... ... @@ -1800,8 +1800,6 @@
1800 1800  
1801 1801  [[image:image-20220830143511-2.png]]
1802 1802  
1803 -
1804 -
1805 1805  **4)Cable Wiring**
1806 1806  
1807 1807  Pin Definition Diagram
... ... @@ -1808,11 +1808,24 @@
1808 1808  
1809 1809  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1810 1810  
1809 +== **CP1E/CP1H serial protocol** ==
1810 +
1811 +Supported device: OMRON CS1(CP1E/CP1H)
1812 +
1813 +**1)HMI Settings**
1814 +
1815 +**2)Address List**
1816 +
1817 +**3)Configure the communication protocol**
1818 +
1819 +**4)Cable Wiring**
1820 +
1821 +
1811 1811  == **EC55 Protocol** ==
1812 1812  
1813 1813  Supported device: EC55 temperature instrument
1814 1814  
1815 -**HMI Settings**
1826 +**1)HMI Settings**
1816 1816  
1817 1817  |**Items**|**Settings**|**Note**
1818 1818  |Protocol|Omron EC55|
... ... @@ -1820,7 +1820,7 @@
1820 1820  |Port No.|None|
1821 1821  |PLC station No.|0|
1822 1822  
1823 -**Address List**
1834 +**2)Address List**
1824 1824  
1825 1825  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1826 1826  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
... ... @@ -1833,7 +1833,7 @@
1833 1833  |CS|-|0-2|Read controller states
1834 1834  |CA|-|0-17|Action command
1835 1835  
1836 -**Device Settings**
1847 +**3)Device Settings**
1837 1837  
1838 1838  Omron E5CC PLC configuration
1839 1839  
... ... @@ -1933,8 +1933,241 @@
1933 1933  
1934 1934  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1935 1935  
1936 -= **MODBUS** =
1947 +(% class="wikigeneratedid" %)
1948 += =
1937 1937  
1950 +(% class="wikigeneratedid" %)
1951 += Create communication with XINJE** PLC** =
1952 +
1953 +== **XC serial protocol** ==
1954 +
1955 +**1)HMI Settings**
1956 +
1957 +**2)Address List**
1958 +
1959 +**3)Configure the communication protocol**
1960 +
1961 +**4)Cable Wiring**
1962 +
1963 +== **XD serial protocol** ==
1964 +
1965 +**1)HMI Settings**
1966 +
1967 +**2)Address List**
1968 +
1969 +**3)Configure the communication protocol**
1970 +
1971 +**4)Cable Wiring**
1972 +
1973 +
1974 += Create communication with XINJE** PLC** =
1975 +
1976 +== **H3U serial protocol** ==
1977 +
1978 +
1979 +**1)HMI Settings**
1980 +
1981 +**2)Address List**
1982 +
1983 +**3)Configure the communication protocol**
1984 +
1985 +**4)Cable Wiring**
1986 +
1987 += Create communication with Panasonic** PLC** =
1988 +
1989 +== **FP serial protocol** ==
1990 +
1991 +**1)HMI Settings**
1992 +
1993 +**2)Address List**
1994 +
1995 +**3)Configure the communication protocol**
1996 +
1997 +**4)Cable Wiring**
1998 +
1999 += Create communication with LS** PLC** =
2000 +
2001 +== **XBG serial protocol** ==
2002 +
2003 +**1)HMI Settings**
2004 +
2005 +**2)Address List**
2006 +
2007 +**3)Configure the communication protocol**
2008 +
2009 +**4)Cable Wiring**
2010 +
2011 +
2012 += **SHIMADEN** =
2013 +
2014 +== **FP23** ==
2015 +
2016 +Supported series: SHIMADEN FP23 series
2017 +
2018 +**HMI Setting**
2019 +
2020 +|**Items**|**Settings**|**Note**
2021 +|Protocol|SHIMADEN FP23 series|
2022 +|Connection|RS485 (9600, 1, 7, EVEN)|
2023 +|Port No.|None|
2024 +|PLC station No.|0|
2025 +
2026 +**Address List**
2027 +
2028 +|**Device address**|**HMI register**|**Address range**|**Type**
2029 +|0040-0043(HEX)|FP040|100064-200067|Read only
2030 +|0100-010B(HEX)|FP100|100256-200267|Read only
2031 +|0110-0142(HEX)|FP110|100272-200322|Read only
2032 +|0182-0252(HEX)|FP182|100386-200594|Write only
2033 +|0280-0281(HEX)|FP280|100640-200641|Read only
2034 +|0300-030B(HEX)|FP300|100768-200779|Read and write
2035 +|0380-039F(HEX)|FP380|100896-200927|Read and write
2036 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
2037 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
2038 +|0600-0670(HEX)|FP600|101536-201814|Read and write
2039 +|0720-0738(HEX)|FP720|101824-201848|Read and write
2040 +|0800-083F(HEX)|FP800|102048-202111|Read and write
2041 +|0900-0952(HEX)|FP900|102304-202386|Read and write
2042 +| |Ctrl|0-2|
2043 +
2044 +**✎Note:**
2045 +
2046 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
2047 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
2048 +* The Ctrl register is used to store the control group number and BCC check mode.
