... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Stone
Content
... ... @@ -85,6 +85,182 @@
85 85  
86 86  Click [OK] button to save settings and close the dialog;
87 87  
88 += Create communication with WECON PLC =
89 +
90 +== HMI settings ==
91 +
92 +**Download PIStudio Software**
93 +
94 +Please visit the link below to get the latest version PIstudio for HMI programming:
95 +
96 +* [[Download>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]] or [[Download>>https://drive.google.com/open?id=1Im7YS2rtnRI7yFIHmqHDVPBUyWahqSXN]]
97 +
98 +**Create a new HMI project connect with PLC**
99 +
100 +Check the link below for the video to show you how to get started with a new project
101 +
102 +* [[Video>>https://drive.google.com/open?id=0B0j9uum1UPXbMENtRlF2VzdQdHc]]
103 +
104 +For more videos, please visit our Youtube channel: [[http:~~/~~/www.youtube.com/user/Wecon2004/videos>>url:http://www.youtube.com/user/Wecon2004/videos]]
105 +
106 +**General**
107 +
108 +HMI could communicate with PLC and support many PLC protocols.  It is easy to operate and set communication parameters. This demo shows how to make a communication with PLC device, use WECON LX3V Series PLC as an example.
109 +
110 +**Protocol settings**
111 +
112 +The communication between two devices requires a protocol. The following contents show the steps of protocol settings.
113 +
114 +Please select the protocol, when creating a new project.
115 +
116 +1. Select the COM port for communication;
117 +1. PLC type: It means PLC brand, like WECON;
118 +1. PLC model: It shows the model of PLC, such as LX3V;
119 +
120 +(% style="text-align:center" %)
121 +[[image:image-20220819093729-1.png]]
122 +
123 +If you want to change the protocol for existing project, please click [Program] → [Communication] to open the [Communication] windows, shown as the following figure.
124 +
125 +(% style="text-align:center" %)
126 +[[image:image-20220819093729-2.png]]
127 +
128 +
129 +The steps to change the protocol for project are as follows.
130 +
131 +1. Click [Setting] to open the [Communication device] window;
132 +1. Select communication port, such as COM1;
133 +1. Select Serial port for communication, such as RS422;
134 +1. Select device type (device brand), such as WECON;
135 +1. Select the protocol for communication, such as WECON LX3V;
136 +
137 +(% style="text-align:center" %)
138 +[[image:image-20220819093729-3.png]]
139 +
140 +**Parameter settings**
141 +
142 +The parameters settings are in [Communication] window, shown as following below.
143 +
144 +1. Click [Setting] to open the [COM port setting] window;
145 +1. Set the parameters such as [connection], [Baud rate] and so on;
146 +
147 +(% style="text-align:center" %)
148 +[[image:image-20220819093729-4.png||height="636" width="818"]]
149 +
150 +(% start="3" %)
151 +1. Click [Setting] to open [Timeout] setting window, you could set the parameters according your requirements, or just use the default value.
152 +
153 +(% style="text-align:center" %)
154 +[[image:image-20220819093729-5.png]]
155 +
156 +**Set PLC address in HMI screen**
157 +
158 +1. Place the objects to HMI screen;
159 +1. Double-click the object to open the setting window;
160 +1. Click “Edit” to open the address setting windows;
161 +1. Connection: select the serial port in HMI;
162 +1. Address type: All the PLC address types will be display in this list, such as M;
163 +1. Address No.: Please input the number of this address, such as 0;
164 +
165 +[[image:image-20220819093729-6.jpeg]]
166 +
167 +**Communication cable**
168 +
169 +In order to ensure the stability of communication, please use the twisted-pair communication cable with good grounding. The following figure shows the pin out definition.
