87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 -== HMI settings ==
90 +== **LX3V Serial Protocol** ==
91 91  
92 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
93 +
94 +**HMI Settings**
95 +
96 +(% class="table-bordered" %)
97 +|**Item**|**Settings**|**Note**
98 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
99 +|Connection|RS422/RS485|
100 +|Baud rate|9600|
101 +|Data bit|7|
102 +|Parity|EVEN|
103 +|Stop bit|1|
104 +|PLC station No.|1|
105 +
106 +**Address List**
107 +
108 +(% class="table-bordered" %)
109 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
110 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
111 +|Y|Y|Y o|0~~303237|
112 +|M|M|M d|0~~99999|
113 +|T|T|T d|0~~99999|
114 +|C|C|C d|0~~99999|
115 +|S|S|S d|0~~99999|
116 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
117 +|Y|Y|Y o|0~~303237|
118 +|M|M|M d|0~~99999|
119 +|T|T|T d|0~~99999|
120 +|C|C|C d|0~~199|
121 +|D|D|D d|0~~7999|
122 +|S|S|S d|0~~99999|
123 +|SD|SD|SD d|8000~~9999|
124 +
125 +**Cable Wiring**
126 +
127 +* **RS485**
128 +
129 +(% style="text-align:center" %)
130 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
131 +
132 +* **RS422**
133 +
134 +(% style="text-align:center" %)
135 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
136 +
137 +**✎Note:**
138 +
139 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
140 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
141 +
142 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
143 +
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
146 +
92 92  **Download PIStudio Software**
93 93  
94 94  Please visit the link below to get the latest version PIstudio for HMI programming:
... ... @@ -176,7 +176,8 @@
176 176  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
177 177  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
178 178  
179 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
180 180  
181 181  **Download PLC Software**
182 182  
... ... @@ -261,63 +261,8 @@
261 261  (% style="text-align:center" %)
262 262  [[image:image-20220819105928-9.png||height="229" width="669"]]
263 263  
264 -= **WECON PLC** =
320 +== **LX5V Serial Protocol** ==
265 265  
266 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
267 -
268 -**HMI Settings**
269 -
270 -(% class="table-bordered" %)
271 -|**Item**|**Settings**|**Note**
272 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
273 -|Connection|RS422/RS485|
274 -|Baud rate|9600|
275 -|Data bit|7|
276 -|Parity|EVEN|
277 -|Stop bit|1|
278 -|PLC station No.|1|
279 -
280 -**Address List**
281 -
282 -(% class="table-bordered" %)
283 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
284 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
285 -|Y|Y|Y o|0~~303237|
286 -|M|M|M d|0~~99999|
287 -|T|T|T d|0~~99999|
288 -|C|C|C d|0~~99999|
289 -|S|S|S d|0~~99999|
290 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
291 -|Y|Y|Y o|0~~303237|
292 -|M|M|M d|0~~99999|
293 -|T|T|T d|0~~99999|
294 -|C|C|C d|0~~199|
295 -|D|D|D d|0~~7999|
296 -|S|S|S d|0~~99999|
297 -|SD|SD|SD d|8000~~9999|
298 -
299 -**Cable Wiring**
300 -
301 -* **RS485**
302 -
303 -(% style="text-align:center" %)
304 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
305 -
306 -* **RS422**
307 -
308 -(% style="text-align:center" %)
309 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
310 -
311 -**✎Note:**
312 -
313 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
314 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
315 -
316 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
317 -
318 -
319 -== **HMI and Wecon LX5V serial communication** ==
320 -
321 321  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
322 322  
323 323  **Software configuration of PLC**
... ... @@ -394,7 +394,7 @@
394 394  
395 395  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
396 396  
397 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
398 398  
399 399  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
400 400  
