Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 24.1
edited by Hunter
on 2022/08/15 10:57
Change comment: There is no comment for this version
To version 21.1
edited by Ben
on 2022/08/11 17:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Ben
Content
... ... @@ -1993,28 +1993,17 @@
1993 1993  
1994 1994  == **S7-XXX Ethernet** ==
1995 1995  
1996 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
1996 +Supported Series: Siemens S7-1200 and S7-1500
1997 1997  
1998 1998  **HMI Setting**
1999 1999  
2000 -(% class="table-bordered" style="width:823px" %)
2001 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2002 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2003 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2004 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2005 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2006 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2000 +(% class="table-bordered" %)
2001 +|**Items**|**Settings**|**Note**
2002 +|Protocol|Siemens S7-XXX|
2003 +|Connection|Ethernet|
2004 +|Port No.|102|
2005 +|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
2007 2007  
2008 -Slot from TIA Portal is equal to Device No. of PIStudio
2009 -
2010 -Rack from TIA Portal is equal to HMI No. of PIStudio
2011 -
2012 -(% style="text-align:center" %)
2013 -[[image:S7-XXXCommunication Settings.png]]
2014 -
2015 -(% style="text-align:center" %)
2016 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2017 -
2018 2018  **Address List**
2019 2019  
2020 2020  (% class="table-bordered" %)
... ... @@ -2636,7 +2636,7 @@
2636 2636  
2637 2637  **1)Hardware wiring diagram**
2638 2638  
2639 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2628 +This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows:
2640 2640  
2641 2641  [[image:image-20220811170248-1.png]]
2642 2642  
S7-XXXCommunication Settings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -32.6 KB
Content
S7-XXXCommunication SettingsPI.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
S7-XXXCommunication SettingsPIStudio.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content