87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 -== HMI settings ==
90 +== **LX3V Serial Protocol** ==
91 91  
92 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
93 +
94 +**HMI Settings**
95 +
96 +(% class="table-bordered" %)
97 +|**Item**|**Settings**|**Note**
98 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
99 +|Connection|RS422/RS485|
100 +|Baud rate|9600|
101 +|Data bit|7|
102 +|Parity|EVEN|
103 +|Stop bit|1|
104 +|PLC station No.|1|
105 +
106 +**Address List**
107 +
108 +(% class="table-bordered" %)
109 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
110 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
111 +|Y|Y|Y o|0~~303237|
112 +|M|M|M d|0~~99999|
113 +|T|T|T d|0~~99999|
114 +|C|C|C d|0~~99999|
115 +|S|S|S d|0~~99999|
116 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
117 +|Y|Y|Y o|0~~303237|
118 +|M|M|M d|0~~99999|
119 +|T|T|T d|0~~99999|
120 +|C|C|C d|0~~199|
121 +|D|D|D d|0~~7999|
122 +|S|S|S d|0~~99999|
123 +|SD|SD|SD d|8000~~9999|
124 +
125 +**Cable Wiring**
126 +
127 +* **RS485**
128 +
129 +(% style="text-align:center" %)
130 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
131 +
132 +* **RS422**
133 +
134 +(% style="text-align:center" %)
135 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
136 +
137 +**✎Note:**
138 +
139 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
140 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
141 +
142 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
143 +
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
146 +
92 92  **Download PIStudio Software**
93 93  
94 94  Please visit the link below to get the latest version PIstudio for HMI programming:
95 95  
96 -* [[Download>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]] or [[Download>>https://drive.google.com/open?id=1Im7YS2rtnRI7yFIHmqHDVPBUyWahqSXN]]
151 +* [[Download link>>doc:PIStudio.Download.3 Software.WebHome]]
97 97  
98 98  **Create a new HMI project connect with PLC**
99 99  
100 100  Check the link below for the video to show you how to get started with a new project
101 101  
102 -* [[Video>>https://drive.google.com/open?id=0B0j9uum1UPXbMENtRlF2VzdQdHc]]
157 +* [[Video>>https://youtu.be/0FpmDZe_8U8]]
103 103  
104 104  For more videos, please visit our Youtube channel: [[http:~~/~~/www.youtube.com/user/Wecon2004/videos>>url:http://www.youtube.com/user/Wecon2004/videos]]
105 105  
... ... @@ -176,7 +176,8 @@
176 176  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
177 177  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
178 178  
179 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
180 180  
181 181  **Download PLC Software**
182 182  
... ... @@ -261,67 +261,161 @@
261 261  (% style="text-align:center" %)
262 262  [[image:image-20220819105928-9.png||height="229" width="669"]]
263 263  
264 -= **Allen-Bradley** =
320 +== **LX5V Serial Protocol** ==
265 265  
266 -== **FreeTag Ethernet/IP (CompactLogix)** ==
322 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
267 267  
268 -Allen-Brandly CompactLogix
324 +**Software configuration of PLC**
269 269  
270 -**HMI Settings**
326 +**1)PLC programming software**
271 271  
272 -(% class="table-bordered" %)
273 -|**Items**|**Settings**|**Note**
274 -|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)|
275 -|Connection|Ethernet|
276 -|Port No.|44818|
328 +[[image:image-20220810164710-1.png]]
277 277  
278 -**PLC Setting**
330 +**2)New PLC project**
279 279  
280 -Create new tags
332 +Click New Project and select the PLC model.
281 281  
282 -(% style="text-align:center" %)
283 -[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]
334 +[[image:image-20220810172412-1.png]]
284 284  
285 -Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
286 286  
287 -(% style="text-align:center" %)
288 -[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]
337 +**3)Set Serial port parameters**
289 289  
290 -Import labels, please open [Communication] window and click [Import label];
339 +Follow the steps below to configure Serial port parameters
291 291  
292 -Select csv file, all tags will be displayed as belows;
341 +Baud rate:115200
293 293  
294 -(% style="text-align:center" %)
295 -[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]
343 +Data bit:8
296 296  
297 -**✎Note:**
345 +Stop bit:1
298 298  
299 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
347 +Parity:No verification
300 300  
301 -(% style="text-align:center" %)
302 -[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]
349 +[[image:image-20220810165759-3.png]]
303 303  
304 -The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
305 305  
306 -**Communication settings in HMI**
352 +**4)Registers list**
307 307  
308 -Enable HMI Ethernet in [Project Settings];
354 +[[image:image-20220811102219-3.png]]
309 309  
310 -(% style="text-align:center" %)
311 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]]
312 312  
313 -Set PLC IP in [Device IP] settings;
357 +**HMI software configuration**
314 314  
315 -(% style="text-align:center" %)
316 -[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
359 +**1)HMI programming software**
317 317  
318 -**Cable Wiring**
361 + [[image:image-20220810171237-4.png]]
319 319  
320 -(% style="text-align:center" %)
321 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
363 +**2)New HMI project**
322 322  
323 -== **MicroLogix** ==
365 +Click New Project and select the HMI model.
