Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 22.1
edited by Ben
on 2022/08/11 17:14
Change comment: There is no comment for this version
To version 37.1
edited by Ben
on 2022/08/20 16:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1896,7 +1896,7 @@
1896 1896  
1897 1897  == **LOGO Ethernet** ==
1898 1898  
1899 -Supported Series: Siemens Logo
1899 +Supported Series: Siemens Logo 0BA0 series
1900 1900  
1901 1901  **HMI Settings**
1902 1902  
... ... @@ -1959,9 +1959,8 @@
1959 1959  Set PLC IP in [Device IP] settings;
1960 1960  
1961 1961  (% style="text-align:center" %)
1962 -[[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]
1962 +[[image:SiemensLOGODeviceIP.png]]
1963 1963  
1964 -
1965 1965  Enable HMI Ethernet in [Project Settings];
1966 1966  
1967 1967  (% style="text-align:center" %)
... ... @@ -1993,17 +1993,28 @@
1993 1993  
1994 1994  == **S7-XXX Ethernet** ==
1995 1995  
1996 -Supported Series: Siemens S7-1200 and S7-1500
1995 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
1997 1997  
1998 1998  **HMI Setting**
1999 1999  
2000 -(% class="table-bordered" %)
2001 -|**Items**|**Settings**|**Note**
2002 -|Protocol|Siemens S7-XXX|
2003 -|Connection|Ethernet|
2004 -|Port No.|102|
2005 -|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
1999 +(% class="table-bordered" style="width:823px" %)
2000 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2001 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2002 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2003 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2004 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2005 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2006 2006  
2007 +Slot from TIA Portal is equal to Device No. of PIStudio
2008 +
2009 +Rack from TIA Portal is equal to HMI No. of PIStudio
2010 +
2011 +(% style="text-align:center" %)
2012 +[[image:S7-XXXCommunication Settings.png]]
2013 +
2014 +(% style="text-align:center" %)
2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2016 +
2007 2007  **Address List**
2008 2008  
2009 2009  (% class="table-bordered" %)
... ... @@ -2293,9 +2293,6 @@
2293 2293  * **RS485**
2294 2294  
2295 2295  (% style="text-align:center" %)
2296 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2297 -
2298 -(% style="text-align:center" %)
2299 2299  [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2300 2300  
2301 2301  * **RS422**
... ... @@ -2310,6 +2310,159 @@
2310 2310  
2311 2311  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2312 2312  
2320 +
2321 +== **HMI and Wecon LX5V serial communication** ==
2322 +
2323 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2324 +
2325 +**Software configuration of PLC**
2326 +
2327 +**1)PLC programming software**
2328 +
2329 +[[image:image-20220810164710-1.png]]
2330 +
2331 +**2)New PLC project**
2332 +
2333 +Click New Project and select the PLC model.
2334 +
2335 +[[image:image-20220810172412-1.png]]
2336 +
2337 +
2338 +**3)Set Serial port parameters**
2339 +
2340 +Follow the steps below to configure Serial port parameters
2341 +
2342 +Baud rate:115200
2343 +
2344 +Data bit:8
2345 +
2346 +Stop bit:1
2347 +
2348 +Parity:No verification
2349 +
2350 +[[image:image-20220810165759-3.png]]
2351 +
2352 +
2353 +**4)Registers list**
2354 +
2355 +[[image:image-20220811102219-3.png]]
2356 +
2357 +
2358 +**HMI software configuration**
2359 +
2360 +**1)HMI programming software**
2361 +
2362 + [[image:image-20220810171237-4.png]]
2363 +
2364 +**2)New HMI project**
2365 +
2366 +Click New Project and select the HMI model.
