Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Ben - Content
-
... ... @@ -2303,9 +2303,6 @@ 2303 2303 * **RS485** 2304 2304 2305 2305 (% style="text-align:center" %) 2306 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2307 - 2308 -(% style="text-align:center" %) 2309 2309 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2310 2310 2311 2311 * **RS422** ... ... @@ -2320,6 +2320,159 @@ 2320 2320 2321 2321 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 2322 2322 2320 + 2321 +== **HMI and Wecon LX5V serial communication** == 2322 + 2323 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2324 + 2325 +**Software configuration of PLC** 2326 + 2327 +**1)PLC programming software** 2328 + 2329 +[[image:image-20220810164710-1.png]] 2330 + 2331 +**2)New PLC project** 2332 + 2333 +Click New Project and select the PLC model. 2334 + 2335 +[[image:image-20220810172412-1.png]] 2336 + 2337 + 2338 +**3)Set Serial port parameters** 2339 + 2340 +Follow the steps below to configure Serial port parameters 2341 + 2342 +Baud rate:115200 2343 + 2344 +Data bit:8 2345 + 2346 +Stop bit:1 2347 + 2348 +Parity:No verification 2349 + 2350 +[[image:image-20220810165759-3.png]] 2351 + 2352 + 2353 +**4)Registers list** 2354 + 2355 +[[image:image-20220811102219-3.png]] 2356 + 2357 + 2358 +**HMI software configuration** 2359 + 2360 +**1)HMI programming software** 2361 + 2362 + [[image:image-20220810171237-4.png]] 2363 + 2364 +**2)New HMI project** 2365 + 2366 +Click New Project and select the HMI model. 2367 + 2368 +[[image:image-20220810172010-5.png]] 2369 + 2370 +**3)Set communication port parameters** 2371 + 2372 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2373 + 2374 +Baud rate:115200 2375 + 2376 +Data bit:8 2377 + 2378 +Stop bit:1 2379 + 2380 +Parity:No verification 2381 + 2382 + 2383 +[[image:image-20220811104012-1.png]] 2384 + 2385 + 2386 +**hardware connection** 2387 + 2388 +**1)Hardware wiring diagram** 2389 + 2390 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2391 + 2392 +[[image:image-20220811103005-4.png]] 2393 + 2394 + 2395 +[[image:image-20220811103227-7.png]] 2396 + 2397 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2398 + 2399 +== **HMI and Wecon LX5V-N Ethernet communication** == 2400 + 2401 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2402 + 2403 + 2404 +**Software configuration of PLC** 2405 + 2406 +**1)PLC programming software** 2407 + 2408 +[[image:image-20220810164710-1.png]] 2409 + 2410 +**2)New PLC project** 2411 + 2412 +Click New Project and select the PLC model. 2413 + 2414 +[[image:image-20220811115454-1.png]] 2415 + 2416 + 2417 +**3)Set Ethernet port parameters** 2418 + 2419 +Follow the steps below to configure Ethernet parameters 2420 + 2421 +PLC IP address:192.168.39.200 2422 + 2423 +default gateway:192.168.39.1 2424 + 2425 +subnet mask:255.255.255.0 2426 + 2427 +[[image:image-20220811140530-2.png]] 2428 + 2429 + 2430 +**4)Registers list** 2431 + 2432 +[[image:image-20220811102219-3.png]] 2433 + 2434 + 2435 +**HMI software configuration** 2436 + 2437 +**1)HMI programming software** 2438 + 2439 + [[image:image-20220810171237-4.png]] 2440 + 2441 +**2)New HMI project** 2442 + 2443 +Click New Project and select the HMI model. 2444 + 2445 +[[image:image-20220810172010-5.png]] 2446 + 2447 +**3)Set communication port parameters** 2448 + 2449 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2450 + 2451 +HMI IP address:192.168.39.201 2452 + 2453 +default gateway:192.168.39.1 2454 + 2455 +subnet mask:255.255.255.0 2456 + 2457 +[[image:image-20220811170753-2.png]] 2458 + 2459 +Next, click Communication Settings to configure the IP of the HMI communication object. 2460 + 2461 +[[image:image-20220811163047-1.png]] 2462 + 2463 +**hardware connection** 2464 + 2465 +**1)Hardware wiring diagram** 2466 + 2467 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2468 + 2469 +[[image:image-20220811170248-1.png]] 2470 + 2471 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2472 + 2323 2323 = **Printer** = 2324 2324 2325 2325 == **TSPL label printer** == ... ... @@ -2488,155 +2488,35 @@ 2488 2488 **✎Note:** COM3 only available in PI8000/PI9000 series. 