Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Ben - Content
-
... ... @@ -1896,7 +1896,7 @@ 1896 1896 1897 1897 == **LOGO Ethernet** == 1898 1898 1899 -Supported Series: Siemens Logo 0BA0 series1899 +Supported Series: Siemens Logo 1900 1900 1901 1901 **HMI Settings** 1902 1902 ... ... @@ -1959,8 +1959,9 @@ 1959 1959 Set PLC IP in [Device IP] settings; 1960 1960 1961 1961 (% style="text-align:center" %) 1962 -[[image: SiemensLOGODeviceIP.png]]1962 +[[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]] 1963 1963 1964 + 1964 1964 Enable HMI Ethernet in [Project Settings]; 1965 1965 1966 1966 (% style="text-align:center" %) ... ... @@ -1992,28 +1992,17 @@ 1992 1992 1993 1993 == **S7-XXX Ethernet** == 1994 1994 1995 -Supported Series: Siemens S7- 400, S7-1200 and S7-15001996 +Supported Series: Siemens S7-1200 and S7-1500 1996 1996 1997 1997 **HMI Setting** 1998 1998 1999 -(% class="table-bordered" style="width:823px" %) 2000 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 2001 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 2002 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 2003 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 2004 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 2005 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 2000 +(% class="table-bordered" %) 2001 +|**Items**|**Settings**|**Note** 2002 +|Protocol|Siemens S7-XXX| 2003 +|Connection|Ethernet| 2004 +|Port No.|102| 2005 +|PLC station No.|1 (for S7-1500)/ 2 (for S7-1200)| 2006 2006 2007 -Slot from TIA Portal is equal to Device No. of PIStudio 2008 - 2009 -Rack from TIA Portal is equal to HMI No. of PIStudio 2010 - 2011 -(% style="text-align:center" %) 2012 -[[image:S7-XXXCommunication Settings.png]] 2013 - 2014 -(% style="text-align:center" %) 2015 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 2016 - 2017 2017 **Address List** 2018 2018 2019 2019 (% class="table-bordered" %) ... ... @@ -2635,7 +2635,7 @@ 2635 2635 2636 2636 **1)Hardware wiring diagram** 2637 2637 2638 -This example introduces WeconHMI with LX5V -NPLC to establish communication through ethernet. The connection diagram is as follows:2628 +This example introduces WeconHMI with LX5V PLC to establish communication through ethernet. The connection diagram is as follows: 2639 2639 2640 2640 [[image:image-20220811170248-1.png]] 2641 2641
- S7-XXXCommunication Settings.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content
- S7-XXXCommunication SettingsPI.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- S7-XXXCommunication SettingsPIStudio.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- SiemensLOGODeviceIP.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Hunter - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content