2367 +
2368 +[[image:image-20220810172010-5.png]]
2369 +
2370 +**3)Set communication port parameters**
2371 +
2372 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2373 +
2374 +Baud rate:115200
2375 +
2376 +Data bit:8
2377 +
2378 +Stop bit:1
2379 +
2380 +Parity:No verification
2381 +
2382 +
2383 +[[image:image-20220811104012-1.png]]
2384 +
2385 +
2386 +**hardware connection**
2387 +
2388 +**1)Hardware wiring diagram**
2389 +
2390 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2391 +
2392 +[[image:image-20220811103005-4.png]]
2393 +
2394 +
2395 +[[image:image-20220811103227-7.png]]
2396 +
2397 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2398 +
2399 +== **HMI and Wecon LX5V-N Ethernet communication** ==
2400 +
2401 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2402 +
2403 +
2404 +**Software configuration of PLC**
2405 +
2406 +**1)PLC programming software**
2407 +
2408 +[[image:image-20220810164710-1.png]]
2409 +
2410 +**2)New PLC project**
2411 +
2412 +Click New Project and select the PLC model.
2413 +
2414 +[[image:image-20220811115454-1.png]]
2415 +
2416 +
2417 +**3)Set Ethernet port parameters**
2418 +
2419 +Follow the steps below to configure Ethernet parameters
2420 +
2421 +PLC IP address:192.168.39.200
2422 +
2423 +default gateway:192.168.39.1
2424 +
2425 +subnet mask:255.255.255.0
2426 +
2427 +[[image:image-20220811140530-2.png]]
2428 +
2429 +
2430 +**4)Registers list**
2431 +
2432 +[[image:image-20220811102219-3.png]]
2433 +
2434 +
2435 +**HMI software configuration**
2436 +
2437 +**1)HMI programming software**
2438 +
2439 + [[image:image-20220810171237-4.png]]
2440 +
2441 +**2)New HMI project**
2442 +
2443 +Click New Project and select the HMI model.
2444 +
2445 +[[image:image-20220810172010-5.png]]
2446 +
2447 +**3)Set communication port parameters**
2448 +
2449 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2450 +
2451 +HMI IP address:192.168.39.201
2452 +
2453 +default gateway:192.168.39.1
2454 +
2455 +subnet mask:255.255.255.0
2456 +
2457 +[[image:image-20220811170753-2.png]]
2458 +
2459 +Next, click Communication Settings to configure the IP of the HMI communication object.
2460 +
2461 +[[image:image-20220811163047-1.png]]
2462 +
2463 +**hardware connection**
2464 +
2465 +**1)Hardware wiring diagram**
2466 +
2467 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2468 +
2469 +[[image:image-20220811170248-1.png]]
2470 +
2471 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2472 +
2313 2313  = **Printer** =
2314 2314  
2315 2315  == **TSPL label printer** ==
... ... @@ -2478,155 +2478,35 @@
2478 2478  **✎Note:** COM3 only available in PI8000/PI9000 series.
2479 2479  
2480 2480  
2481 -== **1. HMI and Wecon LX5V serial communication** ==
2641 += **Schneider MODBUS RTU** =
2482 2482  
2483 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2643 +**HMI Setting**
2484 2484  
2645 +|=**Parameters**|=**Recommended**|=**Notes**
2646 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
2647 +|Connection|RS485|
2648 +|**Baud rate**|19200|
2649 +|**Data bit**|8|
2650 +|**Parity**|Even|
2651 +|**Stop bit**|1|
2652 +|**PLC station No.**|1|
2485 2485  
2486 -**Software configuration of PLC**
2654 +**PLC Setting**
2487 2487  
2488 -**1)PLC programming software**
2656 +|=(% scope="row" %)**Communication mode**|Modbus RTU protocol
2489 2489  
2490 -[[image:image-20220810164710-1.png]]
2658 +**Device Address**
2491 2491  
2492 -**2)New PLC project**
2660 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2661 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2662 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
2663 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2664 +|W|MW|DDDDDD|0 ~~ 999999|Output register
2665 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
2493 2493  
2494 -Click New Project and select the PLC model.
