Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
From version 37.1
edited by Ben
on 2022/08/20 16:50
on 2022/08/20 16:50
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Stone - Content
-
... ... @@ -2303,6 +2303,9 @@ 2303 2303 * **RS485** 2304 2304 2305 2305 (% style="text-align:center" %) 2306 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 2307 + 2308 +(% style="text-align:center" %) 2306 2306 [[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 2307 2307 2308 2308 * **RS422** ... ... @@ -2317,159 +2317,6 @@ 2317 2317 2318 2318 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 2319 2319 2320 - 2321 -== **HMI and Wecon LX5V serial communication** == 2322 - 2323 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2324 - 2325 -**Software configuration of PLC** 2326 - 2327 -**1)PLC programming software** 2328 - 2329 -[[image:image-20220810164710-1.png]] 2330 - 2331 -**2)New PLC project** 2332 - 2333 -Click New Project and select the PLC model. 2334 - 2335 -[[image:image-20220810172412-1.png]] 2336 - 2337 - 2338 -**3)Set Serial port parameters** 2339 - 2340 -Follow the steps below to configure Serial port parameters 2341 - 2342 -Baud rate:115200 2343 - 2344 -Data bit:8 2345 - 2346 -Stop bit:1 2347 - 2348 -Parity:No verification 2349 - 2350 -[[image:image-20220810165759-3.png]] 2351 - 2352 - 2353 -**4)Registers list** 2354 - 2355 -[[image:image-20220811102219-3.png]] 2356 - 2357 - 2358 -**HMI software configuration** 2359 - 2360 -**1)HMI programming software** 2361 - 2362 - [[image:image-20220810171237-4.png]] 2363 - 2364 -**2)New HMI project** 2365 - 2366 -Click New Project and select the HMI model. 2367 - 2368 -[[image:image-20220810172010-5.png]] 2369 - 2370 -**3)Set communication port parameters** 2371 - 2372 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2373 - 2374 -Baud rate:115200 2375 - 2376 -Data bit:8 2377 - 2378 -Stop bit:1 2379 - 2380 -Parity:No verification 2381 - 2382 - 2383 -[[image:image-20220811104012-1.png]] 2384 - 2385 - 2386 -**hardware connection** 2387 - 2388 -**1)Hardware wiring diagram** 2389 - 2390 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2391 - 2392 -[[image:image-20220811103005-4.png]] 2393 - 2394 - 2395 -[[image:image-20220811103227-7.png]] 2396 - 2397 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2398 - 2399 -== **HMI and Wecon LX5V-N Ethernet communication** == 2400 - 2401 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2402 - 2403 - 2404 -**Software configuration of PLC** 2405 - 2406 -**1)PLC programming software** 2407 - 2408 -[[image:image-20220810164710-1.png]] 2409 - 2410 -**2)New PLC project** 2411 - 2412 -Click New Project and select the PLC model. 2413 - 2414 -[[image:image-20220811115454-1.png]] 2415 - 2416 - 2417 -**3)Set Ethernet port parameters** 2418 - 2419 -Follow the steps below to configure Ethernet parameters 2420 - 2421 -PLC IP address:192.168.39.200 2422 - 2423 -default gateway:192.168.39.1 2424 - 2425 -subnet mask:255.255.255.0 2426 - 2427 -[[image:image-20220811140530-2.png]] 2428 - 2429 - 2430 -**4)Registers list** 2431 - 2432 -[[image:image-20220811102219-3.png]] 2433 - 2434 - 2435 -**HMI software configuration** 2436 - 2437 -**1)HMI programming software** 2438 - 2439 - [[image:image-20220810171237-4.png]] 2440 - 2441 -**2)New HMI project** 2442 - 2443 -Click New Project and select the HMI model. 