Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
From version 18.1
edited by Ben
on 2022/08/11 16:53
on 2022/08/11 16:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Stone - Content
-
... ... @@ -1896,7 +1896,7 @@ 1896 1896 1897 1897 == **LOGO Ethernet** == 1898 1898 1899 -Supported Series: Siemens Logo 1899 +Supported Series: Siemens Logo 0BA0 series 1900 1900 1901 1901 **HMI Settings** 1902 1902 ... ... @@ -1959,9 +1959,8 @@ 1959 1959 Set PLC IP in [Device IP] settings; 1960 1960 1961 1961 (% style="text-align:center" %) 1962 -[[image: 12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]1962 +[[image:SiemensLOGODeviceIP.png]] 1963 1963 1964 - 1965 1965 Enable HMI Ethernet in [Project Settings]; 1966 1966 1967 1967 (% style="text-align:center" %) ... ... @@ -1993,17 +1993,28 @@ 1993 1993 1994 1994 == **S7-XXX Ethernet** == 1995 1995 1996 -Supported Series: Siemens S7-1200 and S7-1500 1995 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 1997 1997 1998 1998 **HMI Setting** 1999 1999 2000 -(% class="table-bordered" %) 2001 -|**Items**|**Settings**|**Note** 2002 -|Protocol|Siemens S7-XXX| 2003 -|Connection|Ethernet| 2004 -|Port No.|102| 2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 1999 +(% class="table-bordered" style="width:823px" %) 2000 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2001 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2002 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2003 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2004 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2005 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2006 2006 2007 +Slot from TIA Portal is equal to Device No. of PIStudio 2008 + 2009 +Rack from TIA Portal is equal to HMI No. of PIStudio 2010 + 2011 +(% style="text-align:center" %) 2012 +[[image:S7-XXXCommunication Settings.png]] 2013 + 2014 +(% style="text-align:center" %) 2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 2016 + 2007 2007 **Address List** 2008 2008 2009 2009 (% class="table-bordered" %) ... ... @@ -2477,12 +2477,10 @@ 2477 2477 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2490 +== HMI and Wecon LX5V serial communication == 2480 2480 2481 -== **1 HMI and Wecon LX5V serial communication** == 2482 - 2483 2483 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2484 2484 2485 - 2486 2486 **Software configuration of PLC** 2487 2487 2488 2488 **1)PLC programming software** ... ... @@ -2557,9 +2557,8 @@ 2557 2557 2558 2558 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 2559 2568 +== HMI and Wecon LX5V-N Ethernet communication == 2560 2560 2561 -== **2. HMI and Wecon LX5V-N Ethernet communication** == 2562 - 2563 2563 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2564 2564 2565 2565 ... ... @@ -2608,19 +2608,18 @@ 2608 2608 2609 2609 **3)Set communication port parameters** 2610 2610 2611 -Click the project setting button on the left to configure the IP address of the HMI machine ,and maintain a local area networkwith the PLC IP.2618 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2612 2612 2613 - PLCIP address:192.168.39.2012620 +HMI IP address:192.168.39.201 2614 2614 2615 2615 default gateway:192.168.39.1 2616 2616 2617 2617 subnet mask:255.255.255.0 2618 2618 2619 -[[image:image-202208111 63943-2.png]]2626 +[[image:image-20220811170753-2.png]] 2620 2620 2621 2621 Next, click Communication Settings to configure the IP of the HMI communication object. 2622 2622 2623 - 2624 2624 [[image:image-20220811163047-1.png]] 2625 2625 2626 2626 **hardware connection** ... ... @@ -2627,9 +2627,10 @@ 2627 2627 2628 2628 **1)Hardware wiring diagram** 2629 2629 2630 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:2636 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2631 2631 2638 +[[image:image-20220811170248-1.png]] 2632 2632 2640 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2633 2633 2634 - 2635 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2642 += **Schneider MODBUS RTU** =
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- S7-XXXCommunication SettingsPIStudio.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- SiemensLOGODeviceIP.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220811170248-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.7 KB - Content
- image-20220811170753-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content