170 +
171 +(% style="text-align:center" %)
172 +[[image:image-20220819093729-7.png]]
173 +
174 +**HMI communication PLC use Modbus **
175 +
176 +* HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
177 +* PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
178 +
179 +== PLC settings ==
180 +
181 +**Download PLC Software**
182 +
183 +Please visit below link to get the latest version PLC Editor for HMI programming
184 +
185 +* LX3V:[[Download link>>doc:PLC Editor.10 Hardware .Software.WebHome]]
186 +* LX5V:[[Download link>>doc:PLC Editor2.Download.03 Software.WebHome]]
187 +
188 +**Start a new PLC project**
189 +
190 +Start a new PLC project by clicking “New” on the left top corner of screen, select the PLC mode from the drop-down list.
191 +
192 +(% style="text-align:center" %)
193 +[[image:image-20220819101447-3.jpeg]]
194 +
195 +
196 +
197 +**Add a new instruction **
198 +
199 +Double click on the ladder, select the ladder symbol (instruction) from the drop-down list, then enter the address for this symbol.
200 +
201 +(% style="text-align:center" %)
202 +[[image:image-20220819105530-1.png]]
203 +
204 +You could also select the ladder symbol from the menu bar directly.
205 +
206 +[[image:image-20220819093729-11.png]]
207 +
208 +[[image:image-20220819093729-12.png]]
209 +
210 +**Add comment to PLC program**
211 +
212 +(% style="text-align:center" %)
213 +[[image:image-20220819105630-3.png]]
214 +
215 +**Add the statement to PLC program**
216 +
217 +Add the statement by single click on “Statement”, when finished, single click on “Statement” again to go back to Ladder edit.
218 +
219 +(% style="text-align:center" %)
220 +[[image:image-20220819105644-4.png]]
221 +
222 +**Compile **
223 +
224 +You need to compile the PLC program before downloading or running Off-line simulator. The background color will be changed from purple to white when there is no error.
225 +
226 +[[image:image-20220819093729-15.png]]
227 +
228 +**Download setting **
229 +
230 +Click on “Transfer Setup” to select download mode.
231 +
232 +[[image:image-20220820150853-1.png]]**Download PLC program to PLC**
233 +
234 +Quick select the parameters and main program of PLC program, then download to PLC, “Yes”-”Yes”-”OK”
235 +
236 +[[image:image-20220819093729-17.png]]
237 +
238 +**Upload PLC program from PLC**
239 +
240 +Read the PLC program from PLC to computer.
241 +
242 +[[image:image-20220819093729-18.png]]
243 +
244 +**Device monitor**
245 +
246 +Monitor the value of certain address in PLC, double click “Current value” to change the value in this address.
247 +
248 +[[image:image-20220819093730-19.png]]
249 +
250 +**Online monitor**
251 +
252 +Monitor the each address in PLC by online monitor. Changing the state or value in PLC is also allowd.
253 +
254 +[[image:image-20220819093730-20.png]]
255 +
256 +**Monitor edit**
257 +
258 +In this mode, you could edit the PLC program during PLC is running. 
259 +
260 +
261 +(% style="text-align:center" %)
262 +[[image:image-20220819105928-9.png||height="229" width="669"]]
263 +
88 88  = **Allen-Bradley** =
89 89  
90 90  == **FreeTag Ethernet/IP (CompactLogix)** ==
... ... @@ -2303,9 +2303,6 @@
2303 2303  * **RS485**
2304 2304  
2305 2305  (% style="text-align:center" %)
2306 -[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2307 -
2308 -(% style="text-align:center" %)
2309 2309  [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2310 2310  
2311 2311  * **RS422**
... ... @@ -2321,7 +2321,7 @@
2321 2321  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2322 2322  
2323 2323  
2324 -== HMI and Wecon LX5V serial communication ==
2497 +== **HMI and Wecon LX5V serial communication** ==
2325 2325  
2326 2326  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2327 2327  
... ... @@ -2399,7 +2399,7 @@
2399 2399  
2400 2400  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2401 2401  
2402 -== HMI and Wecon LX5V-N Ethernet communication ==