324 324  
367 +[[image:image-20220810172010-5.png]]
368 +
369 +**3)Set communication port parameters**
370 +
371 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
372 +
373 +Baud rate:115200
374 +
375 +Data bit:8
376 +
377 +Stop bit:1
378 +
379 +Parity:No verification
380 +
381 +
382 +[[image:image-20220811104012-1.png]]
383 +
384 +
385 +**hardware connection**
386 +
387 +**1)Hardware wiring diagram**
388 +
389 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
390 +
391 +[[image:image-20220811103005-4.png]]
392 +
393 +
394 +[[image:image-20220811103227-7.png]]
395 +
396 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
397 +
398 +== **LX5V-N Ethernet protocol** ==
399 +
400 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 +
402 +**Software configuration of PLC**
403 +
404 +**1)PLC programming software**
405 +
406 +[[image:image-20220810164710-1.png]]
407 +
408 +**2)New PLC project**
409 +
410 +Click New Project and select the PLC model.
411 +
412 +[[image:image-20220811115454-1.png]]
413 +
414 +
415 +**3)Set Ethernet port parameters**
416 +
417 +Follow the steps below to configure Ethernet parameters
418 +
419 +PLC IP address:192.168.39.200
420 +
421 +default gateway:192.168.39.1
422 +
423 +subnet mask:255.255.255.0
424 +
425 +[[image:image-20220811140530-2.png]]
426 +
427 +
428 +**4)Registers list**
429 +
430 +[[image:image-20220811102219-3.png]]
431 +
432 +
433 +**HMI software configuration**
434 +
435 +**1)HMI programming software**
436 +
437 + [[image:image-20220810171237-4.png]]
438 +
439 +**2)New HMI project**
440 +
441 +Click New Project and select the HMI model.
442 +
443 +[[image:image-20220810172010-5.png]]
444 +
445 +**3)Set communication port parameters**
446 +
447 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
448 +
449 +HMI IP address:192.168.39.201
450 +
451 +default gateway:192.168.39.1
452 +
453 +subnet mask:255.255.255.0
454 +
455 +[[image:image-20220811170753-2.png]]
456 +
457 +Next, click Communication Settings to configure the IP of the HMI communication object.
458 +
459 +[[image:image-20220811163047-1.png]]
460 +
461 +**hardware connection**
462 +
463 +**1)Hardware wiring diagram**
464 +
465 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
466 +
467 +[[image:image-20220811170248-1.png]]
468 +
469 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
470 +
471 += Create communication with **Rockwell PLC** =
472 +
473 +== **MicroLogix Protocol** ==
474 +
325 325  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
326 326  
327 327  **HMI Settings**
... ... @@ -357,9 +357,67 @@
357 357  
358 358  **Cable Wiring**
359 359  
510 +
360 360  (% style="text-align:center" %)
361 361  [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
362 362  
514 +== **FreeTag Ethernet/IP (CompactLogix)** ==
515 +
516 +Allen-Brandly CompactLogix
517 +
518 +**HMI Settings**
519 +
520 +(% class="table-bordered" %)
521 +|**Items**|**Settings**|**Note**
522 +|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)|
523 +|Connection|Ethernet|
524 +|Port No.|44818|
525 +
526 +**PLC Setting**
527 +
528 +Create new tags
529 +
530 +(% style="text-align:center" %)
531 +[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]
532 +
533 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
534 +
535 +(% style="text-align:center" %)
536 +[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]
537 +
538 +Import labels, please open [Communication] window and click [Import label];
539 +
540 +Select csv file, all tags will be displayed as belows;
541 +
542 +(% style="text-align:center" %)
543 +[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]
544 +
545 +**✎Note:**
546 +
547 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
548 +
549 +(% style="text-align:center" %)
550 +[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]
551 +
552 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
553 +
554 +**Communication settings in HMI**
555 +
556 +Enable HMI Ethernet in [Project Settings];
557 +
558 +(% style="text-align:center" %)
559 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]]
560 +
561 +Set PLC IP in [Device IP] settings;
562 +
563 +(% style="text-align:center" %)
564 +[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
565 +
566 +**Cable Wiring**
567 +
568 +(% style="text-align:center" %)
569 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
570 +
363 363  == **AB PLC address edit** ==
364 364  
365 365  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -369,7 +369,7 @@
369 369  * **Word address S:** The word address ranges from 0 to 255 (decimal).
