Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 28.1
edited by Stone Wu
on 2022/08/17 15:51
Change comment: There is no comment for this version
To version 26.1
edited by Stone Wu
on 2022/08/17 15:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2640,45 +2640,3 @@
2640 2640  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2641 2641  
2642 2642  = **Schneider MODBUS RTU** =
2643 -
2644 -**HMI Setting**
2645 -
2646 -|=(% scope="row" %)**Parameters**|=**Recommended**|=**Options**|=**Notes**
2647 -|=**Protocol**|(% colspan="2" %)Schneider MODBUS RTU|
2648 -|=Connection|RS485|RS232/RS485|
2649 -|=**Baud rate**|19200|9600~~115200|
2650 -|=**Data bit**|8|7,8|
2651 -|=**Parity**|Even|Even, Odd, None|
2652 -|=**Stop bits**|1|1,2|
2653 -|=**PLC station No.**|1|0-255|
2654 -
2655 -|=(% scope="row" style="width: 266px;" %)**Online simulator**|(% style="width:319px" %)YES|(% style="width:336px" %)**Broadcast command**|(% style="width:155px" %)YES
2656 -|=(% style="width: 266px;" %)**Extend address mode**|(% style="width:319px" %)YES|(% style="width:336px" %) |(% style="width:155px" %)
2657 -
2658 -**PLC Setting**
2659 -
2660 -|=(% scope="row" %)**Communication mode**|Modbus RTU protocol
2661 -
2662 -**Device Address**
2663 -
2664 -|=(% scope="row" %)**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2665 -|=B|%IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2666 -|=B|%QX|DDDDDo|0 ~~ 655357|Write multiple coils
2667 -|=B|%MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2668 -|=B|%M|DDDDD|0 ~~ 65535|Output bit
2669 -|=B|%MW_Bit|DDDDDdd|0 ~~ 6553515|Output register bit (decimal)
2670 -|=B|1x|DDDDD|0 ~~ 65535|Input bit (read only)
2671 -|=B|0x_multi_coils|DDDDD|0 ~~ 65535|Write multiple coils
2672 -|=B|3x_Bit|DDDDDdd|0 ~~ 6553515|Input register bit (read only)
2673 -|=W|%MW|DDDDDD|0 ~~ 999999|Output register
2674 -|=DW|%MD|DDDDDD|0 ~~ 999999|Output register
2675 -|=W|3x|DDDDD|0 ~~ 65535|Input Register (read only)
2676 -|=DW|5x|DDDDD|0 ~~ 65535|4x double word swap
2677 -|=DW|6x|DDDDD|0 ~~ 65535|4x single word write
2678 -
2679 -**Wiring Diagram**
2680 -
2681 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
2682 -
2683 -(% style="text-align:center" %)
2684 -[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
image-20220817154212-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.8 KB
Content