Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
From version 21.1
edited by Ben
on 2022/08/11 17:13
on 2022/08/11 17:13
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Hunter - Content
-
... ... @@ -1896,7 +1896,7 @@ 1896 1896 1897 1897 == **LOGO Ethernet** == 1898 1898 1899 -Supported Series: Siemens Logo 1899 +Supported Series: Siemens Logo 0BA0 series 1900 1900 1901 1901 **HMI Settings** 1902 1902 ... ... @@ -1959,9 +1959,8 @@ 1959 1959 Set PLC IP in [Device IP] settings; 1960 1960 1961 1961 (% style="text-align:center" %) 1962 -[[image: 12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]1962 +[[image:SiemensLOGODeviceIP.png]] 1963 1963 1964 - 1965 1965 Enable HMI Ethernet in [Project Settings]; 1966 1966 1967 1967 (% style="text-align:center" %) ... ... @@ -1993,17 +1993,28 @@ 1993 1993 1994 1994 == **S7-XXX Ethernet** == 1995 1995 1996 -Supported Series: Siemens S7-1200 and S7-1500 1995 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 1997 1997 1998 1998 **HMI Setting** 1999 1999 2000 -(% class="table-bordered" %) 2001 -|**Items**|**Settings**|**Note** 2002 -|Protocol|Siemens S7-XXX| 2003 -|Connection|Ethernet| 2004 -|Port No.|102| 2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 1999 +(% class="table-bordered" style="width:823px" %) 2000 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2001 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2002 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2003 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2004 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2005 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2006 2006 2007 +Slot from TIA Portal is equal to Device No. of PIStudio 2008 + 2009 +Rack from TIA Portal is equal to HMI No. of PIStudio 2010 + 2011 +(% style="text-align:center" %) 2012 +[[image:S7-XXXCommunication Settings.png]] 2013 + 2014 +(% style="text-align:center" %) 2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 2016 + 2007 2007 **Address List** 2008 2008 2009 2009 (% class="table-bordered" %) ... ... @@ -2625,7 +2625,7 @@ 2625 2625 2626 2626 **1)Hardware wiring diagram** 2627 2627 2628 -This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2638 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2629 2629 2630 2630 [[image:image-20220811170248-1.png]] 2631 2631
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- S7-XXXCommunication SettingsPIStudio.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- SiemensLOGODeviceIP.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content