370 370  * **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal).
371 371  
372 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit tare he same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
580 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
373 373  
374 374  |(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
375 375  |(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15
... ... @@ -377,117 +377,280 @@
377 377  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
378 378  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
379 379  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
380 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
381 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
382 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
383 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
384 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
385 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
386 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
387 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
388 388  
389 -= **Barcode Scanner** =
597 += (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
390 390  
391 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet** ==
392 392  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
393 393  **HMI Setting**
394 394  
395 395  (% class="table-bordered" %)
396 396  |**Items**|**Settings**|**Note**
397 -|Protocol|Barcode Scanner|
398 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
399 399  
400 -**Operating Procedures**
614 +**Address List**
401 401  
402 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
403 403  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
404 404  (% style="text-align:center" %)
405 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
406 406  
407 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
408 408  
409 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
410 410  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
411 411  (% style="text-align:center" %)
412 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
413 413  
414 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
415 415  
416 -* The protocol uploads the information acquired by the USB scanner to the HMI;
417 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
418 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
419 419  
420 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
421 421  
422 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet** ==
423 423  
424 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
425 425  
694 +**HMI Setting**
695 +
426 426  (% class="table-bordered" %)
427 427  |**Items**|**Settings**|**Note**
428 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
429 429  |Connection|Ethernet|
430 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
431 431  
432 432  **Address List**
433 433  
434 434  (% class="table-bordered" %)
435 -|**Type**|**Register**|**Range**|**Format**|**Note**
436 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
437 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
438 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
439 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
440 440  
441 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
442 442  
443 -H2: Unit number
721 +MW2=MB(2~~3)
444 444  
445 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
446 446  
447 -H4: Word number of Module
728 +MD4=MB(4~~7)
448 448  
449 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
450 450  
451 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
452 452  
453 -Slot number 2
740 +**Communication Settings**
454 454  
455 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
456 456  
457 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
458 458  
459 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
460 460  )))
461 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
462 -|R|0 – FF.f (Hex)|R HH.h|
463 -|L|0 - 73FF.f (Hex)|L HHHH.h|
464 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
465 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
466 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
467 467  
468 -H1: Remote number
815 +MW2=MB(2~~3)
469 469  
470 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
471 471  
472 -H3: Slot number
822 +MD4=MB(4~~7)
473 473  
474 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
475 475  
476 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
477 477  
478 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
479 479  
480 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
481 481  
482 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
483 483  )))
484 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
485 -|WR|0 – FFFF (Hex)|WR HHHH|
486 -|WL|0 - 73FF (Hex)|WL HHHH|
487 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
488 488  
489 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
490 490  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
491 491  Enable HMI Ethernet in [Project Settings];
492 492  
493 493  (% style="text-align:center" %)
... ... @@ -496,178 +496,285 @@
496 496  Set PLC IP in [Device IP] settings;
497 497  
498 498  (% style="text-align:center" %)
499 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
500 500  
501 -**PLC Configuration**
872 +**✎Note:**
502 502  
503 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
504 504  
505 -(% style="text-align:center" %)
506 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
507 507  
508 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
509 509  
881 +* Please uncheck [Symbolic access only] option;
882 +
510 510  (% style="text-align:center" %)
511 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
512 512  
513 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
514 514  
515 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
516 516  
517 -Connect with PLC and choose to “online” mode
892 +**Such as:**
518 518  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
519 519  (% style="text-align:center" %)
520 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
521 521  
522 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
523 523  
524 -(% style="text-align:center" %)
525 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
526 526  
527 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
528 528  
529 529  (% style="text-align:center" %)
530 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
531 531  
532 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
533 533  
534 534  (% style="text-align:center" %)
535 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
536 536  
537 -(% style="text-align:center" %)
538 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
539 539  
540 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
541 541  
542 -* Both word registers and bit registers support even continuous read/write functions;
543 -* The range of registers is based on the specific PLC type;
544 -
545 545  **Cable Wiring**
546 546  
547 547  (% style="text-align:center" %)
548 548  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
549 549  
550 -= **IEC60870-5 104 Client** =
925 +== **LOGO Ethernet** ==
551 551  
552 -**HMI Setting**
927 +Supported Series: Siemens Logo 0BA0 series
553 553  
929 +**HMI Settings**
