Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 25.1
edited by Hunter
on 2022/08/15 17:09
Change comment: There is no comment for this version
To version 14.1
edited by Ben
on 2022/08/11 10:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Ben
Content
... ... @@ -1896,7 +1896,7 @@
1896 1896  
1897 1897  == **LOGO Ethernet** ==
1898 1898  
1899 -Supported Series: Siemens Logo 0BA0 series
1899 +Supported Series: Siemens Logo
1900 1900  
1901 1901  **HMI Settings**
1902 1902  
... ... @@ -1959,8 +1959,9 @@
1959 1959  Set PLC IP in [Device IP] settings;
1960 1960  
1961 1961  (% style="text-align:center" %)
1962 -[[image:SiemensLOGODeviceIP.png]]
1962 +[[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]
1963 1963  
1964 +
1964 1964  Enable HMI Ethernet in [Project Settings];
1965 1965  
1966 1966  (% style="text-align:center" %)
... ... @@ -1992,28 +1992,17 @@
1992 1992  
1993 1993  == **S7-XXX Ethernet** ==
1994 1994  
1995 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
1996 +Supported Series: Siemens S7-1200 and S7-1500
1996 1996  
1997 1997  **HMI Setting**
1998 1998  
1999 -(% class="table-bordered" style="width:823px" %)
2000 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2001 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2002 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2003 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2004 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2005 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2000 +(% class="table-bordered" %)
2001 +|**Items**|**Settings**|**Note**
2002 +|Protocol|Siemens S7-XXX|
2003 +|Connection|Ethernet|
2004 +|Port No.|102|
2005 +|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)|
2006 2006  
2007 -Slot from TIA Portal is equal to Device No. of PIStudio
2008 -
2009 -Rack from TIA Portal is equal to HMI No. of PIStudio
2010 -
2011 -(% style="text-align:center" %)
2012 -[[image:S7-XXXCommunication Settings.png]]
2013 -
2014 -(% style="text-align:center" %)
2015 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2016 -
2017 2017  **Address List**
2018 2018  
2019 2019  (% class="table-bordered" %)
... ... @@ -2488,7 +2488,7 @@
2488 2488  **✎Note:** COM3 only available in PI8000/PI9000 series.
2489 2489  
2490 2490  
2491 -== **1. HMI and Wecon LX5V serial communication** ==
2481 +== **2 Communication with Wecon LX5V** ==
2492 2492  
2493 2493  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2494 2494  
... ... @@ -2566,77 +2566,3 @@
2566 2566  [[image:image-20220811103227-7.png]]
2567 2567  
2568 2568  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2569 -
2570 -== **2. HMI and Wecon LX5V-N Ethernet communication** ==
2571 -
2572 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2573 -
2574 -
2575 -**Software configuration of PLC**
2576 -
2577 -**1)PLC programming software**
2578 -
2579 -[[image:image-20220810164710-1.png]]
2580 -
2581 -**2)New PLC project**
2582 -
2583 -Click New Project and select the PLC model.
2584 -
2585 -[[image:image-20220811115454-1.png]]
2586 -
2587 -
2588 -**3)Set Ethernet port parameters**
2589 -
2590 -Follow the steps below to configure Ethernet parameters
2591 -
2592 -PLC IP address:192.168.39.200
2593 -
2594 -default gateway:192.168.39.1
2595 -
2596 -subnet mask:255.255.255.0
2597 -
2598 -[[image:image-20220811140530-2.png]]
2599 -
2600 -
2601 -**4)Registers list**
2602 -
2603 -[[image:image-20220811102219-3.png]]
2604 -
2605 -
2606 -**HMI software configuration**
2607 -
2608 -**1)HMI programming software**
2609 -
2610 - [[image:image-20220810171237-4.png]]
2611 -
2612 -**2)New HMI project**
2613 -
2614 -Click New Project and select the HMI model.
2615 -
2616 -[[image:image-20220810172010-5.png]]
2617 -
2618 -**3)Set communication port parameters**
2619 -
2620 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2621 -
2622 -HMI IP address:192.168.39.201
2623 -
2624 -default gateway:192.168.39.1
2625 -
2626 -subnet mask:255.255.255.0
2627 -
2628 -[[image:image-20220811170753-2.png]]
2629 -
2630 -Next, click Communication Settings to configure the IP of the HMI communication object.
2631 -
2632 -[[image:image-20220811163047-1.png]]
2633 -
2634 -**hardware connection**
2635 -
2636 -**1)Hardware wiring diagram**
2637 -
2638 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2639 -
2640 -[[image:image-20220811170248-1.png]]
2641 -
2642 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
S7-XXXCommunication Settings.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -32.6 KB
Content
S7-XXXCommunication SettingsPI.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
S7-XXXCommunication SettingsPIStudio.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
SiemensLOGODeviceIP.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
image-20220811115454-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -204.7 KB
Content
image-20220811140308-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -122.3 KB
Content
image-20220811140530-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -126.0 KB
Content
image-20220811163047-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -165.7 KB
Content
image-20220811163943-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -153.6 KB
Content
image-20220811170248-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -91.7 KB
Content
image-20220811170753-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -154.4 KB
Content