Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 35.1
edited by Ben
on 2022/08/19 11:22
Change comment: There is no comment for this version
To version 24.1
edited by Hunter
on 2022/08/15 10:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Hunter
Content
... ... @@ -1896,7 +1896,7 @@
1896 1896  
1897 1897  == **LOGO Ethernet** ==
1898 1898  
1899 -Supported Series: Siemens Logo 0BA0 series
1899 +Supported Series: Siemens Logo
1900 1900  
1901 1901  **HMI Settings**
1902 1902  
... ... @@ -1959,8 +1959,9 @@
1959 1959  Set PLC IP in [Device IP] settings;
1960 1960  
1961 1961  (% style="text-align:center" %)
1962 -[[image:SiemensLOGODeviceIP.png]]
1962 +[[image:12.PLC Protocol_html_573fc64ad393cd4f.png||data-xwiki-image-style-alignment="center" height="655" width="379" class="img-thumbnail"]]
1963 1963  
1964 +
1964 1964  Enable HMI Ethernet in [Project Settings];
1965 1965  
1966 1966  (% style="text-align:center" %)
... ... @@ -2320,162 +2320,6 @@
2320 2320  
2321 2321  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2322 2322  
2323 -
2324 -== HMI and Wecon LX5V serial communication ==
2325 -
2326 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2327 -
2328 -**Software configuration of PLC**
2329 -
2330 -**1)PLC programming software**
2331 -
2332 -[[image:image-20220810164710-1.png]]
2333 -
2334 -**2)New PLC project**
2335 -
2336 -Click New Project and select the PLC model.
2337 -
2338 -[[image:image-20220810172412-1.png]]
2339 -
2340 -
2341 -**3)Set Serial port parameters**
2342 -
2343 -Follow the steps below to configure Serial port parameters
2344 -
2345 -Baud rate:115200
2346 -
2347 -Data bit:8
2348 -
2349 -Stop bit:1
2350 -
2351 -Parity:No verification
2352 -
2353 -[[image:image-20220810165759-3.png]]
2354 -
2355 -
2356 -**4)Registers list**
2357 -
2358 -[[image:image-20220811102219-3.png]]
2359 -
2360 -
2361 -**HMI software configuration**
2362 -
2363 -**1)HMI programming software**
2364 -
2365 - [[image:image-20220810171237-4.png]]
2366 -
2367 -**2)New HMI project**
2368 -
2369 -Click New Project and select the HMI model.
2370 -
2371 -[[image:image-20220810172010-5.png]]
2372 -
2373 -**3)Set communication port parameters**
2374 -
2375 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2376 -
2377 -Baud rate:115200
2378 -
2379 -Data bit:8
2380 -
2381 -Stop bit:1
2382 -
2383 -Parity:No verification
2384 -
2385 -
2386 -[[image:image-20220811104012-1.png]]
2387 -
2388 -
2389 -**hardware connection**
2390 -
2391 -**1)Hardware wiring diagram**
2392 -
2393 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2394 -
2395 -[[image:image-20220811103005-4.png]]
2396 -
2397 -
2398 -[[image:image-20220811103227-7.png]]
2399 -
2400 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2401 -
2402 -(% class="wikigeneratedid" %)
2403 -== ==
2404 -
2405 -== HMI and Wecon LX5V-N Ethernet communication ==
2406 -
2407 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2408 -
2409 -
2410 -**Software configuration of PLC**
2411 -
2412 -**1)PLC programming software**
2413 -
2414 -[[image:image-20220810164710-1.png]]
2415 -
2416 -**2)New PLC project**
2417 -
2418 -Click New Project and select the PLC model.
2419 -
2420 -[[image:image-20220811115454-1.png]]
2421 -
2422 -
2423 -**3)Set Ethernet port parameters**
2424 -
2425 -Follow the steps below to configure Ethernet parameters
2426 -
2427 -PLC IP address:192.168.39.200
2428 -
2429 -default gateway:192.168.39.1
2430 -
2431 -subnet mask:255.255.255.0
2432 -
2433 -[[image:image-20220811140530-2.png]]
2434 -
2435 -
2436 -**4)Registers list**
2437 -
2438 -[[image:image-20220811102219-3.png]]
2439 -
2440 -
2441 -**HMI software configuration**
2442 -
2443 -**1)HMI programming software**
2444 -
2445 - [[image:image-20220810171237-4.png]]
2446 -
2447 -**2)New HMI project**
2448 -
2449 -Click New Project and select the HMI model.
2450 -
2451 -[[image:image-20220810172010-5.png]]
2452 -
2453 -**3)Set communication port parameters**
2454 -
2455 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2456 -
2457 -HMI IP address:192.168.39.201
2458 -
2459 -default gateway:192.168.39.1
2460 -
2461 -subnet mask:255.255.255.0
2462 -
2463 -[[image:image-20220811170753-2.png]]
2464 -
2465 -Next, click Communication Settings to configure the IP of the HMI communication object.