930 +
554 554  (% class="table-bordered" %)
555 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
556 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
557 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
558 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|Siemens LOGO|
934 +|Connection|Ethernet|
935 +|Port No.|102|
936 +|PLC station No.|2|
559 559  
560 560  **Address List**
561 561  
562 562  (% class="table-bordered" %)
563 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
564 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
565 -|(% style="width:461px" %)SCNA|0~~16777215.7
566 -|(% style="width:461px" %)DPTB|0~~16777215.7
567 -|(% style="width:461px" %)DCNA|0~~16777215.7
568 -|(% style="width:461px" %)METF|0~~16777215.7
569 -|(% style="width:461px" %)SENC|0~~16777215.7
570 -|(% style="width:461px" %)SENA|0~~16777215.7
571 -|(% style="width:461px" %)MENA|0~~16777215.7
572 -|(% style="width:461px" %)METD|0~~16777215.7
573 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
574 -|(% style="width:461px" %)SCNA|0~~16777215
575 -|(% style="width:461px" %)DPTB|0~~16777215
576 -|(% style="width:461px" %)DCNA|0~~16777215
577 -|(% style="width:461px" %)SENA|0~~16777215
578 -|(% style="width:461px" %)MENA|0~~16777215
579 -|(% style="width:461px" %)METD|0~~16777215
580 -|(% style="width:461px" %)INRO|0~~16777215
581 -|(% style="width:461px" %)TIMESYN|0~~16777215
582 -|(% style="width:461px" %)TIMEZ|0~~16777215
583 -|(% style="width:461px" %)NTP|0~~16777215
584 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
585 -|(% style="width:461px" %)SENC|0~~16777215
941 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
942 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
943 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
944 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
945 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
946 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
947 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
948 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
949 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
950 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
951 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
952 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
953 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
954 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
955 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
956 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
586 586  
587 -**Address Configuration**
958 +**PLC Settings in LOGO Software:**
588 588  
589 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
960 +Click [Tools]~-~-[Ethernet Connections],shown as below.
590 590  
591 591  (% style="text-align:center" %)
592 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
963 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
593 593  
965 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
966 +
594 594  (% style="text-align:center" %)
595 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
968 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
596 596  
597 -Extended tag name
970 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
598 598  
599 -Address range for the extended tag.
972 +(% style="text-align:center" %)
973 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
600 600  
601 -**Communication Settings**
975 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
602 602  
603 -Enable HMI Ethernet in [Project Settings];
977 +(% style="text-align:center" %)
978 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
604 604  
980 +
605 605  (% style="text-align:center" %)
606 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
982 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
607 607  
984 +
985 +**HMI Communication Settings**
986 +
608 608  Set PLC IP in [Device IP] settings;
609 609  
610 610  (% style="text-align:center" %)
611 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
990 +[[image:SiemensLOGODeviceIP.png]]
612 612  
992 +Enable HMI Ethernet in [Project Settings];
993 +
994 +(% style="text-align:center" %)
995 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
996 +
997 +TSAP setting
998 +
999 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1000 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1001 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1002 +
1003 +**✎Note:**
1004 +
1005 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1006 +
1007 +(% style="text-align:center" %)
1008 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1009 +
1010 +
1011 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1012 +* VW address should be even number.such as VW0, VW2, VW4...
1013 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1014 +* Written value of RTC cannot exceed 255.
1015 +
613 613  **Cable Wiring**
614 614  
615 615  (% style="text-align:center" %)
616 616  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
617 617  
618 -= **LG XGK FEnet Ethernet** =
1021 +== **S7-XXX Ethernet** ==
619 619  
620 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1023 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
621 621  
622 -**HMI Settings**
1025 +**HMI Setting**
623 623  
624 -(% class="table-bordered" %)
625 -|**Items**|**Settings**|**Note**
626 -|Protocol|LG XGK FEnet(Ethernet)|
627 -|Connection|Ethernet|
628 -|Port No.|2004|
1027 +(% class="table-bordered" style="width:823px" %)
1028 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
1029 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
1030 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
1031 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
1032 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
1033 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
629 629  
1035 +Slot from TIA Portal is equal to Device No. of PIStudio
1036 +
1037 +Rack from TIA Portal is equal to HMI No. of PIStudio
1038 +
1039 +(% style="text-align:center" %)
1040 +[[image:S7-XXXCommunication Settings.png]]
1041 +
1042 +(% style="text-align:center" %)
1043 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
1044 +
630 630  **Address List**
631 631  
632 632  (% class="table-bordered" %)
633 -|**Type**|**Register**|**Range**|**Format**|**Note**
634 -|(% rowspan="14" %)Word|P|0~~2047|P d|
635 -|M|0~~2047|M d|
636 -|K|0~~2047|K d|
637 -|F|0~~2047|F d|
638 -|T|0~~2047|T d|
639 -|C|0~~2047|C d|
640 -|Z|0~~127|Z d|
641 -|S|0~~127|S d|
642 -|L|0~~11263|L d|
643 -|N|0~~21503|N d|
644 -|D|0~~32767|D d|
645 -|R|0~~32767|R d|
646 -|ZR|0~~65535|ZR d|
647 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1048 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1049 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
1050 +d:0~-~-9999
648 648  
649 -**✎Note:**
1052 +o:0-7
1053 +)))|
1054 +|Q|Q|Q d.o|(((
1055 +d:0~-~-9999
650 650  
651 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
652 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
653 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1057 +o:0-7
1058 +)))|
1059 +|M|M|M d.o|(((
1060 +d:0~-~-9999
654 654  
655 -**Communication settings in HMI**
1062 +o:0-7
1063 +)))|
1064 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1065 +nn:0-9999,
656 656  
1067 +dddd:0-9999,
1068 +
1069 +o:0-7
1070 +)))|(((
1071 +nn:DB No.
