Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1896,7 +1896,7 @@ 1896 1896 1897 1897 == **LOGO Ethernet** == 1898 1898 1899 -Supported Series: Siemens Logo 1899 +Supported Series: Siemens Logo 0BA0 series 1900 1900 1901 1901 **HMI Settings** 1902 1902 ... ... @@ -1959,9 +1959,8 @@ 1959 1959 Set PLC IP in [Device IP] settings; 1960 1960 1961 1961 (% style="text-align:center" %) 1962 -[[image: 12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]1962 +[[image:SiemensLOGODeviceIP.png]] 1963 1963 1964 - 1965 1965 Enable HMI Ethernet in [Project Settings]; 1966 1966 1967 1967 (% style="text-align:center" %) ... ... @@ -1993,17 +1993,28 @@ 1993 1993 1994 1994 == **S7-XXX Ethernet** == 1995 1995 1996 -Supported Series: Siemens S7-1200 and S7-1500 1995 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 1997 1997 1998 1998 **HMI Setting** 1999 1999 2000 -(% class="table-bordered" %) 2001 -|**Items**|**Settings**|**Note** 2002 -|Protocol|Siemens S7-XXX| 2003 -|Connection|Ethernet| 2004 -|Port No.|102| 2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 1999 +(% class="table-bordered" style="width:823px" %) 2000 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2001 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2002 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2003 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2004 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2005 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2006 2006 2007 +Slot from TIA Portal is equal to Device No. of PIStudio 2008 + 2009 +Rack from TIA Portal is equal to HMI No. of PIStudio 2010 + 2011 +(% style="text-align:center" %) 2012 +[[image:S7-XXXCommunication Settings.png]] 2013 + 2014 +(% style="text-align:center" %) 2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 2016 + 2007 2007 **Address List** 2008 2008 2009 2009 (% class="table-bordered" %) ... ... @@ -2310,6 +2310,160 @@ 2310 2310 2311 2311 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 2312 2312 2323 + 2324 +== HMI and Wecon LX5V serial communication == 2325 + 2326 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2327 + 2328 +**Software configuration of PLC** 2329 + 2330 +**1)PLC programming software** 2331 + 2332 +[[image:image-20220810164710-1.png]] 2333 + 2334 +**2)New PLC project** 2335 + 2336 +Click New Project and select the PLC model. 2337 + 2338 +[[image:image-20220810172412-1.png]] 2339 + 2340 + 2341 +**3)Set Serial port parameters** 2342 + 2343 +Follow the steps below to configure Serial port parameters 2344 + 2345 +Baud rate:115200 2346 + 2347 +Data bit:8 2348 + 2349 +Stop bit:1 2350 + 2351 +Parity:No verification 2352 + 2353 +[[image:image-20220810165759-3.png]] 2354 + 2355 + 2356 +**4)Registers list** 2357 + 2358 +[[image:image-20220811102219-3.png]] 2359 + 2360 + 2361 +**HMI software configuration** 2362 + 2363 +**1)HMI programming software** 2364 + 2365 + [[image:image-20220810171237-4.png]] 2366 + 2367 +**2)New HMI project** 2368 + 2369 +Click New Project and select the HMI model. 2370 + 2371 +[[image:image-20220810172010-5.png]] 2372 + 2373 +**3)Set communication port parameters** 2374 + 2375 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2376 + 2377 +Baud rate:115200 2378 + 2379 +Data bit:8 2380 + 2381 +Stop bit:1 2382 + 2383 +Parity:No verification 2384 + 2385 + 2386 +[[image:image-20220811104012-1.png]] 2387 + 2388 + 2389 +**hardware connection** 2390 + 2391 +**1)Hardware wiring diagram** 2392 + 2393 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2394 + 2395 +[[image:image-20220811103005-4.png]] 2396 + 2397 + 2398 +[[image:image-20220811103227-7.png]] 2399 + 2400 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2401 + 2402 +== HMI and Wecon LX5V-N Ethernet communication == 2403 + 2404 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2405 + 2406 + 2407 +**Software configuration of PLC** 2408 + 2409 +**1)PLC programming software** 2410 + 2411 +[[image:image-20220810164710-1.png]] 2412 + 2413 +**2)New PLC project** 2414 + 2415 +Click New Project and select the PLC model. 2416 + 2417 +[[image:image-20220811115454-1.png]] 2418 + 2419 + 2420 +**3)Set Ethernet port parameters** 2421 + 2422 +Follow the steps below to configure Ethernet parameters 2423 + 2424 +PLC IP address:192.168.39.200 2425 + 2426 +default gateway:192.168.39.1 2427 + 2428 +subnet mask:255.255.255.0 2429 + 2430 +[[image:image-20220811140530-2.png]] 2431 + 2432 + 2433 +**4)Registers list** 2434 + 2435 +[[image:image-20220811102219-3.png]] 2436 + 2437 + 2438 +**HMI software configuration** 2439 + 2440 +**1)HMI programming software** 2441 + 2442 + [[image:image-20220810171237-4.png]] 2443 + 2444 +**2)New HMI project** 2445 + 2446 +Click New Project and select the HMI model. 2447 + 2448 +[[image:image-20220810172010-5.png]] 2449 + 2450 +**3)Set communication port parameters** 2451 + 2452 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2453 + 2454 +HMI IP address:192.168.39.201 2455 + 2456 +default gateway:192.168.39.1 2457 + 2458 +subnet mask:255.255.255.0 2459 + 2460 +[[image:image-20220811170753-2.png]] 2461 + 2462 +Next, click Communication Settings to configure the IP of the HMI communication object. 