Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 22.1
edited by Ben
on 2022/08/11 17:14
Change comment: There is no comment for this version
To version 26.1
edited by Stone Wu
on 2022/08/17 15:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Stone
Content
... ... @@ -1896,7 +1896,7 @@
1896 1896  
1897 1897  == **LOGO Ethernet** ==
1898 1898  
1899 -Supported Series: Siemens Logo
1899 +Supported Series: Siemens Logo 0BA0 series
1900 1900  
1901 1901  **HMI Settings**
1902 1902  
... ... @@ -1959,9 +1959,8 @@
1959 1959  Set PLC IP in [Device IP] settings;
1960 1960  
1961 1961  (% style="text-align:center" %)
1962 -[[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]
1962 +[[image:SiemensLOGODeviceIP.png]]
1963 1963  
1964 -
1965 1965  Enable HMI Ethernet in [Project Settings];
1966 1966  
1967 1967  (% style="text-align:center" %)
... ... @@ -1993,17 +1993,28 @@
1993 1993  
1994 1994  == **S7-XXX Ethernet** ==
1995 1995  
1996 -Supported Series: Siemens S7-1200 and S7-1500
1995 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
1997 1997  
1998 1998  **HMI Setting**
1999 1999  
2000 -(% class="table-bordered" %)
2001 -|**Items**|**Settings**|**Note**
2002 -|Protocol|Siemens S7-XXX|
2003 -|Connection|Ethernet|
2004 -|Port No.|102|
2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
1999 +(% class="table-bordered" style="width:823px" %)
2000 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2001 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2002 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2003 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2004 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2005 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2006 2006  
2007 +Slot from TIA Portal is equal to Device No. of PIStudio
2008 +
2009 +Rack from TIA Portal is equal to HMI No. of PIStudio
2010 +
2011 +(% style="text-align:center" %)
2012 +[[image:S7-XXXCommunication Settings.png]]
2013 +
2014 +(% style="text-align:center" %)
2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2016 +
2007 2007  **Address List**
2008 2008  
2009 2009  (% class="table-bordered" %)
... ... @@ -2477,12 +2477,10 @@
2477 2477  
2478 2478  **✎Note:** COM3 only available in PI8000/PI9000 series.
2479 2479  
2490 +== HMI and Wecon LX5V serial communication ==
2480 2480  
2481 -== **1. HMI and Wecon LX5V serial communication** ==
2482 -
2483 2483  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2484 2484  
2485 -
2486 2486  **Software configuration of PLC**
2487 2487  
2488 2488  **1)PLC programming software**
... ... @@ -2557,7 +2557,7 @@
2557 2557  
2558 2558  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2559 2559  
2560 -== **2. HMI and Wecon LX5V-N Ethernet communication** ==
2568 +== HMI and Wecon LX5V-N Ethernet communication ==
2561 2561  
2562 2562  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2563 2563  
... ... @@ -2630,3 +2630,5 @@
2630 2630  [[image:image-20220811170248-1.png]]
2631 2631  
2632 2632  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2641 +
2642 += **Schneider MODBUS RTU** =
S7-XXXCommunication Settings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
S7-XXXCommunication SettingsPI.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
S7-XXXCommunication SettingsPIStudio.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
SiemensLOGODeviceIP.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content