1072 +
1073 +dddd:address value
1074 +
1075 +o: digit address
1076 +)))
1077 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1078 +|M|MW|MW d|d:0-99999|(((
1079 +MW0=MB(0~~1)
1080 +
1081 +MW2=MB(2~~3)
1082 +
1083 +Address value is a multiple of 2
1084 +)))
1085 +|M|MD|MD d|d:0-99999|(((
1086 +MD0=MB(0~~3)
1087 +
1088 +MD4=MB(4~~7)
1089 +
1090 +Address value is a multiple of 4
1091 +)))
1092 +|I|IW|IW d|d:0-99999|
1093 +|Q|QW|QW d|d:0-99999|
1094 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1095 +nn:0-9999
1096 +
1097 +dddd:0-9999
1098 +)))|(((
1099 +nn:DB No.
1100 +
1101 +dddd:address value
1102 +)))
1103 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1104 +nn:0-9999
1105 +
1106 +dddd:0-9999
1107 +)))|(((
1108 +nn:DB No.
1109 +
1110 +dddd:address value
1111 +
1112 +Address value is a multiple of 2
1113 +)))
1114 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1115 +nn:0-9999
1116 +
1117 +dddd:0-9999
1118 +)))|(((
1119 +nn:DB No.
1120 +
1121 +dddd:address value
1122 +
1123 +Address value is a multiple of 4
1124 +)))
1125 +
1126 +**Communication Settings**
1127 +
657 657  Enable HMI Ethernet in [Project Settings];
658 658  
659 659  (% style="text-align:center" %)
660 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1131 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
661 661  
662 662  Set PLC IP in [Device IP] settings;
663 663  
664 664  (% style="text-align:center" %)
665 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1136 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
666 666  
1138 +**✎Note:**
1139 +
1140 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1141 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1142 +
667 667  **Cable Wiring**
668 668  
669 -= **Mitsubishi** =
1145 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
670 670  
1147 += Create communication with **Mitsubishi** =
1148 +
671 671  == **FX1S, 1N, 2N Series** ==
672 672  
673 673  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2439,213 +2439,6 @@
2439 2439  
2440 2440  **✎Note:** COM3 only available in PI8000/PI9000 series.
2441 2441  
2442 -= **WECON PLC** =
2443 -
2444 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
2445 -
2446 -**HMI Settings**
2447 -
2448 -(% class="table-bordered" %)
2449 -|**Item**|**Settings**|**Note**
2450 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
2451 -|Connection|RS422/RS485|
2452 -|Baud rate|9600|
2453 -|Data bit|7|
2454 -|Parity|EVEN|
2455 -|Stop bit|1|
2456 -|PLC station No.|1|
2457 -
2458 -**Address List**
2459 -
2460 -(% class="table-bordered" %)
2461 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
2462 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
2463 -|Y|Y|Y o|0~~303237|
2464 -|M|M|M d|0~~99999|
2465 -|T|T|T d|0~~99999|
2466 -|C|C|C d|0~~99999|
2467 -|S|S|S d|0~~99999|
2468 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
2469 -|Y|Y|Y o|0~~303237|
2470 -|M|M|M d|0~~99999|
2471 -|T|T|T d|0~~99999|
2472 -|C|C|C d|0~~199|
2473 -|D|D|D d|0~~7999|
2474 -|S|S|S d|0~~99999|
2475 -|SD|SD|SD d|8000~~9999|
2476 -
2477 -**Cable Wiring**
2478 -
2479 -* **RS485**
2480 -
2481 -(% style="text-align:center" %)
2482 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2483 -
2484 -* **RS422**
2485 -
2486 -(% style="text-align:center" %)
2487 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
2488 -
2489 -**✎Note:**
2490 -
2491 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
2492 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
2493 -
2494 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2495 -
2496 -
2497 -== **HMI and Wecon LX5V serial communication** ==
2498 -
2499 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2500 -
2501 -**Software configuration of PLC**
2502 -
2503 -**1)PLC programming software**
2504 -
2505 -[[image:image-20220810164710-1.png]]
2506 -
2507 -**2)New PLC project**
2508 -
2509 -Click New Project and select the PLC model.
