Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1945,7 +1945,7 @@ 1945 1945 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1946 1946 1947 1947 (% class="wikigeneratedid" %) 1948 -= 1948 += = 1949 1949 1950 1950 (% class="wikigeneratedid" %) 1951 1951 = Create communication with XINJE** PLC** = ... ... @@ -2009,7 +2009,174 @@ 2009 2009 **4)Cable Wiring** 2010 2010 2011 2011 2012 += **SHIMADEN** = 2012 2012 2014 +== **FP23** == 2015 + 2016 +Supported series: SHIMADEN FP23 series 2017 + 2018 +**HMI Setting** 2019 + 2020 +|**Items**|**Settings**|**Note** 2021 +|Protocol|SHIMADEN FP23 series| 2022 +|Connection|RS485 (9600, 1, 7, EVEN)| 2023 +|Port No.|None| 2024 +|PLC station No.|0| 2025 + 2026 +**Address List** 2027 + 2028 +|**Device address**|**HMI register**|**Address range**|**Type** 2029 +|0040-0043(HEX)|FP040|100064-200067|Read only 2030 +|0100-010B(HEX)|FP100|100256-200267|Read only 2031 +|0110-0142(HEX)|FP110|100272-200322|Read only 2032 +|0182-0252(HEX)|FP182|100386-200594|Write only 2033 +|0280-0281(HEX)|FP280|100640-200641|Read only 2034 +|0300-030B(HEX)|FP300|100768-200779|Read and write 2035 +|0380-039F(HEX)|FP380|100896-200927|Read and write 2036 +|0400-04D7(HEX)|FP400|101024-201239|Read and write 2037 +|0500-05B0(HEX)|FP500|101280-201456|Read and write 2038 +|0600-0670(HEX)|FP600|101536-201814|Read and write 2039 +|0720-0738(HEX)|FP720|101824-201848|Read and write 2040 +|0800-083F(HEX)|FP800|102048-202111|Read and write 2041 +|0900-0952(HEX)|FP900|102304-202386|Read and write 2042 +| |Ctrl|0-2| 2043 + 2044 +**✎Note:** 2045 + 2046 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2047 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23; 2048 +* The Ctrl register is used to store the control group number and BCC check mode. 2049 + 2050 +**Ctrl Register Description** 2051 + 2052 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2053 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2054 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2055 +* Ctrl3 reserved 2056 + 2057 +**✎Note:** 2058 + 2059 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2060 + 2061 +**Cable Wiring** 2062 + 2063 +(% style="text-align:center" %) 2064 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2065 + 2066 +(% style="text-align:center" %) 2067 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2068 + 2069 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2070 + 2071 +== **{{id name="_Toc23422"/}}**SR90 == 2072 + 2073 +Supported series: SHIMADEN SR90 series 2074 + 2075 +**HMI Setting** 2076 + 2077 +|**Items**|**Settings**|**Note** 2078 +|Protocol|SHIMADEN SR90 protocol| 2079 +|Connection|RS485 (1200, 1, 7, EVEN)| 2080 +|Port No.|None| 2081 +|PLC station No.|0| 2082 + 2083 +**Address List** 2084 + 2085 +|**Device address**|**HMI register**|**Address range**|**Type** 2086 +|0040-0043 (HEX)|SR040|100064-100067|Read only 2087 +|0100-010A(HEX)|SR0100|100256-100266|Read only 2088 +|0182-018C(HEX)|SR0182|100386-100396|Write only 2089 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read 2090 +|0500-050B(HEX)|SR0500|101280-101291|Write/read 2091 +|0590-0611(HEX)|SR0590|101424-101553|Write/read 2092 +|0701-0709(HEX)|SR0701|101793-101801|Write/read 2093 +| |Ctrl|0-2|~-~- 2094 + 2095 +**✎Note:** 2096 + 2097 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2098 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90; 2099 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below; 2100 + 2101 +**Ctrl Register Description** 2102 + 2103 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2104 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2105 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2106 +* Ctrl3 reserved 2107 + 2108 +**✎Note:** 2109 + 2110 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2111 + 2112 +**Cable Wiring** 2113 + 2114 +(% style="text-align:center" %) 2115 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2116 + 2117 +(% style="text-align:center" %) 2118 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2119 + 2120 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2121 + 2122 +== **{{id name="_Toc22635"/}}**MR13 series(standard protocol) == 2123 + 2124 +Supported series: SHIMADEN MR13 series 2125 + 2126 +**HMI Setting** 2127 + 2128 +|**Items**|**Settings**|**Note** 2129 +|Protocol|SHIMADEN standard protocol| 2130 +|Connection|RS485 (1200, 1, 7, EVEN)| 2131 +|Port No.