2444 - 2445 -[[image:image-20220810172010-5.png]] 2446 - 2447 -**3)Set communication port parameters** 2448 - 2449 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2450 - 2451 -HMI IP address:192.168.39.201 2452 - 2453 -default gateway:192.168.39.1 2454 - 2455 -subnet mask:255.255.255.0 2456 - 2457 -[[image:image-20220811170753-2.png]] 2458 - 2459 -Next, click Communication Settings to configure the IP of the HMI communication object. 2460 - 2461 -[[image:image-20220811163047-1.png]] 2462 - 2463 -**hardware connection** 2464 - 2465 -**1)Hardware wiring diagram** 2466 - 2467 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2468 - 2469 -[[image:image-20220811170248-1.png]] 2470 - 2471 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2472 - 2473 2473 = **Printer** = 2474 2474 2475 2475 == **TSPL label printer** == ... ... @@ -2637,20 +2637,174 @@ 2637 2637 2638 2638 **✎Note:** COM3 only available in PI8000/PI9000 series. 2639 2639 2490 +== HMI and Wecon LX5V serial communication == 2640 2640 2492 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2493 + 2494 +**Software configuration of PLC** 2495 + 2496 +**1)PLC programming software** 2497 + 2498 +[[image:image-20220810164710-1.png]] 2499 + 2500 +**2)New PLC project** 2501 + 2502 +Click New Project and select the PLC model. 2503 + 2504 +[[image:image-20220810172412-1.png]] 2505 + 2506 + 2507 +**3)Set Serial port parameters** 2508 + 2509 +Follow the steps below to configure Serial port parameters 2510 + 2511 +Baud rate:115200 2512 + 2513 +Data bit:8 2514 + 2515 +Stop bit:1 2516 + 2517 +Parity:No verification 2518 + 2519 +[[image:image-20220810165759-3.png]] 2520 + 2521 + 2522 +**4)Registers list** 2523 + 2524 +[[image:image-20220811102219-3.png]] 2525 + 2526 + 2527 +**HMI software configuration** 2528 + 2529 +**1)HMI programming software** 2530 + 2531 + [[image:image-20220810171237-4.png]] 2532 + 2533 +**2)New HMI project** 2534 + 2535 +Click New Project and select the HMI model. 2536 + 2537 +[[image:image-20220810172010-5.png]] 2538 + 2539 +**3)Set communication port parameters** 2540 + 2541 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 2542 + 2543 +Baud rate:115200 2544 + 2545 +Data bit:8 2546 + 2547 +Stop bit:1 2548 + 2549 +Parity:No verification 2550 + 2551 + 2552 +[[image:image-20220811104012-1.png]] 2553 + 2554 + 2555 +**hardware connection** 2556 + 2557 +**1)Hardware wiring diagram** 2558 + 2559 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 2560 + 2561 +[[image:image-20220811103005-4.png]] 2562 + 2563 + 2564 +[[image:image-20220811103227-7.png]] 2565 + 2566 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 2567 + 2568 +== HMI and Wecon LX5V-N Ethernet communication == 2569 + 2570 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 2571 + 2572 + 2573 +**Software configuration of PLC** 2574 + 2575 +**1)PLC programming software** 2576 + 2577 +[[image:image-20220810164710-1.png]] 2578 + 2579 +**2)New PLC project** 2580 + 2581 +Click New Project and select the PLC model. 2582 + 2583 +[[image:image-20220811115454-1.png]] 2584 + 2585 + 2586 +**3)Set Ethernet port parameters** 2587 + 2588 +Follow the steps below to configure Ethernet parameters 2589 + 2590 +PLC IP address:192.168.39.200 2591 + 2592 +default gateway:192.168.39.1 2593 + 2594 +subnet mask:255.255.255.0 2595 + 2596 +[[image:image-20220811140530-2.png]] 2597 + 2598 + 2599 +**4)Registers list** 2600 + 2601 +[[image:image-20220811102219-3.png]] 2602 + 2603 + 2604 +**HMI software configuration** 2605 + 2606 +**1)HMI programming software** 2607 + 2608 + [[image:image-20220810171237-4.png]] 2609 + 2610 +**2)New HMI project** 2611 + 2612 +Click New Project and select the HMI model. 