Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2478,7 +2478,7 @@ 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2480 2480 2481 -== **1 HMI and Wecon LX5V serial communication** == 2481 +== **1. HMI and Wecon LX5V serial communication** == 2482 2482 2483 2483 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 ... ... @@ -2557,7 +2557,6 @@ 2557 2557 2558 2558 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 2559 2560 - 2561 2561 == **2. HMI and Wecon LX5V-N Ethernet communication** == 2562 2562 2563 2563 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. ... ... @@ -2608,19 +2608,18 @@ 2608 2608 2609 2609 **3)Set communication port parameters** 2610 2610 2611 -Click the project setting button on the left to configure the IP address of the HMI machine ,and maintain a local area networkwith the PLC IP.2610 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2612 2612 2613 - PLCIP address:192.168.39.2012612 +HMI IP address:192.168.39.201 2614 2614 2615 2615 default gateway:192.168.39.1 2616 2616 2617 2617 subnet mask:255.255.255.0 2618 2618 2619 -[[image:image-202208111 63943-2.png]]2618 +[[image:image-20220811170753-2.png]] 2620 2620 2621 2621 Next, click Communication Settings to configure the IP of the HMI communication object. 2622 2622 2623 - 2624 2624 [[image:image-20220811163047-1.png]] 2625 2625 2626 2626 **hardware connection** ... ... @@ -2627,9 +2627,8 @@ 2627 2627 2628 2628 **1)Hardware wiring diagram** 2629 2629 2630 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:2628 +This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2631 2631 2630 +[[image:image-20220811170248-1.png]] 2632 2632 2633 - 2634 - 2635 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2632 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
- image-20220811170248-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.7 KB - Content
- image-20220811170753-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content