|None| 2132 +|PLC station No.|0| 2133 + 2134 +**Address List** 2135 + 2136 +|**Device address**|**HMI register**|**Address range**|**Type** 2137 +|0100-010B(HEX)|MR100|100256-300267|Read only 2138 +|0111-0126(HEX)|MR111|100273-300294|Read only 2139 +|0184-0192(HEX)|MR184|100388-300402|Write only 2140 +|0280-0282(HEX)|MR280|100640-300642|Read only 2141 +|0300-030B(HEX)|MR300|100768-300779|Read/write 2142 +|0314-0317(HEX)|MR314|100788-300791|Read/write 2143 +|031A(HEX)|MR31A|100794-300794|Read/write 2144 +|0320-0321(HEX)|MR320|100800-300801|Read/write 2145 +|0400-0504(HEX)|MR400|101024-301284|Read/write 2146 +|0506(HEX)|MR506|101286-301286|Read/write 2147 +|0510-0514(HEX)|MR510|101296-301300|Read/write 2148 +|0516-0524(HEX)|MR516|101302-301316|Read/write 2149 +|0526(HEX)|MR526|101318-301318|Read/write 2150 +|0580-08C3(HEX)|MR580|101408-302243|Read/write 2151 +|~-~-|Ctrl|0-2|~-~- 2152 + 2153 +**✎Note:** 2154 + 2155 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2156 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13; 2157 +* The Ctrl register is used to store the control group number and BCC check mode. 2158 + 2159 +**Ctrl Register Description** 2160 + 2161 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2162 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR . 2163 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2164 +* Ctrl3 reserved 2165 + 2166 +**✎Note:** 2167 + 2168 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2169 + 2170 +**Cable Wiring** 2171 + 2172 +(% style="text-align:center" %) 2173 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2174 + 2175 +(% style="text-align:center" %) 2176 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2177 + 2178 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2179 + 2013 2013 = Create communication with **MODBUS** = 2014 2014 2015 2015 == **MODBUS RTU Master** == ... ... @@ -2221,180 +2221,6 @@ 2221 2221 (% style="text-align:center" %) 2222 2222 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2223 2223 2224 -= **SHIMADEN** = 2225 - 2226 -== **FP23** == 2227 - 2228 -Supported series: SHIMADEN FP23 series 2229 - 2230 -**HMI Setting** 2231 - 2232 -(% class="table-bordered" %) 2233 -|**Items**|**Settings**|**Note** 2234 -|Protocol|SHIMADEN FP23 series| 2235 -|Connection|RS485 (9600, 1, 7, EVEN)| 2236 -|Port No.|None| 2237 -|PLC station No.|0| 2238 - 2239 -**Address List** 2240 - 2241 -(% class="table-bordered" %) 2242 -|**Device address**|**HMI register**|**Address range**|**Type** 2243 -|0040-0043(HEX)|FP040|100064-200067|Read only 2244 -|0100-010B(HEX)|FP100|100256-200267|Read only 2245 -|0110-0142(HEX)|FP110|100272-200322|Read only 2246 -|0182-0252(HEX)|FP182|100386-200594|Write only 2247 -|0280-0281(HEX)|FP280|100640-200641|Read only 2248 -|0300-030B(HEX)|FP300|100768-200779|Read and write 2249 -|0380-039F(HEX)|FP380|100896-200927|Read and write 2250 -|0400-04D7(HEX)|FP400|101024-201239|Read and write 2251 -|0500-05B0(HEX)|FP500|101280-201456|Read and write 2252 -|0600-0670(HEX)|FP600|101536-201814|Read and write 2253 -|0720-0738(HEX)|FP720|101824-201848|Read and write 2254 -|0800-083F(HEX)|FP800|102048-202111|Read and write 2255 -|0900-0952(HEX)|FP900|102304-202386|Read and write 2256 -| |Ctrl|0-2| 2257 - 2258 -**✎Note:** 2259 - 2260 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2261 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23; 2262 -* The Ctrl register is used to store the control group number and BCC check mode. 2263 - 2264 -**Ctrl Register Description** 2265 - 2266 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2267 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2268 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2269 -* Ctrl3 reserved 2270 - 2271 -**✎Note:** 2272 - 2273 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2274 - 2275 -**Cable Wiring** 2276 - 2277 -(% style="text-align:center" %) 2278 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2279 - 2280 -(% style="text-align:center" %) 2281 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2282 - 2283 -**✎Note:** COM3 only available in PI8000/PI9000 series. 