2510 -
2511 -[[image:image-20220810172412-1.png]]
2512 -
2513 -
2514 -**3)Set Serial port parameters**
2515 -
2516 -Follow the steps below to configure Serial port parameters
2517 -
2518 -Baud rate:115200
2519 -
2520 -Data bit:8
2521 -
2522 -Stop bit:1
2523 -
2524 -Parity:No verification
2525 -
2526 -[[image:image-20220810165759-3.png]]
2527 -
2528 -
2529 -**4)Registers list**
2530 -
2531 -[[image:image-20220811102219-3.png]]
2532 -
2533 -
2534 -**HMI software configuration**
2535 -
2536 -**1)HMI programming software**
2537 -
2538 - [[image:image-20220810171237-4.png]]
2539 -
2540 -**2)New HMI project**
2541 -
2542 -Click New Project and select the HMI model.
2543 -
2544 -[[image:image-20220810172010-5.png]]
2545 -
2546 -**3)Set communication port parameters**
2547 -
2548 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2549 -
2550 -Baud rate:115200
2551 -
2552 -Data bit:8
2553 -
2554 -Stop bit:1
2555 -
2556 -Parity:No verification
2557 -
2558 -
2559 -[[image:image-20220811104012-1.png]]
2560 -
2561 -
2562 -**hardware connection**
2563 -
2564 -**1)Hardware wiring diagram**
2565 -
2566 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2567 -
2568 -[[image:image-20220811103005-4.png]]
2569 -
2570 -
2571 -[[image:image-20220811103227-7.png]]
2572 -
2573 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2574 -
2575 -== **HMI and Wecon LX5V-N Ethernet communication** ==
2576 -
2577 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2578 -
2579 -
2580 -**Software configuration of PLC**
2581 -
2582 -**1)PLC programming software**
2583 -
2584 -[[image:image-20220810164710-1.png]]
2585 -
2586 -**2)New PLC project**
2587 -
2588 -Click New Project and select the PLC model.
2589 -
2590 -[[image:image-20220811115454-1.png]]
2591 -
2592 -
2593 -**3)Set Ethernet port parameters**
2594 -
2595 -Follow the steps below to configure Ethernet parameters
2596 -
2597 -PLC IP address:192.168.39.200
2598 -
2599 -default gateway:192.168.39.1
2600 -
2601 -subnet mask:255.255.255.0
2602 -
2603 -[[image:image-20220811140530-2.png]]
2604 -
2605 -
2606 -**4)Registers list**
2607 -
2608 -[[image:image-20220811102219-3.png]]
2609 -
2610 -
2611 -**HMI software configuration**
2612 -
2613 -**1)HMI programming software**
2614 -
2615 - [[image:image-20220810171237-4.png]]
2616 -
2617 -**2)New HMI project**
2618 -
2619 -Click New Project and select the HMI model.
2620 -
2621 -[[image:image-20220810172010-5.png]]
2622 -
2623 -**3)Set communication port parameters**
2624 -
2625 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2626 -
2627 -HMI IP address:192.168.39.201
2628 -
2629 -default gateway:192.168.39.1
2630 -
2631 -subnet mask:255.255.255.0
2632 -
2633 -[[image:image-20220811170753-2.png]]
2634 -
2635 -Next, click Communication Settings to configure the IP of the HMI communication object.
