Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Ben - Content
-
... ... @@ -1993,28 +1993,17 @@ 1993 1993 1994 1994 == **S7-XXX Ethernet** == 1995 1995 1996 -Supported Series: Siemens S7- 400, S7-1200 and S7-15001996 +Supported Series: Siemens S7-1200 and S7-1500 1997 1997 1998 1998 **HMI Setting** 1999 1999 2000 -(% class="table-bordered" style="width:823px" %) 2001 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2002 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2003 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2004 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2005 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2006 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2000 +(% class="table-bordered" %) 2001 +|**Items**|**Settings**|**Note** 2002 +|Protocol|Siemens S7-XXX| 2003 +|Connection|Ethernet| 2004 +|Port No.|102| 2005 +|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 2007 2007 2008 -Slot from TIA Portal is equal to Device No. of PIStudio 2009 - 2010 -Rack from TIA Portal is equal to HMI No. of PIStudio 2011 - 2012 -(% style="text-align:center" %) 2013 -[[image:S7-XXXCommunication Settings.png]] 2014 - 2015 -(% style="text-align:center" %) 2016 -[[image:S7-XXXCommunication SettingsPI.png]] 2017 - 2018 2018 **Address List** 2019 2019 2020 2020 (% class="table-bordered" %) ... ... @@ -2489,7 +2489,7 @@ 2489 2489 **✎Note:** COM3 only available in PI8000/PI9000 series. 2490 2490 2491 2491 2492 -== **1 .HMI and Wecon LX5V serial communication** ==2481 +== **1 HMI and Wecon LX5V serial communication** == 2493 2493 2494 2494 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2495 2495 ... ... @@ -2568,6 +2568,7 @@ 2568 2568 2569 2569 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2570 2570 2560 + 2571 2571 == **2. HMI and Wecon LX5V-N Ethernet communication** == 2572 2572 2573 2573 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. ... ... @@ -2636,7 +2636,7 @@ 2636 2636 2637 2637 **1)Hardware wiring diagram** 2638 2638 2639 -This example introduces WeconHMI with LX5V -NPLC to establish communication through ethernet. The connection diagram is as follows:2629 +This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2640 2640 2641 2641 [[image:image-20220811170248-1.png]] 2642 2642
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content