Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 135.1
edited by Ben
on 2022/08/30 14:56
Change comment: There is no comment for this version
To version 138.1
edited by Ben
on 2022/08/30 15:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1800,8 +1800,6 @@
1800 1800  
1801 1801  [[image:image-20220830143511-2.png]]
1802 1802  
1803 -
1804 -
1805 1805  **4)Cable Wiring**
1806 1806  
1807 1807  Pin Definition Diagram
... ... @@ -1808,11 +1808,24 @@
1808 1808  
1809 1809  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1810 1810  
1809 +== **CP1E/CP1H serial protocol** ==
1810 +
1811 +Supported device: OMRON CS1(CP1E/CP1H)
1812 +
1813 +**1)HMI Settings**
1814 +
1815 +**2)Address List**
1816 +
1817 +**3)Configure the communication protocol**
1818 +
1819 +**4)Cable Wiring**
1820 +
1821 +
1811 1811  == **EC55 Protocol** ==
1812 1812  
1813 1813  Supported device: EC55 temperature instrument
1814 1814  
1815 -**HMI Settings**
1826 +**1)HMI Settings**
1816 1816  
1817 1817  |**Items**|**Settings**|**Note**
1818 1818  |Protocol|Omron EC55|
... ... @@ -1820,7 +1820,7 @@
1820 1820  |Port No.|None|
1821 1821  |PLC station No.|0|
1822 1822  
1823 -**Address List**
1834 +**2)Address List**
1824 1824  
1825 1825  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1826 1826  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
... ... @@ -1833,7 +1833,7 @@
1833 1833  |CS|-|0-2|Read controller states
1834 1834  |CA|-|0-17|Action command
1835 1835  
1836 -**Device Settings**
1847 +**3)Device Settings**
1837 1837  
1838 1838  Omron E5CC PLC configuration
1839 1839  
... ... @@ -1933,8 +1933,74 @@
1933 1933  
1934 1934  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1935 1935  
1936 -= **MODBUS** =
1947 +(% class="wikigeneratedid" %)
1948 += =
1937 1937  
1950 +(% class="wikigeneratedid" %)
1951 += Create communication with XINJE** PLC** =
1952 +
1953 +== **XC serial protocol** ==
1954 +
1955 +**1)HMI Settings**
1956 +
1957 +**2)Address List**
1958 +
1959 +**3)Configure the communication protocol**
1960 +
1961 +**4)Cable Wiring**
1962 +
1963 +== **XD serial protocol** ==
1964 +
1965 +**1)HMI Settings**
1966 +
1967 +**2)Address List**
1968 +
1969 +**3)Configure the communication protocol**
1970 +
1971 +**4)Cable Wiring**
1972 +
1973 +
1974 += Create communication with XINJE** PLC** =
1975 +
1976 +== **H3U serial protocol** ==
1977 +
1978 +
1979 +**1)HMI Settings**
1980 +
1981 +**2)Address List**
1982 +
1983 +**3)Configure the communication protocol**
1984 +
1985 +**4)Cable Wiring**
1986 +
1987 += Create communication with Panasonic** PLC** =
1988 +
1989 +== **FP serial protocol** ==
1990 +
1991 +**1)HMI Settings**
1992 +
1993 +**2)Address List**
1994 +
1995 +**3)Configure the communication protocol**
1996 +
1997 +**4)Cable Wiring**
1998 +
1999 += Create communication with LS** PLC** =
2000 +
2001 +== **XBG serial protocol** ==
2002 +
2003 +**1)HMI Settings**
2004 +
2005 +**2)Address List**
2006 +
2007 +**3)Configure the communication protocol**
2008 +
2009 +**4)Cable Wiring**
2010 +
2011 +
2012 +
2013 += Create communication with **MODBUS** =
2014 +
1938 1938  == **MODBUS RTU Master** ==
1939 1939  
1940 1940  Supported Series: MODBUS RTU CONTROLLER