Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1945,6 +1945,9 @@ 1945 1945 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1946 1946 1947 1947 (% class="wikigeneratedid" %) 1948 += = 1949 + 1950 +(% class="wikigeneratedid" %) 1948 1948 = Create communication with XINJE** PLC** = 1949 1949 1950 1950 == **XC serial protocol** == ... ... @@ -1968,7 +1968,7 @@ 1968 1968 **4)Cable Wiring** 1969 1969 1970 1970 1971 -= Create communication with novance**1974 += Create communication with XINJE** PLC** = 1972 1972 1973 1973 == **H3U serial protocol** == 1974 1974 ... ... @@ -1993,7 +1993,7 @@ 1993 1993 1994 1994 **4)Cable Wiring** 1995 1995 1996 -= Create communication with LS** 1999 += Create communication with LS** PLC** = 1997 1997 1998 1998 == **XBG serial protocol** == 1999 1999 ... ... @@ -2006,57 +2006,6 @@ 2006 2006 **4)Cable Wiring** 2007 2007 2008 2008 2009 -== **XGK FEnet Ethernet protocol** == 2010 - 2011 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2012 - 2013 -**HMI Settings** 2014 - 2015 -|**Items**|**Settings**|**Note** 2016 -|Protocol|LG XGK FEnet(Ethernet)| 2017 -|Connection|Ethernet| 2018 -|Port No.|2004| 2019 - 2020 -**Address List** 2021 - 2022 -|**Type**|**Register**|**Range**|**Format**|**Note** 2023 -|(% rowspan="14" %)Word|P|0~~2047|P d| 2024 -|M|0~~2047|M d| 2025 -|K|0~~2047|K d| 2026 -|F|0~~2047|F d| 2027 -|T|0~~2047|T d| 2028 -|C|0~~2047|C d| 2029 -|Z|0~~127|Z d| 2030 -|S|0~~127|S d| 2031 -|L|0~~11263|L d| 2032 -|N|0~~21503|N d| 2033 -|D|0~~32767|D d| 2034 -|R|0~~32767|R d| 2035 -|ZR|0~~65535|ZR d| 2036 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2037 - 2038 -**✎Note:** 2039 - 2040 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2041 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2042 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 2043 - 2044 -**Communication settings in HMI** 2045 - 2046 -Enable HMI Ethernet in [Project Settings]; 2047 - 2048 -(% style="text-align:center" %) 2049 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2050 - 2051 -Set PLC IP in [Device IP] settings; 2052 - 2053 -(% style="text-align:center" %) 2054 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2055 - 2056 -**Cable Wiring** 2057 - 2058 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 2059 - 2060 2060 = **SHIMADEN** = 2061 2061 2062 2062 == **FP23** == ... ... @@ -2436,6 +2436,180 @@ 2436 2436 (% style="text-align:center" %) 2437 2437 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2438 2438 2391 += **SHIMADEN** = 2392 + 2393 +== **FP23** == 2394 + 2395 +Supported series: SHIMADEN FP23 series 2396 + 2397 +**HMI Setting** 2398 + 2399 +(% class="table-bordered" %) 2400 +|**Items**|**Settings**|**Note** 2401 +|Protocol|SHIMADEN FP23 series| 2402 +|Connection|RS485 (9600, 1, 7, EVEN)| 2403 +|Port No.|None| 2404 +|PLC station No.|0| 2405 + 2406 +**Address List** 2407 + 2408 +(% class="table-bordered" %) 2409 +|**Device address**|**HMI register**|**Address range**|**Type** 2410 +|0040-0043(HEX)|FP040|100064-200067|Read only 2411 +|0100-010B(HEX)|FP100|100256-200267|Read only 2412 +|0110-0142(HEX)|FP110|100272-200322|Read only 2413 +|0182-0252(HEX)|FP182|100386-200594|Write only 2414 +|0280-0281(HEX)|FP280|100640-200641|Read only 2415 +|0300-030B(HEX)|FP300|100768-200779|Read and write 2416 +|0380-039F(HEX)|FP380|100896-200927|Read and write 2417 +|0400-04D7(HEX)|FP400|101024-201239|Read and write 2418 +|0500-05B0(HEX)|FP500|101280-201456|Read and write 2419 +|0600-0670(HEX)|FP600|101536-201814|Read and write 2420 +|0720-0738(HEX)|FP720|101824-201848|Read and write 2421 +|0800-083F(HEX)|FP800|102048-202111|Read and write 2422 +|0900-0952(HEX)|FP900|102304-202386|Read and write 2423 +| |Ctrl|0-2| 2424 + 2425 +**✎Note:** 2426 + 2427 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2428 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23; 2429 +* The Ctrl register is used to store the control group number and BCC check mode. 2430 + 2431 +**Ctrl Register Description** 2432 + 2433 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2434 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2435 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2436 +* Ctrl3 reserved 2437 + 2438 +**✎Note:** 2439 + 2440 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2441 + 2442 +**Cable Wiring** 2443 + 2444 +(% style="text-align:center" %) 2445 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2446 + 2447 +(% style="text-align:center" %) 2448 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2449 + 2450 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2451 + 2452 +== **{{id name="_Toc23422"/}}SR90** == 2453 + 2454 +Supported series: SHIMADEN SR90 series 2455 + 2456 +**HMI Setting** 2457 + 2458 +(% class="table-bordered" %) 2459 +|**Items**|**Settings**|**Note** 2460 +|Protocol|SHIMADEN SR90 protocol| 2461 +|Connection|RS485 (1200, 1, 7, EVEN)| 2462 +|Port No.|None| 2463 +|PLC station No.