Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -2487,12 +2487,10 @@ 2487 2487 2488 2488 **✎Note:** COM3 only available in PI8000/PI9000 series. 2489 2489 2490 +== HMI and Wecon LX5V serial communication == 2490 2490 2491 -== **1. HMI and Wecon LX5V serial communication** == 2492 - 2493 2493 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2494 2494 2495 - 2496 2496 **Software configuration of PLC** 2497 2497 2498 2498 **1)PLC programming software** ... ... @@ -2567,7 +2567,7 @@ 2567 2567 2568 2568 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2569 2569 2570 -== **2.HMI and Wecon LX5V-N Ethernet communication**==2568 +== HMI and Wecon LX5V-N Ethernet communication == 2571 2571 2572 2572 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2573 2573 ... ... @@ -2640,3 +2640,47 @@ 2640 2640 [[image:image-20220811170248-1.png]] 2641 2641 2642 2642 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2641 + 2642 += **Schneider MODBUS RTU** = 2643 + 2644 +**HMI Setting** 2645 + 2646 +|=(% scope="row" %)**Parameters**|=**Recommended**|=**Options**|=**Notes** 2647 +|=**Protocol**|(% colspan="2" %)Schneider MODBUS RTU| 2648 +|=Connection|RS485|RS232/RS485| 2649 +|=**Baud rate**|19200|9600~~115200| 2650 +|=**Data bit**|8|7,8| 2651 +|=**Parity**|Even|Even, Odd, None| 2652 +|=**Stop bits**|1|1,2| 2653 +|=**PLC station No.**|1|0-255| 2654 + 2655 +|=(% scope="row" style="width: 266px;" %)**Online simulator**|(% style="width:319px" %)YES|(% style="width:336px" %)**Broadcast command**|(% style="width:155px" %)YES 2656 +|=(% style="width: 266px;" %)**Extend address mode**|(% style="width:319px" %)YES|(% style="width:336px" %) |(% style="width:155px" %) 2657 + 2658 +**PLC Setting** 2659 + 2660 +|=(% scope="row" %)**Communication mode**|Modbus RTU protocol 2661 + 2662 +**Device Address** 2663 + 2664 +|=(% scope="row" %)**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 2665 +|=B|%IX|DDDDDo|0 ~~ 655357|Input bit (read only) 2666 +|=B|%QX|DDDDDo|0 ~~ 655357|Write multiple coils 2667 +|=B|%MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 2668 +|=B|%M|DDDDD|0 ~~ 65535|Output bit 2669 +|=B|%MW_Bit|DDDDDdd|0 ~~ 6553515|Output register bit (decimal) 2670 +|=B|1x|DDDDD|0 ~~ 65535|Input bit (read only) 2671 +|=B|0x_multi_coils|DDDDD|0 ~~ 65535|Write multiple coils 2672 +|=B|3x_Bit|DDDDDdd|0 ~~ 6553515|Input register bit (read only) 2673 +|=W|%MW|DDDDDD|0 ~~ 999999|Output register 2674 +|=DW|%MD|DDDDDD|0 ~~ 999999|Output register 2675 +|=W|3x|DDDDD|0 ~~ 65535|Input Register (read only) 2676 +|=DW|5x|DDDDD|0 ~~ 65535|4x double word swap 2677 +|=DW|6x|DDDDD|0 ~~ 65535|4x single word write 2678 + 2679 +**Wiring Diagram** 2680 + 2681 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 2682 + 2683 +(% style="text-align:center" %) 2684 +[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
- image-20220817154212-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.8 KB - Content