(% rowspan="3" %)Control address|If ticked, enable sending when the value of the corresponding control bit number (address) is non-0. 3017 -|Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run; 3018 -|Manually send: a manually send tick indicates only one send; 3019 -|9|Flag configuration|Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal; 3020 -|10|Note|Fill the text to explain the meaning of the frame; 3021 -|11|Data assign|Preview the display in this table based on the address and the corresponding number of digits; 3022 -|12|Current operation display|Display the description of current operation; 3023 -|13|Add|Add a new frame; 3024 -|14|Save frame|Save the configured frame format; 3025 -|15|Cancel|Cancel the frame configuration; 3026 - 3027 -Set CAN address (Read or write operation); 3028 - 3029 -(% style="text-align:center" %) 3030 -[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]] 3031 - 3032 -|**No.**|**Item**|**Description** 3033 -|1|Current address|Displays the register type and register address set by the user in the data access interface 3034 -|(% rowspan="3" %)2|(% rowspan="3" %)Trigger|Two operations, "read" and "write," are based on on-screen registers 3035 -|If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop. 3036 -|If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user. 3037 -|(% rowspan="5" %)3|(% rowspan="3" %)Data operation|The read and write operations in the trigger conditions are set accordingly. 3038 -|If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame. 3039 -|If the trigger condition is a writing operation, there are two situations:((( 3040 -* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen. 3041 -* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user. 3042 -))) 3043 -|(% rowspan="2" %)Position and length input format|If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on. 3044 -|If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on. 3045 -|4|Add|Add current configuration 3046 -|5|Close|Close the configuration window to exit 3047 - 3048 -**Multiple Packages Settings** 3049 - 3050 -(% style="text-align:center" %) 3051 -[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]] 3052 - 3053 -Check [Multiple packages supported] to open [Multiple package data] window, as below show. 3054 - 3055 -Select Multiple package type 3056 - 3057 -* Not Multiple packages 3058 -* J1939 Multiple packages 3059 -* Customized Multiple packages 3060 - 3061 -Click [Edit Receive data] for [Receive] settings 3062 - 3063 -* Start code+ Total length (J1939) 3064 - 3065 -(% style="text-align:center" %) 3066 -[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 3067 - 3068 -As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B; 3069 - 3070 -* Start code + Data max length (J1939) 3071 - 3072 -(% style="text-align:center" %) 3073 -[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 3074 - 3075 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B; 3076 - 3077 -* Data max length (J1939) 3078 - 3079 -(% style="text-align:center" %) 3080 -[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]] 3081 - 3082 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes. 3083 - 3084 -* Customized multiple package 3085 - 3086 -(% style="text-align:center" %) 3087 -[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]] 3088 - 3089 -As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes. 3090 - 3091 -Click [Edit Send data] for [Send] setting 3092 - 3093 -* J1939 3094 - 3095 -(% style="text-align:center" %) 3096 -[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]] 3097 - 3098 -[Data] is all data to be sent. 3099 - 3100 -Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes. 3101 - 3102 -* Customized multiple package 3103 - 3104 -(% style="text-align:center" %) 3105 -[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]] 3106 - 3107 -[Data] is all data to be sent. 3108 - 3109 -As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length. 3110 - 3111 -**Cable Wiring** 3112 - 3113 -(% style="text-align:center" %) 3114 -[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]] 3115 - 3116 -**✎Note:** The address interval between each frame need to be more than a word address;
- image-20220830094600-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.4 KB - Content
- image-20220830094657-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -53.4 KB - Content
- image-20220830094929-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -90.4 KB - Content
- image-20220830095131-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.7 KB - Content
- image-20220830140537-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.2 KB - Content
- image-20220830140629-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -48.4 KB - Content
- image-20220830141138-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -82.9 KB - Content
- image-20220830143348-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.9 KB - Content
- image-20220830143511-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.3 KB - Content