2613 + 2614 +[[image:image-20220810172010-5.png]] 2615 + 2616 +**3)Set communication port parameters** 2617 + 2618 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 2619 + 2620 +HMI IP address:192.168.39.201 2621 + 2622 +default gateway:192.168.39.1 2623 + 2624 +subnet mask:255.255.255.0 2625 + 2626 +[[image:image-20220811170753-2.png]] 2627 + 2628 +Next, click Communication Settings to configure the IP of the HMI communication object. 2629 + 2630 +[[image:image-20220811163047-1.png]] 2631 + 2632 +**hardware connection** 2633 + 2634 +**1)Hardware wiring diagram** 2635 + 2636 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 2637 + 2638 +[[image:image-20220811170248-1.png]] 2639 + 2640 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 2641 + 2641 2641 = **Schneider MODBUS RTU** = 2642 2642 2643 2643 **HMI Setting** 2644 2644 2645 -|=**Parameters**|=**Recommended**|=**Notes** 2646 -|**P rotocol**|(% colspan="1" %)Schneider MODBUS RTU|2647 -|C onnection|RS485|2648 -|**Baud rate**|19200| 2649 -|**Data bit**|8| 2650 -|**Parity**|Even| 2651 -|**Stop bit**|1| 2652 -|**PLC sta tionNo.**|1|2646 +|=(% scope="row" %)**Parameters**|=**Recommended**|=**Options**|=**Notes** 2647 +|=**PLC type**|(% colspan="2" %)Schneider MODBUS RTU| 2648 +|=**PLC I/F**|RS485|RS232/RS485| 2649 +|=**Baud rate**|19200|9600~~115200| 2650 +|=**Data bits**|8|7,8| 2651 +|=**Parity**|Even|Even, Odd, None| 2652 +|=**Stop bits**|1|1,2| 2653 +|=**PLC sta. no.**|1|0-255| 2653 2653 2655 +|=(% scope="row" style="width: 266px;" %)**Online simulator**|(% style="width:319px" %)YES|(% style="width:336px" %)**Broadcast command**|(% style="width:155px" %)YES 2656 +|=(% style="width: 266px;" %)**Extend address mode**|(% style="width:319px" %)YES|(% style="width:336px" %) |(% style="width:155px" %) 2657 + 2654 2654 **PLC Setting** 2655 2655 2656 2656 |=(% scope="row" %)**Communication mode**|Modbus RTU protocol ... ... @@ -2657,12 +2657,20 @@ 2657 2657 2658 2658 **Device Address** 2659 2659 2660 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 2661 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 2662 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 2663 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 2664 -|W|MW|DDDDDD|0 ~~ 999999|Output register 2665 -|DW|MD|DDDDDD|0 ~~ 999999|Output register 2664 +|=(% scope="row" %)**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 2665 +|=B|%IX|DDDDDo|0 ~~ 655357|Input bit (read only) 2666 +|=B|%QX|DDDDDo|0 ~~ 655357|Write multiple coils 2667 +|=B|%MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 2668 +|=B|%M|DDDDD|0 ~~ 65535|Output bit 2669 +|=B|%MW_Bit|DDDDDdd|0 ~~ 6553515|Output register bit (decimal) 2670 +|=B|1x|DDDDD|0 ~~ 65535|Input bit (read only) 2671 +|=B|0x_multi_coils|DDDDD|0 ~~ 65535|Write multiple coils 2672 +|=B|3x_Bit|DDDDDdd|0 ~~ 6553515|Input register bit (read only) 2673 +|=W|%MW|DDDDDD|0 ~~ 999999|Output register 2674 +|=DW|%MD|DDDDDD|0 ~~ 999999|Output register 2675 +|=W|3x|DDDDD|0 ~~ 65535|Input Register (read only) 2676 +|=DW|5x|DDDDD|0 ~~ 65535|4x double word swap 2677 +|=DW|6x|DDDDD|0 ~~ 65535|4x single word write 2666 2666 2667 2667 **Wiring Diagram** 2668 2668