2636 -
2637 -[[image:image-20220811163047-1.png]]
2638 -
2639 -**hardware connection**
2640 -
2641 -**1)Hardware wiring diagram**
2642 -
2643 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2644 -
2645 -[[image:image-20220811170248-1.png]]
2646 -
2647 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2648 -
2649 2649  = **Printer** =
2650 2650  
2651 2651  == **TSPL label printer** ==
... ... @@ -2846,3 +2846,284 @@
2846 2846  
2847 2847  (% style="text-align:center" %)
2848 2848  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
3120 +
3121 += **Barcode Scanner** =
3122 +
3123 +Supported: DELI 14880 barcode scanner
3124 +
3125 +**HMI Setting**
3126 +
3127 +|**Items**|**Settings**|**Note**
3128 +|Protocol|Barcode Scanner|
3129 +|Connection|USB|
3130 +
3131 +**Operating Procedures**
3132 +
3133 +Select [Barcode Scanner];
3134 +
3135 +(% style="text-align:center" %)
3136 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
3137 +
3138 +Set address for receiving;
3139 +
3140 +Set correct length;
3141 +
3142 +(% style="text-align:center" %)
3143 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
3144 +
3145 +**✎Note:**
3146 +
3147 +* The protocol uploads the information acquired by the USB scanner to the HMI;
3148 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
3149 +* Recommended model: DELI 14880 barcode scanner;
3150 +
3151 += **Hitachi EHV Series (Ethernet)** =
3152 +
3153 +Supported series: Hitachi EHV series
3154 +
3155 +**HMI Settings**
3156 +
3157 +(% class="table-bordered" %)
3158 +|**Items**|**Settings**|**Note**
3159 +|Protocol|Hitachi EHV series|
3160 +|Connection|Ethernet|
3161 +|Port No.|3004~~3007|
3162 +
3163 +**Address List**
3164 +
3165 +(% class="table-bordered" %)
3166 +|**Type**|**Register**|**Range**|**Format**|**Note**
3167 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
3168 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
3169 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
3170 +H1H2H3H4 Module main number
3171 +
3172 +H1: Remote number
3173 +
3174 +H2: Unit number
3175 +
3176 +H3: Slot number
3177 +
3178 +H4: Word number of Module
3179 +
3180 +H Sub number of Module
3181 +
3182 +For example:X21.3
3183 +
3184 +Slot number 2
3185 +
3186 +Word number of module is 1
3187 +
3188 +Bit number of module is 3
3189 +
3190 +Remote number and unit number are 0
3191 +)))
3192 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
3193 +|R|0 – FF.f (Hex)|R HH.h|
3194 +|L|0 - 73FF.f (Hex)|L HHHH.h|
3195 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
3196 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
3197 +H1H2H3H4 Module main number
3198 +
3199 +H1: Remote number
3200 +
3201 +H2: Unit number
3202 +
3203 +H3: Slot number
3204 +
3205 +H4: Word number of module
3206 +
3207 +For example:WX21
3208 +
3209 +Word number of module is 1
3210 +
3211 +Slot number is 2
3212 +
3213 +Remote number and unit number are 0
3214 +)))
3215 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
3216 +|WR|0 – FFFF (Hex)|WR HHHH|
3217 +|WL|0 - 73FF (Hex)|WL HHHH|
3218 +|TC|0 - 2559|TC DDDD|
3219 +
3220 +**Communication settings in HMI**
3221 +
3222 +Enable HMI Ethernet in [Project Settings];
3223 +
3224 +(% style="text-align:center" %)
3225 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3226 +
3227 +Set PLC IP in [Device IP] settings;
3228 +
3229 +(% style="text-align:center" %)
3230 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
3231 +
3232 +**PLC Configuration**
3233 +
3234 +Connect with PLC, select[Online mode];
3235 +
3236 +(% style="text-align:center" %)
3237 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
3238 +
3239 +Set IP address, it is the same LAN parameters with HMI;
3240 +
3241 +(% style="text-align:center" %)
3242 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
3243 +
3244 +3) Save PLC communication parameter, and restart PLC
3245 +
3246 +**PLC Monitor Mode**
3247 +
3248 +Connect with PLC and choose to “online” mode
3249 +
3250 +(% style="text-align:center" %)
3251 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
3252 +
3253 +Open I/O monitor sheet1
3254 +
3255 +(% style="text-align:center" %)
3256 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
3257 +
3258 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
3259 +
3260 +(% style="text-align:center" %)
3261 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
3262 +
3263 +Enter the register address, click OK to view the value of the register.
