Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -1896,7 +1896,7 @@ 1896 1896 1897 1897 == **LOGO Ethernet** == 1898 1898 1899 -Supported Series: Siemens Logo 1899 +Supported Series: Siemens Logo 0BA0 series 1900 1900 1901 1901 **HMI Settings** 1902 1902 ... ... @@ -1959,9 +1959,8 @@ 1959 1959 Set PLC IP in [Device IP] settings; 1960 1960 1961 1961 (% style="text-align:center" %) 1962 -[[image: 12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]1962 +[[image:SiemensLOGODeviceIP.png]] 1963 1963 1964 - 1965 1965 Enable HMI Ethernet in [Project Settings]; 1966 1966 1967 1967 (% style="text-align:center" %) ... ... @@ -2013,7 +2013,7 @@ 2013 2013 [[image:S7-XXXCommunication Settings.png]] 2014 2014 2015 2015 (% style="text-align:center" %) 2016 -[[image:S7-XXXCommunication SettingsPI.png]] 2015 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 2017 2017 2018 2018 **Address List** 2019 2019 ... ... @@ -2488,12 +2488,10 @@ 2488 2488 2489 2489 **✎Note:** COM3 only available in PI8000/PI9000 series. 2490 2490 2490 +== HMI and Wecon LX5V serial communication == 2491 2491 2492 -== **1. HMI and Wecon LX5V serial communication** == 2493 - 2494 2494 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2495 2495 2496 - 2497 2497 **Software configuration of PLC** 2498 2498 2499 2499 **1)PLC programming software** ... ... @@ -2568,7 +2568,7 @@ 2568 2568 2569 2569 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2570 2570 2571 -== **2.HMI and Wecon LX5V-N Ethernet communication**==2568 +== HMI and Wecon LX5V-N Ethernet communication == 2572 2572 2573 2573 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2574 2574 ... ... @@ -2641,3 +2641,5 @@ 2641 2641 [[image:image-20220811170248-1.png]] 2642 2642 2643 2643 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2641 + 2642 += **Schneider MODBUS RTU** =
- S7-XXXCommunication SettingsPIStudio.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- SiemensLOGODeviceIP.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content