2667 +**Wiring Diagram**
2495 2495  
2496 -[[image:image-20220810172412-1.png]]
2669 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
2497 2497  
2498 -
2499 -**3)Set Serial port parameters**
2500 -
2501 -Follow the steps below to configure Serial port parameters
2502 -
2503 -Baud rate:115200
2504 -
2505 -Data bit:8
2506 -
2507 -Stop bit:1
2508 -
2509 -Parity:No verification
2510 -
2511 -[[image:image-20220810165759-3.png]]
2512 -
2513 -
2514 -**4)Registers list**
2515 -
2516 -[[image:image-20220811102219-3.png]]
2517 -
2518 -
2519 -**HMI software configuration**
2520 -
2521 -**1)HMI programming software**
2522 -
2523 - [[image:image-20220810171237-4.png]]
2524 -
2525 -**2)New HMI project**
2526 -
2527 -Click New Project and select the HMI model.
2528 -
2529 -[[image:image-20220810172010-5.png]]
2530 -
2531 -**3)Set communication port parameters**
2532 -
2533 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2534 -
2535 -Baud rate:115200
2536 -
2537 -Data bit:8
2538 -
2539 -Stop bit:1
2540 -
2541 -Parity:No verification
2542 -
2543 -
2544 -[[image:image-20220811104012-1.png]]
2545 -
2546 -
2547 -**hardware connection**
2548 -
2549 -**1)Hardware wiring diagram**
2550 -
2551 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2552 -
2553 -[[image:image-20220811103005-4.png]]
2554 -
2555 -
2556 -[[image:image-20220811103227-7.png]]
2557 -
2558 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2559 -
2560 -== **2. HMI and Wecon LX5V-N Ethernet communication** ==
2561 -
2562 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2563 -
2564 -
2565 -**Software configuration of PLC**
2566 -
2567 -**1)PLC programming software**
2568 -
2569 -[[image:image-20220810164710-1.png]]
2570 -
2571 -**2)New PLC project**
2572 -
2573 -Click New Project and select the PLC model.
2574 -
2575 -[[image:image-20220811115454-1.png]]
2576 -
2577 -
2578 -**3)Set Ethernet port parameters**
2579 -
2580 -Follow the steps below to configure Ethernet parameters
2581 -
2582 -PLC IP address:192.168.39.200
2583 -
2584 -default gateway:192.168.39.1
2585 -
2586 -subnet mask:255.255.255.0
2587 -
2588 -[[image:image-20220811140530-2.png]]
2589 -
2590 -
2591 -**4)Registers list**
2592 -
2593 -[[image:image-20220811102219-3.png]]
2594 -
2595 -
2596 -**HMI software configuration**
2597 -
2598 -**1)HMI programming software**
2599 -
2600 - [[image:image-20220810171237-4.png]]
2601 -
2602 -**2)New HMI project**
2603 -
2604 -Click New Project and select the HMI model.
2605 -
2606 -[[image:image-20220810172010-5.png]]
2607 -
2608 -**3)Set communication port parameters**
2609 -
2610 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2611 -
2612 -HMI IP address:192.168.39.201
2613 -
2614 -default gateway:192.168.39.1
2615 -
2616 -subnet mask:255.255.255.0
2617 -
2618 -[[image:image-20220811170753-2.png]]
2619 -
2620 -Next, click Communication Settings to configure the IP of the HMI communication object.
2621 -
2622 -[[image:image-20220811163047-1.png]]
2623 -
2624 -**hardware connection**
2625 -
2626 -**1)Hardware wiring diagram**
2627 -
2628 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2629 -
2630 -[[image:image-20220811170248-1.png]]
2631 -
2632 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2671 +(% style="text-align:center" %)
2672 +[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
S7-XXXCommunication Settings.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
S7-XXXCommunication SettingsPI.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
S7-XXXCommunication SettingsPIStudio.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
SiemensLOGODeviceIP.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220817154212-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +51.8 KB
Content