3264 +
3265 +(% style="text-align:center" %)
3266 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3267 +
3268 +(% style="text-align:center" %)
3269 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3270 +
3271 +**✎Note:**
3272 +
3273 +* Both word registers and bit registers support even continuous read/write functions;
3274 +* The range of registers is based on the specific PLC type;
3275 +
3276 +**Cable Wiring**
3277 +
3278 +(% style="text-align:center" %)
3279 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3280 +
3281 += **IEC60870-5 104 Client** =
3282 +
3283 +**HMI Setting**
3284 +
3285 +(% class="table-bordered" %)
3286 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
3287 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
3288 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
3289 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
3290 +
3291 +**Address List**
3292 +
3293 +(% class="table-bordered" %)
3294 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
3295 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
3296 +|(% style="width:461px" %)SCNA|0~~16777215.7
3297 +|(% style="width:461px" %)DPTB|0~~16777215.7
3298 +|(% style="width:461px" %)DCNA|0~~16777215.7
3299 +|(% style="width:461px" %)METF|0~~16777215.7
3300 +|(% style="width:461px" %)SENC|0~~16777215.7
3301 +|(% style="width:461px" %)SENA|0~~16777215.7
3302 +|(% style="width:461px" %)MENA|0~~16777215.7
3303 +|(% style="width:461px" %)METD|0~~16777215.7
3304 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
3305 +|(% style="width:461px" %)SCNA|0~~16777215
3306 +|(% style="width:461px" %)DPTB|0~~16777215
3307 +|(% style="width:461px" %)DCNA|0~~16777215
3308 +|(% style="width:461px" %)SENA|0~~16777215
3309 +|(% style="width:461px" %)MENA|0~~16777215
3310 +|(% style="width:461px" %)METD|0~~16777215
3311 +|(% style="width:461px" %)INRO|0~~16777215
3312 +|(% style="width:461px" %)TIMESYN|0~~16777215
3313 +|(% style="width:461px" %)TIMEZ|0~~16777215
3314 +|(% style="width:461px" %)NTP|0~~16777215
3315 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
3316 +|(% style="width:461px" %)SENC|0~~16777215
3317 +
3318 +**Address Configuration**
3319 +
3320 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
3321 +
3322 +(% style="text-align:center" %)
3323 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
3324 +
3325 +(% style="text-align:center" %)
3326 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
3327 +
3328 +Extended tag name
3329 +
3330 +Address range for the extended tag.
3331 +
3332 +**Communication Settings**
3333 +
3334 +Enable HMI Ethernet in [Project Settings];
3335 +
3336 +(% style="text-align:center" %)
3337 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3338 +
3339 +Set PLC IP in [Device IP] settings;
3340 +
3341 +(% style="text-align:center" %)
3342 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
3343 +
3344 +**Cable Wiring**
3345 +
3346 +(% style="text-align:center" %)
3347 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3348 +
3349 += **LG XGK FEnet Ethernet** =
3350 +
3351 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
3352 +
3353 +**HMI Settings**
3354 +
3355 +(% class="table-bordered" %)
3356 +|**Items**|**Settings**|**Note**
3357 +|Protocol|LG XGK FEnet(Ethernet)|
3358 +|Connection|Ethernet|
3359 +|Port No.|2004|
3360 +
3361 +**Address List**
3362 +
3363 +(% class="table-bordered" %)
3364 +|**Type**|**Register**|**Range**|**Format**|**Note**
3365 +|(% rowspan="14" %)Word|P|0~~2047|P d|
3366 +|M|0~~2047|M d|
3367 +|K|0~~2047|K d|
3368 +|F|0~~2047|F d|
3369 +|T|0~~2047|T d|
3370 +|C|0~~2047|C d|
3371 +|Z|0~~127|Z d|
3372 +|S|0~~127|S d|
3373 +|L|0~~11263|L d|
3374 +|N|0~~21503|N d|
3375 +|D|0~~32767|D d|
3376 +|R|0~~32767|R d|
3377 +|ZR|0~~65535|ZR d|
3378 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
3379 +
3380 +**✎Note:**
3381 +
3382 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
3383 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
3384 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
3385 +
3386 +**Communication settings in HMI**
3387 +
3388 +Enable HMI Ethernet in [Project Settings];
3389 +
3390 +(% style="text-align:center" %)
3391 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3392 +
3393 +Set PLC IP in [Device IP] settings;
3394 +
3395 +(% style="text-align:center" %)
3396 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
3397 +
3398 +**Cable Wiring**
3399 +
3400 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
image-20220819093729-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220819093729-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +79.4 KB
Content
image-20220819093729-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +147.9 KB
Content
image-20220819093729-15.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +74.6 KB
Content
image-20220819093729-17.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +115.0 KB
Content
image-20220819093729-18.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +112.1 KB
Content
image-20220819093729-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20220819093729-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +44.2 KB
Content
image-20220819093729-4 (1).png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +82.4 KB
Content
image-20220819093729-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +82.4 KB
Content
image-20220819093729-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +6.6 KB
Content
image-20220819093729-6.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +100.2 KB
Content
image-20220819093729-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +46.9 KB
Content
image-20220819093730-19.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +122.5 KB
Content
image-20220819093730-20.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +99.6 KB
Content
image-20220819101447-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +56.6 KB
Content
image-20220819105530-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +1.0 MB
Content
image-20220819105630-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +1.1 MB
Content
image-20220819105644-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +942.6 KB
Content
image-20220819105928-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +72.6 KB
Content
image-20220820150853-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +171.7 KB
Content