2049 +
2050 +**Ctrl Register Description**
2051 +
2052 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
2053 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
2054 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
2055 +* Ctrl3 reserved
2056 +
2057 +**✎Note:**
2058 +
2059 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
2060 +
2061 +**Cable Wiring**
2062 +
2063 +(% style="text-align:center" %)
2064 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2065 +
2066 +(% style="text-align:center" %)
2067 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2068 +
2069 +**✎Note:** COM3 only available in PI8000/PI9000 series.
2070 +
2071 +== **{{id name="_Toc23422"/}}**SR90 ==
2072 +
2073 +Supported series: SHIMADEN SR90 series
2074 +
2075 +**HMI Setting**
2076 +
2077 +|**Items**|**Settings**|**Note**
2078 +|Protocol|SHIMADEN SR90 protocol|
2079 +|Connection|RS485 (1200, 1, 7, EVEN)|
2080 +|Port No.|None|
2081 +|PLC station No.|0|
2082 +
2083 +**Address List**
2084 +
2085 +|**Device address**|**HMI register**|**Address range**|**Type**
2086 +|0040-0043 (HEX)|SR040|100064-100067|Read only
2087 +|0100-010A(HEX)|SR0100|100256-100266|Read only
2088 +|0182-018C(HEX)|SR0182|100386-100396|Write only
2089 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
2090 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
2091 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
2092 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
2093 +| |Ctrl|0-2|~-~-
2094 +
2095 +**✎Note:**
2096 +
2097 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
2098 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
2099 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
2100 +
2101 +**Ctrl Register Description**
2102 +
2103 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
2104 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
2105 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
2106 +* Ctrl3 reserved
2107 +
2108 +**✎Note:**
2109 +
2110 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
2111 +
2112 +**Cable Wiring**
2113 +
2114 +(% style="text-align:center" %)
2115 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2116 +
2117 +(% style="text-align:center" %)
2118 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2119 +
2120 +**✎Note:** COM3 only available in PI8000/PI9000 series.
2121 +
2122 +== **{{id name="_Toc22635"/}}**MR13 series(standard protocol) ==
2123 +
2124 +Supported series: SHIMADEN MR13 series
2125 +
2126 +**HMI Setting**
2127 +
2128 +|**Items**|**Settings**|**Note**
2129 +|Protocol|SHIMADEN standard protocol|
2130 +|Connection|RS485 (1200, 1, 7, EVEN)|
2131 +|Port No.|None|
2132 +|PLC station No.|0|
2133 +
2134 +**Address List**
2135 +
2136 +|**Device address**|**HMI register**|**Address range**|**Type**
2137 +|0100-010B(HEX)|MR100|100256-300267|Read only
2138 +|0111-0126(HEX)|MR111|100273-300294|Read only
2139 +|0184-0192(HEX)|MR184|100388-300402|Write only
2140 +|0280-0282(HEX)|MR280|100640-300642|Read only
2141 +|0300-030B(HEX)|MR300|100768-300779|Read/write
2142 +|0314-0317(HEX)|MR314|100788-300791|Read/write
2143 +|031A(HEX)|MR31A|100794-300794|Read/write
2144 +|0320-0321(HEX)|MR320|100800-300801|Read/write
2145 +|0400-0504(HEX)|MR400|101024-301284|Read/write
2146 +|0506(HEX)|MR506|101286-301286|Read/write
2147 +|0510-0514(HEX)|MR510|101296-301300|Read/write
2148 +|0516-0524(HEX)|MR516|101302-301316|Read/write
2149 +|0526(HEX)|MR526|101318-301318|Read/write
2150 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
2151 +|~-~-|Ctrl|0-2|~-~-
2152 +
2153 +**✎Note:**
2154 +
2155 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
2156 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
2157 +* The Ctrl register is used to store the control group number and BCC check mode.
2158 +
2159 +**Ctrl Register Description**
2160 +
2161 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
2162 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
2163 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
2164 +* Ctrl3 reserved
2165 +
2166 +**✎Note:**
2167 +
2168 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
2169 +
2170 +**Cable Wiring**
2171 +
2172 +(% style="text-align:center" %)
2173 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2174 +
2175 +(% style="text-align:center" %)
2176 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2177 +
2178 +**✎Note:** COM3 only available in PI8000/PI9000 series.
2179 +
2180 += Create communication with **MODBUS** =
2181 +
1938 1938  == **MODBUS RTU Master** ==
1939 1939  
1940 1940  Supported Series: MODBUS RTU CONTROLLER