Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 36.1
edited by Ben
on 2022/08/19 11:23
Change comment: There is no comment for this version
To version 27.1
edited by Stone Wu
on 2022/08/17 15:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Stone
Content
... ... @@ -2320,159 +2320,6 @@
2320 2320  
2321 2321  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2322 2322  
2323 -
2324 -== HMI and Wecon LX5V serial communication ==
2325 -
2326 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2327 -
2328 -**Software configuration of PLC**
2329 -
2330 -**1)PLC programming software**
2331 -
2332 -[[image:image-20220810164710-1.png]]
2333 -
2334 -**2)New PLC project**
2335 -
2336 -Click New Project and select the PLC model.
2337 -
2338 -[[image:image-20220810172412-1.png]]
2339 -
2340 -
2341 -**3)Set Serial port parameters**
2342 -
2343 -Follow the steps below to configure Serial port parameters
2344 -
2345 -Baud rate:115200
2346 -
2347 -Data bit:8
2348 -
2349 -Stop bit:1
2350 -
2351 -Parity:No verification
2352 -
2353 -[[image:image-20220810165759-3.png]]
2354 -
2355 -
2356 -**4)Registers list**
2357 -
2358 -[[image:image-20220811102219-3.png]]
2359 -
2360 -
2361 -**HMI software configuration**
2362 -
2363 -**1)HMI programming software**
2364 -
2365 - [[image:image-20220810171237-4.png]]
2366 -
2367 -**2)New HMI project**
2368 -
2369 -Click New Project and select the HMI model.
2370 -
2371 -[[image:image-20220810172010-5.png]]
2372 -
2373 -**3)Set communication port parameters**
2374 -
2375 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2376 -
2377 -Baud rate:115200
2378 -
2379 -Data bit:8
2380 -
2381 -Stop bit:1
2382 -
2383 -Parity:No verification
2384 -
2385 -
2386 -[[image:image-20220811104012-1.png]]
2387 -
2388 -
2389 -**hardware connection**
2390 -
2391 -**1)Hardware wiring diagram**
2392 -
2393 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2394 -
2395 -[[image:image-20220811103005-4.png]]
2396 -
2397 -
2398 -[[image:image-20220811103227-7.png]]
2399 -
2400 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2401 -
2402 -== HMI and Wecon LX5V-N Ethernet communication ==
2403 -
2404 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2405 -
2406 -
2407 -**Software configuration of PLC**
2408 -
2409 -**1)PLC programming software**
2410 -
2411 -[[image:image-20220810164710-1.png]]
2412 -
2413 -**2)New PLC project**
2414 -
2415 -Click New Project and select the PLC model.
2416 -
2417 -[[image:image-20220811115454-1.png]]
2418 -
2419 -
2420 -**3)Set Ethernet port parameters**
2421 -
2422 -Follow the steps below to configure Ethernet parameters
2423 -
2424 -PLC IP address:192.168.39.200
2425 -
2426 -default gateway:192.168.39.1
2427 -
2428 -subnet mask:255.255.255.0
2429 -
2430 -[[image:image-20220811140530-2.png]]
2431 -
2432 -
2433 -**4)Registers list**
2434 -
2435 -[[image:image-20220811102219-3.png]]
2436 -
2437 -
2438 -**HMI software configuration**
2439 -
2440 -**1)HMI programming software**
2441 -
2442 - [[image:image-20220810171237-4.png]]
2443 -
2444 -**2)New HMI project**
2445 -
2446 -Click New Project and select the HMI model.
2447 -
2448 -[[image:image-20220810172010-5.png]]
2449 -
2450 -**3)Set communication port parameters**
2451 -
2452 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2453 -
2454 -HMI IP address:192.168.39.201
2455 -
2456 -default gateway:192.168.39.1
2457 -
2458 -subnet mask:255.255.255.0
2459 -
2460 -[[image:image-20220811170753-2.png]]
2461 -
2462 -Next, click Communication Settings to configure the IP of the HMI communication object.
2463 -
2464 -[[image:image-20220811163047-1.png]]
2465 -
2466 -**hardware connection**
2467 -
2468 -**1)Hardware wiring diagram**
2469 -
2470 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2471 -
2472 -[[image:image-20220811170248-1.png]]
2473 -
2474 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2475 -
2476 2476  = **Printer** =
2477 2477  
2478 2478  == **TSPL label printer** ==
... ... @@ -2640,20 +2640,174 @@
2640 2640  
2641 2641  **✎Note:** COM3 only available in PI8000/PI9000 series.
2642 2642  
2490 +== HMI and Wecon LX5V serial communication ==
2643 2643  
2492 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2493 +
2494 +**Software configuration of PLC**
2495 +
2496 +**1)PLC programming software**
2497 +
2498 +[[image:image-20220810164710-1.png]]
2499 +
2500 +**2)New PLC project**
2501 +
2502 +Click New Project and select the PLC model.
2503 +
2504 +[[image:image-20220810172412-1.png]]
2505 +
2506 +
2507 +**3)Set Serial port parameters**
2508 +
2509 +Follow the steps below to configure Serial port parameters
2510 +
2511 +Baud rate:115200
2512 +
2513 +Data bit:8
2514 +
2515 +Stop bit:1
2516 +
2517 +Parity:No verification
2518 +
2519 +[[image:image-20220810165759-3.png]]
2520 +
2521 +
2522 +**4)Registers list**
2523 +
2524 +[[image:image-20220811102219-3.png]]
2525 +
2526 +
2527 +**HMI software configuration**
2528 +
2529 +**1)HMI programming software**
2530 +
2531 + [[image:image-20220810171237-4.png]]
2532 +
2533 +**2)New HMI project**
2534 +
2535 +Click New Project and select the HMI model.