2466 -
2467 -[[image:image-20220811163047-1.png]]
2468 -
2469 -**hardware connection**
2470 -
2471 -**1)Hardware wiring diagram**
2472 -
2473 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2474 -
2475 -[[image:image-20220811170248-1.png]]
2476 -
2477 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2478 -
2479 2479  = **Printer** =
2480 2480  
2481 2481  == **TSPL label printer** ==
... ... @@ -2644,35 +2644,155 @@
2644 2644  **✎Note:** COM3 only available in PI8000/PI9000 series.
2645 2645  
2646 2646  
2647 -= **Schneider MODBUS RTU** =
2492 +== **1. HMI and Wecon LX5V serial communication** ==
2648 2648  
2649 -**HMI Setting**
2494 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2650 2650  
2651 -|=**Parameters**|=**Recommended**|=**Notes**
2652 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
2653 -|Connection|RS485|
2654 -|**Baud rate**|19200|
2655 -|**Data bit**|8|
2656 -|**Parity**|Even|
2657 -|**Stop bit**|1|
2658 -|**PLC station No.**|1|
2659 2659  
2660 -**PLC Setting**
2497 +**Software configuration of PLC**
2661 2661  
2662 -|=(% scope="row" %)**Communication mode**|Modbus RTU protocol
2499 +**1)PLC programming software**
2663 2663  
2664 -**Device Address**
2501 +[[image:image-20220810164710-1.png]]
2665 2665  
2666 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2667 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2668 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
2669 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2670 -|W|MW|DDDDDD|0 ~~ 999999|Output register
2671 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
2503 +**2)New PLC project**
2672 2672  
2673 -**Wiring Diagram**
2505 +Click New Project and select the PLC model.
2674 2674  
2675 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
2507 +[[image:image-20220810172412-1.png]]
2676 2676  
2677 -(% style="text-align:center" %)
2678 -[[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2509 +
2510 +**3)Set Serial port parameters**
2511 +
2512 +Follow the steps below to configure Serial port parameters
2513 +
2514 +Baud rate:115200
2515 +
2516 +Data bit:8
2517 +
2518 +Stop bit:1
2519 +
2520 +Parity:No verification
2521 +
2522 +[[image:image-20220810165759-3.png]]
2523 +
2524 +
2525 +**4)Registers list**
2526 +
2527 +[[image:image-20220811102219-3.png]]
2528 +
2529 +
2530 +**HMI software configuration**
2531 +
2532 +**1)HMI programming software**
2533 +
2534 + [[image:image-20220810171237-4.png]]
2535 +
2536 +**2)New HMI project**
2537 +
2538 +Click New Project and select the HMI model.
2539 +
2540 +[[image:image-20220810172010-5.png]]
2541 +
2542 +**3)Set communication port parameters**
2543 +
2544 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2545 +
2546 +Baud rate:115200
2547 +
2548 +Data bit:8
2549 +
2550 +Stop bit:1
2551 +
2552 +Parity:No verification
2553 +
2554 +
2555 +[[image:image-20220811104012-1.png]]
2556 +
2557 +
2558 +**hardware connection**
2559 +
2560 +**1)Hardware wiring diagram**
2561 +
2562 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2563 +
2564 +[[image:image-20220811103005-4.png]]
2565 +
2566 +
2567 +[[image:image-20220811103227-7.png]]
2568 +
2569 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2570 +
2571 +== **2. HMI and Wecon LX5V-N Ethernet communication** ==
2572 +
2573 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2574 +
2575 +
2576 +**Software configuration of PLC**
2577 +
2578 +**1)PLC programming software**
2579 +
2580 +[[image:image-20220810164710-1.png]]
2581 +
2582 +**2)New PLC project**
2583 +
2584 +Click New Project and select the PLC model.
2585 +
2586 +[[image:image-20220811115454-1.png]]
2587 +
2588 +
2589 +**3)Set Ethernet port parameters**
2590 +
2591 +Follow the steps below to configure Ethernet parameters
2592 +
2593 +PLC IP address:192.168.39.200
2594 +
2595 +default gateway:192.168.39.1
2596 +
2597 +subnet mask:255.255.255.0
2598 +
2599 +[[image:image-20220811140530-2.png]]
2600 +
2601 +
2602 +**4)Registers list**
2603 +
2604 +[[image:image-20220811102219-3.png]]
2605 +
2606 +
2607 +**HMI software configuration**
2608 +
2609 +**1)HMI programming software**
2610 +
2611 + [[image:image-20220810171237-4.png]]
2612 +
2613 +**2)New HMI project**
2614 +
2615 +Click New Project and select the HMI model.
2616 +
2617 +[[image:image-20220810172010-5.png]]
2618 +
2619 +**3)Set communication port parameters**
2620 +
2621 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2622 +
2623 +HMI IP address:192.168.39.201
2624 +
2625 +default gateway:192.168.39.1
2626 +
2627 +subnet mask:255.255.255.0
2628 +
2629 +[[image:image-20220811170753-2.png]]
2630 +
2631 +Next, click Communication Settings to configure the IP of the HMI communication object.
2632 +
2633 +[[image:image-20220811163047-1.png]]
2634 +
2635 +**hardware connection**
2636 +
2637 +**1)Hardware wiring diagram**
2638 +
2639 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2640 +
2641 +[[image:image-20220811170248-1.png]]
2642 +
2643 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
SiemensLOGODeviceIP.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
image-20220817154212-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -51.8 KB
Content