Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,6 +87,60 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 +== **LX3V Serial Protocol** == 91 + 92 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 93 + 94 +**HMI Settings** 95 + 96 +(% class="table-bordered" %) 97 +|**Item**|**Settings**|**Note** 98 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 99 +|Connection|RS422/RS485| 100 +|Baud rate|9600| 101 +|Data bit|7| 102 +|Parity|EVEN| 103 +|Stop bit|1| 104 +|PLC station No.|1| 105 + 106 +**Address List** 107 + 108 +(% class="table-bordered" %) 109 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 110 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 111 +|Y|Y|Y o|0~~303237| 112 +|M|M|M d|0~~99999| 113 +|T|T|T d|0~~99999| 114 +|C|C|C d|0~~99999| 115 +|S|S|S d|0~~99999| 116 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 117 +|Y|Y|Y o|0~~303237| 118 +|M|M|M d|0~~99999| 119 +|T|T|T d|0~~99999| 120 +|C|C|C d|0~~199| 121 +|D|D|D d|0~~7999| 122 +|S|S|S d|0~~99999| 123 +|SD|SD|SD d|8000~~9999| 124 + 125 +**Cable Wiring** 126 + 127 +* **RS485** 128 + 129 +(% style="text-align:center" %) 130 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 131 + 132 +* **RS422** 133 + 134 +(% style="text-align:center" %) 135 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 136 + 137 +**✎Note:** 138 + 139 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 140 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 141 + 142 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 143 + 90 90 == HMI settings == 91 91 92 92 **Download PIStudio Software** ... ... @@ -261,63 +261,8 @@ 261 261 (% style="text-align:center" %) 262 262 [[image:image-20220819105928-9.png||height="229" width="669"]] 263 263 264 -= ** WECONPLC** =318 +== **LX5V Serial Protocol** == 265 265 266 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 267 - 268 -**HMI Settings** 269 - 270 -(% class="table-bordered" %) 271 -|**Item**|**Settings**|**Note** 272 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 273 -|Connection|RS422/RS485| 274 -|Baud rate|9600| 275 -|Data bit|7| 276 -|Parity|EVEN| 277 -|Stop bit|1| 278 -|PLC station No.|1| 279 - 280 -**Address List** 281 - 282 -(% class="table-bordered" %) 283 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 284 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 285 -|Y|Y|Y o|0~~303237| 286 -|M|M|M d|0~~99999| 287 -|T|T|T d|0~~99999| 288 -|C|C|C d|0~~99999| 289 -|S|S|S d|0~~99999| 290 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 291 -|Y|Y|Y o|0~~303237| 292 -|M|M|M d|0~~99999| 293 -|T|T|T d|0~~99999| 294 -|C|C|C d|0~~199| 295 -|D|D|D d|0~~7999| 296 -|S|S|S d|0~~99999| 297 -|SD|SD|SD d|8000~~9999| 298 - 299 -**Cable Wiring** 300 - 301 -* **RS485** 302 - 303 -(% style="text-align:center" %) 304 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 305 - 306 -* **RS422** 307 - 308 -(% style="text-align:center" %) 309 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 310 - 311 -**✎Note:** 312 - 313 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 314 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 315 - 316 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 317 - 318 - 319 -== **HMI and Wecon LX5V serial communication** == 320 - 321 321 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 322 322 323 323 **Software configuration of PLC** ... ... @@ -394,7 +394,7 @@ 394 394 395 395 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 396 396 397 -== ** HMI and WeconLX5V-N Ethernetcommunication** ==396 +== **LX5V-N Ethernet protocol** == 398 398 399 399 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 400 400 ... ... @@ -468,7 +468,6 @@ 468 468 469 469 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 470 470 471 -(% class="wikigeneratedid" %) 472 472 = = 473 473 474 474 = **Allen-Bradley** =