Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 20.1
edited by Ben
on 2022/08/11 17:11
Change comment: There is no comment for this version
To version 24.1
edited by Hunter
on 2022/08/15 10:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Hunter
Content
... ... @@ -1993,17 +1993,28 @@
1993 1993  
1994 1994  == **S7-XXX Ethernet** ==
1995 1995  
1996 -Supported Series: Siemens S7-1200 and S7-1500
1996 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
1997 1997  
1998 1998  **HMI Setting**
1999 1999  
2000 -(% class="table-bordered" %)
2001 -|**Items**|**Settings**|**Note**
2002 -|Protocol|Siemens S7-XXX|
2003 -|Connection|Ethernet|
2004 -|Port No.|102|
2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
2000 +(% class="table-bordered" style="width:823px" %)
2001 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2002 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2003 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2004 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2005 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2006 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2006 2006  
2008 +Slot from TIA Portal is equal to Device No. of PIStudio
2009 +
2010 +Rack from TIA Portal is equal to HMI No. of PIStudio
2011 +
2012 +(% style="text-align:center" %)
2013 +[[image:S7-XXXCommunication Settings.png]]
2014 +
2015 +(% style="text-align:center" %)
2016 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2017 +
2007 2007  **Address List**
2008 2008  
2009 2009  (% class="table-bordered" %)
... ... @@ -2478,7 +2478,7 @@
2478 2478  **✎Note:** COM3 only available in PI8000/PI9000 series.
2479 2479  
2480 2480  
2481 -== **1 HMI and Wecon LX5V serial communication** ==
2492 +== **1. HMI and Wecon LX5V serial communication** ==
2482 2482  
2483 2483  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2484 2484  
... ... @@ -2557,7 +2557,6 @@
2557 2557  
2558 2558  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2559 2559  
2560 -
2561 2561  == **2. HMI and Wecon LX5V-N Ethernet communication** ==
2562 2562  
2563 2563  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
... ... @@ -2626,7 +2626,7 @@
2626 2626  
2627 2627  **1)Hardware wiring diagram**
2628 2628  
2629 -This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows:
2639 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2630 2630  
2631 2631  [[image:image-20220811170248-1.png]]
2632 2632  
S7-XXXCommunication Settings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
S7-XXXCommunication SettingsPI.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
S7-XXXCommunication SettingsPIStudio.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content