2489 2489 2490 2490 2491 -= =**1. HMI and WeconLX5V serialcommunication** ==2641 += **Schneider MODBUS RTU** = 2492 2492 2493 - This example introduces the establishment of serial port communication between WeconHMIand LX5V. It is introducedthroughthree parts: PLC software configuration, HMI software configuration, and hardware wiring.2643 +**HMI Setting** 2494 2494 2645 +|=**Parameters**|=**Recommended**|=**Notes** 2646 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 2647 +|Connection|RS485| 2648 +|**Baud rate**|19200| 2649 +|**Data bit**|8| 2650 +|**Parity**|Even| 2651 +|**Stop bit**|1| 2652 +|**PLC station No.**|1| 2495 2495 2496 -**S oftwareconfigurationof PLC**2654 +**PLC Setting** 2497 2497 2498 - **1)PLCprogrammingsoftware**2656 +|=(% scope="row" %)**Communication mode**|Modbus RTU protocol 2499 2499 2500 - [[image:image-20220810164710-1.png]]2658 +**Device Address** 2501 2501 2502 -**2)New PLC project** 2660 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 2661 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 2662 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 2663 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 2664 +|W|MW|DDDDDD|0 ~~ 999999|Output register 2665 +|DW|MD|DDDDDD|0 ~~ 999999|Output register 2503 2503 2504 - Click New Project andselect the PLCmodel.2667 +**Wiring Diagram** 2505 2505 2506 - [[image:image-20220810172412-1.png]]2669 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 2507 2507 2508 - 2509 -**3)Set Serial port parameters** 2510 - 2511 -Follow the steps below to configure Serial port parameters 2512 - 2513 -Baud rate:115200 2514 - 2515 -Data bit:8 2516 - 2517 -Stop bit:1 2518 - 2519 -Parity:No verification 2520 - 2521 -[[image:image-20220810165759-3.png]] 2522 - 2523 - 2524 -**4)Registers list** 2525 - 2526 -[[image:image-20220811102219-3.png]] 2527 - 2528 - 2529 -**HMI software configuration** 2530 - 2531 -**1)HMI programming software** 2532 - 2533 - [[image:image-20220810171237-4.png]] 2534 - 2535 -**2)New HMI project** 2536 - 2537 -Click New Project and select the HMI model. 2538 - 2539 -[[image:image-20220810172010-5.png]] 2540 - 2541 -**3)Set communication port parameters** 2542 - 2543 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2544 - 2545 -Baud rate:115200 2546 - 2547 -Data bit:8 2548 - 2549 -Stop bit:1 2550 - 2551 -Parity:No verification 2552 - 2553 - 2554 -[[image:image-20220811104012-1.png]] 2555 - 2556 - 2557 -**hardware connection** 2558 - 2559 -**1)Hardware wiring diagram** 2560 - 2561 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2562 - 2563 -[[image:image-20220811103005-4.png]] 2564 - 2565 - 2566 -[[image:image-20220811103227-7.png]] 2567 - 2568 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2569 - 2570 -== **2. HMI and Wecon LX5V-N Ethernet communication** == 2571 - 2572 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2573 - 2574 - 2575 -**Software configuration of PLC** 2576 - 2577 -**1)PLC programming software** 2578 - 2579 -[[image:image-20220810164710-1.png]] 2580 - 2581 -**2)New PLC project** 2582 - 2583 -Click New Project and select the PLC model. 2584 - 2585 -[[image:image-20220811115454-1.png]] 2586 - 2587 - 2588 -**3)Set Ethernet port parameters** 2589 - 2590 -Follow the steps below to configure Ethernet parameters 2591 - 2592 -PLC IP address:192.168.39.200 2593 - 2594 -default gateway:192.168.39.1 2595 - 2596 -subnet mask:255.255.255.0 2597 - 2598 -[[image:image-20220811140530-2.png]] 2599 - 2600 - 2601 -**4)Registers list** 2602 - 2603 -[[image:image-20220811102219-3.png]] 2604 - 2605 - 2606 -**HMI software configuration** 2607 - 2608 -**1)HMI programming software** 2609 - 2610 - [[image:image-20220810171237-4.png]] 2611 - 2612 -**2)New HMI project** 2613 - 2614 -Click New Project and select the HMI model. 2615 - 2616 -[[image:image-20220810172010-5.png]] 2617 - 2618 -**3)Set communication port parameters** 2619 - 2620 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2621 - 2622 -HMI IP address:192.168.39.201 2623 - 2624 -default gateway:192.168.39.1 2625 - 2626 -subnet mask:255.255.255.0 2627 - 2628 -[[image:image-20220811170753-2.png]] 2629 - 2630 -Next, click Communication Settings to configure the IP of the HMI communication object. 2631 - 2632 -[[image:image-20220811163047-1.png]] 2633 - 2634 -**hardware connection** 2635 - 2636 -**1)Hardware wiring diagram** 2637 - 2638 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2639 - 2640 -[[image:image-20220811170248-1.png]] 2641 - 2642 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2671 +(% style="text-align:center" %) 2672 +[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
- image-20220817154212-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.8 KB - Content