... ... @@ -468,11 +468,50 @@
468 468  
469 469  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
470 470  
471 -(% class="wikigeneratedid" %)
472 -= =
472 += Create communication with **Rockwell PLC** =
473 473  
474 -= **Allen-Bradley** =
475 475  
475 +== **MicroLogix Protocol** ==
476 +
477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
478 +
479 +**HMI Settings**
480 +
481 +(% class="table-bordered" %)
482 +|**Item**|**Settings**|**Note**
483 +|Protocol|Allen-Bradlley MicroLogix|
484 +|Connection|RS232|
485 +|Baud rate|19200|
486 +|Data bit|8|
487 +|Parity|None|
488 +|Stop bit|1|
489 +|PLC station No.|1|
490 +
491 +**Address List**
492 +
493 +(% class="table-bordered" %)
494 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
496 +|O|O d.d|0.0~~255.15|
497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|S|S d.d|0.0~~255.15|
499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
500 +|(% rowspan="9" %)Word|S|S d|0~~255|
501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
502 +|TP|TP nnhh|0~~ffff
503 +|CS|CS nnhh|0~~ffff
504 +|CP|CP nnhh|0~~ffff
505 +|N|N nnhh|0~~ffff
506 +|C|C nnhh|0~~ffff
507 +|T|T nnhh|0~~ffff
508 +|R|R nnhh|0~~ffff
509 +
510 +**Cable Wiring**
511 +
512 +
513 +(% style="text-align:center" %)
514 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
515 +
476 476  == **FreeTag Ethernet/IP (CompactLogix)** ==
477 477  
478 478  Allen-Brandly CompactLogix
... ... @@ -530,46 +530,6 @@
530 530  (% style="text-align:center" %)
531 531  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
532 532  
533 -== **MicroLogix** ==
534 -
535 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
536 -
537 -**HMI Settings**
538 -
539 -(% class="table-bordered" %)
540 -|**Item**|**Settings**|**Note**
541 -|Protocol|Allen-Bradlley MicroLogix|
542 -|Connection|RS232|
543 -|Baud rate|19200|
544 -|Data bit|8|
545 -|Parity|None|
546 -|Stop bit|1|
547 -|PLC station No.|1|
548 -
549 -**Address List**
550 -
551 -(% class="table-bordered" %)
552 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
553 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
554 -|O|O d.d|0.0~~255.15|
555 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
556 -|S|S d.d|0.0~~255.15|
557 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
558 -|(% rowspan="9" %)Word|S|S d|0~~255|
559 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
560 -|TP|TP nnhh|0~~ffff
561 -|CS|CS nnhh|0~~ffff
562 -|CP|CP nnhh|0~~ffff
563 -|N|N nnhh|0~~ffff
564 -|C|C nnhh|0~~ffff
565 -|T|T nnhh|0~~ffff
566 -|R|R nnhh|0~~ffff
567 -
568 -**Cable Wiring**
569 -
570 -(% style="text-align:center" %)
571 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
572 -
573 573  == **AB PLC address edit** ==
574 574  
575 575  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -596,37 +596,6 @@
596 596  |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 597  |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
598 598  
599 -= **Barcode Scanner** =
600 -
601 -Supported: DELI 14880 barcode scanner
602 -
603 -**HMI Setting**
604 -
605 -(% class="table-bordered" %)
606 -|**Items**|**Settings**|**Note**
607 -|Protocol|Barcode Scanner|
608 -|Connection|USB|
609 -
610 -**Operating Procedures**
611 -
612 -Select [Barcode Scanner];
613 -
614 -(% style="text-align:center" %)
615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
616 -
617 -Set address for receiving;
618 -
619 -Set correct length;
620 -
621 -(% style="text-align:center" %)
622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
623 -
624 -**✎Note:**
625 -
626 -* The protocol uploads the information acquired by the USB scanner to the HMI;
627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 -* Recommended model: DELI 14880 barcode scanner;
629 -
630 630  = **Hitachi EHV Series (Ethernet)** =
631 631  
632 632  Supported series: Hitachi EHV series
... ... @@ -2649,7 +2649,7 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2621 += =
2653 2653  
2654 2654  = **Printer** =
2655 2655