Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2478,7 +2478,7 @@ 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2480 2480 2481 -== ** 2CommunicationwithWecon LX5V** ==2481 +== **1. HMI and Wecon LX5V serial communication** == 2482 2482 2483 2483 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 ... ... @@ -2556,3 +2556,77 @@ 2556 2556 [[image:image-20220811103227-7.png]] 2557 2557 2558 2558 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 + 2560 +== **2. HMI and Wecon LX5V-N Ethernet communication** == 2561 + 2562 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2563 + 2564 + 2565 +**Software configuration of PLC** 2566 + 2567 +**1)PLC programming software** 2568 + 2569 +[[image:image-20220810164710-1.png]] 2570 + 2571 +**2)New PLC project** 2572 + 2573 +Click New Project and select the PLC model. 2574 + 2575 +[[image:image-20220811115454-1.png]] 2576 + 2577 + 2578 +**3)Set Ethernet port parameters** 2579 + 2580 +Follow the steps below to configure Ethernet parameters 2581 + 2582 +PLC IP address:192.168.39.200 2583 + 2584 +default gateway:192.168.39.1 2585 + 2586 +subnet mask:255.255.255.0 2587 + 2588 +[[image:image-20220811140530-2.png]] 2589 + 2590 + 2591 +**4)Registers list** 2592 + 2593 +[[image:image-20220811102219-3.png]] 2594 + 2595 + 2596 +**HMI software configuration** 2597 + 2598 +**1)HMI programming software** 2599 + 2600 + [[image:image-20220810171237-4.png]] 2601 + 2602 +**2)New HMI project** 2603 + 2604 +Click New Project and select the HMI model. 2605 + 2606 +[[image:image-20220810172010-5.png]] 2607 + 2608 +**3)Set communication port parameters** 2609 + 2610 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2611 + 2612 +HMI IP address:192.168.39.201 2613 + 2614 +default gateway:192.168.39.1 2615 + 2616 +subnet mask:255.255.255.0 2617 + 2618 +[[image:image-20220811170753-2.png]] 2619 + 2620 +Next, click Communication Settings to configure the IP of the HMI communication object. 2621 + 2622 +[[image:image-20220811163047-1.png]] 2623 + 2624 +**hardware connection** 2625 + 2626 +**1)Hardware wiring diagram** 2627 + 2628 +This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2629 + 2630 +[[image:image-20220811170248-1.png]] 2631 + 2632 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
- image-20220811115454-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +204.7 KB - Content
- image-20220811140308-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.3 KB - Content
- image-20220811140530-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220811163047-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.7 KB - Content
- image-20220811163943-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +153.6 KB - Content
- image-20220811170248-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.7 KB - Content
- image-20220811170753-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content