Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
From version 17.1
edited by Ben
on 2022/08/11 16:22
on 2022/08/11 16:22
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Hunter - Content
-
... ... @@ -1993,17 +1993,28 @@ 1993 1993 1994 1994 == **S7-XXX Ethernet** == 1995 1995 1996 -Supported Series: Siemens S7-1200 and S7-1500 1996 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 1997 1997 1998 1998 **HMI Setting** 1999 1999 2000 -(% class="table-bordered" %) 2001 -|**Items**|**Settings**|**Note** 2002 -|Protocol|Siemens S7-XXX| 2003 -|Connection|Ethernet| 2004 -|Port No.|102| 2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 2000 +(% class="table-bordered" style="width:823px" %) 2001 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2002 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2003 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2004 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2005 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2006 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2006 2006 2008 +Slot from TIA Portal is equal to Device No. of PIStudio 2009 + 2010 +Rack from TIA Portal is equal to HMI No. of PIStudio 2011 + 2012 +(% style="text-align:center" %) 2013 +[[image:S7-XXXCommunication Settings.png]] 2014 + 2015 +(% style="text-align:center" %) 2016 +[[image:S7-XXXCommunication SettingsPI.png]] 2017 + 2007 2007 **Address List** 2008 2008 2009 2009 (% class="table-bordered" %) ... ... @@ -2478,7 +2478,7 @@ 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2480 2480 2481 -== **1 HMI and Wecon LX5V serial communication** == 2492 +== **1. HMI and Wecon LX5V serial communication** == 2482 2482 2483 2483 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 ... ... @@ -2557,9 +2557,8 @@ 2557 2557 2558 2558 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 2559 2571 +== **2. HMI and Wecon LX5V-N Ethernet communication** == 2560 2560 2561 -== **2 HMI and Wecon LX5V-N Ethernet communication** == 2562 - 2563 2563 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2564 2564 2565 2565 ... ... @@ -2608,29 +2608,26 @@ 2608 2608 2609 2609 **3)Set communication port parameters** 2610 2610 2611 -Click the communicationconfiguration button on the left to findthecommunicationprotocolwithLX5V. Afterselecting theprotocol,configure thecommunicationparametersof the COM port.2621 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2612 2612 2613 - Baudate:1152002623 +HMI IP address:192.168.39.201 2614 2614 2615 - Databit:82625 +default gateway:192.168.39.1 2616 2616 2617 - Stopbit:12627 +subnet mask:255.255.255.0 2618 2618 2619 - Parity:No verification2629 +[[image:image-20220811170753-2.png]] 2620 2620 2631 +Next, click Communication Settings to configure the IP of the HMI communication object. 2621 2621 2622 -[[image:image-20220811104 012-1.png]]2633 +[[image:image-20220811163047-1.png]] 2623 2623 2624 - 2625 2625 **hardware connection** 2626 2626 2627 2627 **1)Hardware wiring diagram** 2628 2628 2629 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:2639 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2630 2630 2631 -[[image:image-2022081110 3005-4.png]]2641 +[[image:image-20220811170248-1.png]] 2632 2632 2633 - 2634 -[[image:image-20220811103227-7.png]] 2635 - 2636 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2643 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- image-20220811163047-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.7 KB - Content
- image-20220811163943-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +153.6 KB - Content
- image-20220811170248-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.7 KB - Content
- image-20220811170753-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content