|0| 2464 + 2465 +**Address List** 2466 + 2467 +(% class="table-bordered" %) 2468 +|**Device address**|**HMI register**|**Address range**|**Type** 2469 +|0040-0043 (HEX)|SR040|100064-100067|Read only 2470 +|0100-010A(HEX)|SR0100|100256-100266|Read only 2471 +|0182-018C(HEX)|SR0182|100386-100396|Write only 2472 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read 2473 +|0500-050B(HEX)|SR0500|101280-101291|Write/read 2474 +|0590-0611(HEX)|SR0590|101424-101553|Write/read 2475 +|0701-0709(HEX)|SR0701|101793-101801|Write/read 2476 +| |Ctrl|0-2|~-~- 2477 + 2478 +**✎Note:** 2479 + 2480 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2481 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90; 2482 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below; 2483 + 2484 +**Ctrl Register Description** 2485 + 2486 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2487 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 2488 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2489 +* Ctrl3 reserved 2490 + 2491 +**✎Note:** 2492 + 2493 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2494 + 2495 +**Cable Wiring** 2496 + 2497 +(% style="text-align:center" %) 2498 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2499 + 2500 +(% style="text-align:center" %) 2501 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2502 + 2503 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2504 + 2505 +== **{{id name="_Toc22635"/}}MR13 series(standard protocol)** == 2506 + 2507 +Supported series: SHIMADEN MR13 series 2508 + 2509 +**HMI Setting** 2510 + 2511 +(% class="table-bordered" %) 2512 +|**Items**|**Settings**|**Note** 2513 +|Protocol|SHIMADEN standard protocol| 2514 +|Connection|RS485 (1200, 1, 7, EVEN)| 2515 +|Port No.|None| 2516 +|PLC station No.|0| 2517 + 2518 +**Address List** 2519 + 2520 +(% class="table-bordered" %) 2521 +|**Device address**|**HMI register**|**Address range**|**Type** 2522 +|0100-010B(HEX)|MR100|100256-300267|Read only 2523 +|0111-0126(HEX)|MR111|100273-300294|Read only 2524 +|0184-0192(HEX)|MR184|100388-300402|Write only 2525 +|0280-0282(HEX)|MR280|100640-300642|Read only 2526 +|0300-030B(HEX)|MR300|100768-300779|Read/write 2527 +|0314-0317(HEX)|MR314|100788-300791|Read/write 2528 +|031A(HEX)|MR31A|100794-300794|Read/write 2529 +|0320-0321(HEX)|MR320|100800-300801|Read/write 2530 +|0400-0504(HEX)|MR400|101024-301284|Read/write 2531 +|0506(HEX)|MR506|101286-301286|Read/write 2532 +|0510-0514(HEX)|MR510|101296-301300|Read/write 2533 +|0516-0524(HEX)|MR516|101302-301316|Read/write 2534 +|0526(HEX)|MR526|101318-301318|Read/write 2535 +|0580-08C3(HEX)|MR580|101408-302243|Read/write 2536 +|~-~-|Ctrl|0-2|~-~- 2537 + 2538 +**✎Note:** 2539 + 2540 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 2541 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13; 2542 +* The Ctrl register is used to store the control group number and BCC check mode. 2543 + 2544 +**Ctrl Register Description** 2545 + 2546 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 2547 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR . 2548 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 2549 +* Ctrl3 reserved 2550 + 2551 +**✎Note:** 2552 + 2553 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 2554 + 2555 +**Cable Wiring** 2556 + 2557 +(% style="text-align:center" %) 2558 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2559 + 2560 +(% style="text-align:center" %) 2561 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2562 + 2563 +**✎Note:** COM3 only available in PI8000/PI9000 series. 2564 + 2439 2439 = **User Defined Protocol** = 2440 2440 2441 2441 If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands. ... ... @@ -3009,6 +3009,60 @@ 3009 3009 (% style="text-align:center" %) 3010 3010 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 3011 3011 3138 += **LG XGK FEnet Ethernet** = 3139 + 3140 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 3141 + 3142 +**HMI Settings** 3143 + 3144 +(% class="table-bordered" %) 3145 +|**Items**|**Settings**|**Note** 3146 +|Protocol|LG XGK FEnet(Ethernet)| 3147 +|Connection|Ethernet| 3148 +|Port No.|2004| 3149 + 3150 +**Address List** 3151 + 3152 +(% class="table-bordered" %) 3153 +|**Type**|**Register**|**Range**|**Format**|**Note** 3154 +|(% rowspan="14" %)Word|P|0~~2047|P d| 3155 +|M|0~~2047|M d| 3156 +|K|0~~2047|K d| 3157 +|F|0~~2047|F d| 3158 +|T|0~~2047|T d| 3159 +|C|0~~2047|C d| 3160 +|Z|0~~127|Z d| 3161 +|S|0~~127|S d| 3162 +|L|0~~11263|L d| 3163 +|N|0~~21503|N d| 3164 +|D|0~~32767|D d| 3165 +|R|0~~32767|R d| 3166 +|ZR|0~~65535|ZR d| 3167 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 3168 + 3169 +**✎Note:** 3170 + 3171 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 3172 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 3173 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 3174 + 3175 +**Communication settings in HMI** 3176 + 3177 +Enable HMI Ethernet in [Project Settings]; 3178 + 3179 +(% style="text-align:center" %) 3180 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3181 + 3182 +Set PLC IP in [Device IP] settings; 3183 + 3184 +(% style="text-align:center" %) 3185 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 3186 + 3187 +**Cable Wiring** 3188 + 3189 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 3190 + 3191 + 3012 3012 = **OpenCAN** = 3013 3013 3014 3014 OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.