2536 +
2537 +[[image:image-20220810172010-5.png]]
2538 +
2539 +**3)Set communication port parameters**
2540 +
2541 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2542 +
2543 +Baud rate:115200
2544 +
2545 +Data bit:8
2546 +
2547 +Stop bit:1
2548 +
2549 +Parity:No verification
2550 +
2551 +
2552 +[[image:image-20220811104012-1.png]]
2553 +
2554 +
2555 +**hardware connection**
2556 +
2557 +**1)Hardware wiring diagram**
2558 +
2559 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2560 +
2561 +[[image:image-20220811103005-4.png]]
2562 +
2563 +
2564 +[[image:image-20220811103227-7.png]]
2565 +
2566 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2567 +
2568 +== HMI and Wecon LX5V-N Ethernet communication ==
2569 +
2570 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2571 +
2572 +
2573 +**Software configuration of PLC**
2574 +
2575 +**1)PLC programming software**
2576 +
2577 +[[image:image-20220810164710-1.png]]
2578 +
2579 +**2)New PLC project**
2580 +
2581 +Click New Project and select the PLC model.
2582 +
2583 +[[image:image-20220811115454-1.png]]
2584 +
2585 +
2586 +**3)Set Ethernet port parameters**
2587 +
2588 +Follow the steps below to configure Ethernet parameters
2589 +
2590 +PLC IP address:192.168.39.200
2591 +
2592 +default gateway:192.168.39.1
2593 +
2594 +subnet mask:255.255.255.0
2595 +
2596 +[[image:image-20220811140530-2.png]]
2597 +
2598 +
2599 +**4)Registers list**
2600 +
2601 +[[image:image-20220811102219-3.png]]
2602 +
2603 +
2604 +**HMI software configuration**
2605 +
2606 +**1)HMI programming software**
2607 +
2608 + [[image:image-20220810171237-4.png]]
2609 +
2610 +**2)New HMI project**
2611 +
2612 +Click New Project and select the HMI model.
2613 +
2614 +[[image:image-20220810172010-5.png]]
2615 +
2616 +**3)Set communication port parameters**
2617 +
2618 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2619 +
2620 +HMI IP address:192.168.39.201
2621 +
2622 +default gateway:192.168.39.1
2623 +
2624 +subnet mask:255.255.255.0
2625 +
2626 +[[image:image-20220811170753-2.png]]
2627 +
2628 +Next, click Communication Settings to configure the IP of the HMI communication object.
2629 +
2630 +[[image:image-20220811163047-1.png]]
2631 +
2632 +**hardware connection**
2633 +
2634 +**1)Hardware wiring diagram**
2635 +
2636 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2637 +
2638 +[[image:image-20220811170248-1.png]]
2639 +
2640 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2641 +
2644 2644  = **Schneider MODBUS RTU** =
2645 2645  
2646 2646  **HMI Setting**
2647 2647  
2648 -|=**Parameters**|=**Recommended**|=**Notes**
2649 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
2650 -|Connection|RS485|
2651 -|**Baud rate**|19200|
2652 -|**Data bit**|8|
2653 -|**Parity**|Even|
2654 -|**Stop bit**|1|
2655 -|**PLC station No.**|1|
2646 +|=(% scope="row" %)**Parameters**|=**Recommended**|=**Options**|=**Notes**
2647 +|=**PLC type**|(% colspan="2" %)Schneider MODBUS RTU|
2648 +|=**PLC I/F**|RS485|RS232/RS485|
2649 +|=**Baud rate**|19200|9600~~115200|
2650 +|=**Data bits**|8|7,8|
2651 +|=**Parity**|Even|Even, Odd, None|
2652 +|=**Stop bits**|1|1,2|
2653 +|=**PLC sta. no.**|1|0-255|
2656 2656  
2655 +|=(% scope="row" style="width: 266px;" %)**Online simulator**|(% style="width:319px" %)YES|(% style="width:336px" %)**Broadcast command**|(% style="width:155px" %)YES
2656 +|=(% style="width: 266px;" %)**Extend address mode**|(% style="width:319px" %)YES|(% style="width:336px" %) |(% style="width:155px" %)
2657 +
2657 2657  **PLC Setting**
2658 2658  
2659 2659  |=(% scope="row" %)**Communication mode**|Modbus RTU protocol
... ... @@ -2660,12 +2660,20 @@
2660 2660  
2661 2661  **Device Address**
2662 2662  
2663 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2664 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2665 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
2666 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2667 -|W|MW|DDDDDD|0 ~~ 999999|Output register
2668 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
2664 +|=(% scope="row" %)**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2665 +|=B|%IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2666 +|=B|%QX|DDDDDo|0 ~~ 655357|Write multiple coils
2667 +|=B|%MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2668 +|=B|%M|DDDDD|0 ~~ 65535|Output bit
2669 +|=B|%MW_Bit|DDDDDdd|0 ~~ 6553515|Output register bit (decimal)
2670 +|=B|1x|DDDDD|0 ~~ 65535|Input bit (read only)
2671 +|=B|0x_multi_coils|DDDDD|0 ~~ 65535|Write multiple coils
2672 +|=B|3x_Bit|DDDDDdd|0 ~~ 6553515|Input register bit (read only)
2673 +|=W|%MW|DDDDDD|0 ~~ 999999|Output register
2674 +|=DW|%MD|DDDDDD|0 ~~ 999999|Output register
2675 +|=W|3x|DDDDD|0 ~~ 65535|Input Register (read only)
2676 +|=DW|5x|DDDDD|0 ~~ 65535|4x double word swap
2677 +|=DW|6x|DDDDD|0 ~~ 65535|4x single word write
2669 2669  
2670 2670  **Wiring Diagram**