2463 + 2464 +[[image:image-20220811163047-1.png]] 2465 + 2466 +**hardware connection** 2467 + 2468 +**1)Hardware wiring diagram** 2469 + 2470 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2471 + 2472 +[[image:image-20220811170248-1.png]] 2473 + 2474 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2475 + 2476 + 2313 2313 = **Printer** = 2314 2314 2315 2315 == **TSPL label printer** == ... ... @@ -2478,156 +2478,35 @@ 2478 2478 **✎Note:** COM3 only available in PI8000/PI9000 series. 2479 2479 2480 2480 2481 -= =**1 HMI and WeconLX5V serialcommunication** ==2645 += **Schneider MODBUS RTU** = 2482 2482 2483 - This example introduces the establishment of serial port communication between WeconHMIand LX5V. It is introducedthroughthree parts: PLC software configuration, HMI software configuration, and hardware wiring.2647 +**HMI Setting** 2484 2484 2649 +|=**Parameters**|=**Recommended**|=**Notes** 2650 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 2651 +|Connection|RS485| 2652 +|**Baud rate**|19200| 2653 +|**Data bit**|8| 2654 +|**Parity**|Even| 2655 +|**Stop bit**|1| 2656 +|**PLC station No.**|1| 2485 2485 2486 -**S oftwareconfigurationof PLC**2658 +**PLC Setting** 2487 2487 2488 - **1)PLCprogrammingsoftware**2660 +|=(% scope="row" %)**Communication mode**|Modbus RTU protocol 2489 2489 2490 - [[image:image-20220810164710-1.png]]2662 +**Device Address** 2491 2491 2492 -**2)New PLC project** 2664 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 2665 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 2666 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 2667 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 2668 +|W|MW|DDDDDD|0 ~~ 999999|Output register 2669 +|DW|MD|DDDDDD|0 ~~ 999999|Output register 2493 2493 2494 - Click New Project andselect the PLCmodel.2671 +**Wiring Diagram** 2495 2495 2496 - [[image:image-20220810172412-1.png]]2673 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 2497 2497 2498 - 2499 -**3)Set Serial port parameters** 2500 - 2501 -Follow the steps below to configure Serial port parameters 2502 - 2503 -Baud rate:115200 2504 - 2505 -Data bit:8 2506 - 2507 -Stop bit:1 2508 - 2509 -Parity:No verification 2510 - 2511 -[[image:image-20220810165759-3.png]] 2512 - 2513 - 2514 -**4)Registers list** 2515 - 2516 -[[image:image-20220811102219-3.png]] 2517 - 2518 - 2519 -**HMI software configuration** 2520 - 2521 -**1)HMI programming software** 2522 - 2523 - [[image:image-20220810171237-4.png]] 2524 - 2525 -**2)New HMI project** 2526 - 2527 -Click New Project and select the HMI model. 2528 - 2529 -[[image:image-20220810172010-5.png]] 2530 - 2531 -**3)Set communication port parameters** 2532 - 2533 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2534 - 2535 -Baud rate:115200 2536 - 2537 -Data bit:8 2538 - 2539 -Stop bit:1 2540 - 2541 -Parity:No verification 2542 - 2543 - 2544 -[[image:image-20220811104012-1.png]] 2545 - 2546 - 2547 -**hardware connection** 2548 - 2549 -**1)Hardware wiring diagram** 2550 - 2551 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2552 - 2553 -[[image:image-20220811103005-4.png]] 2554 - 2555 - 2556 -[[image:image-20220811103227-7.png]] 2557 - 2558 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2559 - 2560 - 2561 -== **2. HMI and Wecon LX5V-N Ethernet communication** == 2562 - 2563 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2564 - 2565 - 2566 -**Software configuration of PLC** 2567 - 2568 -**1)PLC programming software** 2569 - 2570 -[[image:image-20220810164710-1.png]] 2571 - 2572 -**2)New PLC project** 2573 - 2574 -Click New Project and select the PLC model. 2575 - 2576 -[[image:image-20220811115454-1.png]] 2577 - 2578 - 2579 -**3)Set Ethernet port parameters** 2580 - 2581 -Follow the steps below to configure Ethernet parameters 2582 - 2583 -PLC IP address:192.168.39.200 2584 - 2585 -default gateway:192.168.39.1 2586 - 2587 -subnet mask:255.255.255.0 2588 - 2589 -[[image:image-20220811140530-2.png]] 2590 - 2591 - 2592 -**4)Registers list** 2593 - 2594 -[[image:image-20220811102219-3.png]] 2595 - 2596 - 2597 -**HMI software configuration** 2598 - 2599 -**1)HMI programming software** 2600 - 2601 - [[image:image-20220810171237-4.png]] 2602 - 2603 -**2)New HMI project** 2604 - 2605 -Click New Project and select the HMI model. 2606 - 2607 -[[image:image-20220810172010-5.png]] 2608 - 2609 -**3)Set communication port parameters** 2610 - 2611 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2612 - 2613 -HMI IP address:192.168.39.201 2614 - 2615 -default gateway:192.168.39.1 2616 - 2617 -subnet mask:255.255.255.0 2618 - 2619 -[[image:image-20220811170753-2.png]] 2620 - 2621 -Next, click Communication Settings to configure the IP of the HMI communication object. 2622 - 2623 -[[image:image-20220811163047-1.png]] 2624 - 2625 -**hardware connection** 2626 - 2627 -**1)Hardware wiring diagram** 2628 - 2629 -This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2630 - 2631 -[[image:image-20220811170248-1.png]] 2632 - 2633 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2675 +(% style="text-align:center" %) 2676 +[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- S7-XXXCommunication SettingsPIStudio.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- SiemensLOGODeviceIP.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220817154212-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.8 KB - Content