2284 - 2285 -== **{{id name="_Toc23422"/}}SR90** == 2286 - 2287 -Supported series: SHIMADEN SR90 series 2288 - 2289 -**HMI Setting** 2290 - 2291 -(% class="table-bordered" %) 2292 -|**Items**|**Settings**|**Note** 2293 -|Protocol|SHIMADEN SR90 protocol| 2294 -|Connection|RS485 (1200, 1, 7, EVEN)| 2295 -|Port No.|None| 2296 -|PLC station No.|0| 2297 - 2298 -**Address List** 2299 - 2300 -(% class="table-bordered" %) 2301 -|**Device address**|**HMI register**|**Address range**|**Type** 2302 -|0040-0043 (HEX)|SR040|100064-100067|Read only 2303 -|0100-010A(HEX)|SR0100|100256-100266|Read only 2304 -|0182-018C(HEX)|SR0182|100386-100396|Write only 2305 -|0300-04FE(HEX)|SR0300|100768-101278|Write/read 2306 -|0500-050B(HEX)|SR0500|101280-101291|Write/read 2307 -|0590-0611(HEX)|SR0590|101424-101553|Write/read 2308 -|0701-0709(HEX)|SR0701|101793-101801|Write/read 2309 -| |Ctrl|0-2|~-~- 2310 - 2311 -**✎Note:** 2312 - 2313 -* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2314 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90; 2315 -* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below; 2316 - 2317 -**Ctrl Register Description** 2318 - 2319 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2320 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2321 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2322 -* Ctrl3 reserved 2323 - 2324 -**✎Note:** 2325 - 2326 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2327 - 2328 -**Cable Wiring** 2329 - 2330 -(% style="text-align:center" %) 2331 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2332 - 2333 -(% style="text-align:center" %) 2334 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2335 - 2336 -**✎Note:** COM3 only available in PI8000/PI9000 series. 2337 - 2338 -== **{{id name="_Toc22635"/}}MR13 series(standard protocol)** == 2339 - 2340 -Supported series: SHIMADEN MR13 series 2341 - 2342 -**HMI Setting** 2343 - 2344 -(% class="table-bordered" %) 2345 -|**Items**|**Settings**|**Note** 2346 -|Protocol|SHIMADEN standard protocol| 2347 -|Connection|RS485 (1200, 1, 7, EVEN)| 2348 -|Port No.|None| 2349 -|PLC station No.|0| 2350 - 2351 -**Address List** 2352 - 2353 -(% class="table-bordered" %) 2354 -|**Device address**|**HMI register**|**Address range**|**Type** 2355 -|0100-010B(HEX)|MR100|100256-300267|Read only 2356 -|0111-0126(HEX)|MR111|100273-300294|Read only 2357 -|0184-0192(HEX)|MR184|100388-300402|Write only 2358 -|0280-0282(HEX)|MR280|100640-300642|Read only 2359 -|0300-030B(HEX)|MR300|100768-300779|Read/write 2360 -|0314-0317(HEX)|MR314|100788-300791|Read/write 2361 -|031A(HEX)|MR31A|100794-300794|Read/write 2362 -|0320-0321(HEX)|MR320|100800-300801|Read/write 2363 -|0400-0504(HEX)|MR400|101024-301284|Read/write 2364 -|0506(HEX)|MR506|101286-301286|Read/write 2365 -|0510-0514(HEX)|MR510|101296-301300|Read/write 2366 -|0516-0524(HEX)|MR516|101302-301316|Read/write 2367 -|0526(HEX)|MR526|101318-301318|Read/write 2368 -|0580-08C3(HEX)|MR580|101408-302243|Read/write 2369 -|~-~-|Ctrl|0-2|~-~- 2370 - 2371 -**✎Note:** 2372 - 2373 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2374 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13; 2375 -* The Ctrl register is used to store the control group number and BCC check mode. 2376 - 2377 -**Ctrl Register Description** 2378 - 2379 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2380 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR . 2381 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2382 -* Ctrl3 reserved 2383 - 2384 -**✎Note:** 2385 - 2386 -After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2387 - 2388 -**Cable Wiring** 2389 - 2390 -(% style="text-align:center" %) 2391 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2392 - 2393 -(% style="text-align:center" %) 2394 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2395 - 2396 -**✎Note:** COM3 only available in PI8000/PI9000 series. 2397 - 2398 2398 = **User Defined Protocol** = 2399 2399 2400 2400 If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.