Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 65.1
edited by Ben
on 2022/08/29 14:05
Change comment: There is no comment for this version
To version 123.1
edited by Ben
on 2022/08/30 14:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,7 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 +== **LX3V Serial Protocol** ==
90 90  
91 91  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 92  
... ... @@ -140,7 +140,8 @@
140 140  
141 141  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 142  
143 -== HMI settings ==
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
144 144  
145 145  **Download PIStudio Software**
146 146  
... ... @@ -229,7 +229,8 @@
229 229  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 230  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 231  
232 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
233 233  
234 234  **Download PLC Software**
235 235  
... ... @@ -314,12 +314,8 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **WECON PLC** =
320 +== **LX5V Serial Protocol** ==
318 318  
319 -
320 -
321 -== **HMI and Wecon LX5V serial communication** ==
322 -
323 323  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
324 324  
325 325  **Software configuration of PLC**
... ... @@ -396,11 +396,10 @@
396 396  
397 397  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
398 398  
399 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
400 400  
401 401  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
402 402  
403 -
404 404  **Software configuration of PLC**
405 405  
406 406  **1)PLC programming software**
... ... @@ -470,12 +470,51 @@
470 470  
471 471  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
472 472  
473 -= =
471 += Create communication with **Rockwell PLC** =
474 474  
475 -= **Allen-Bradley** =
473 +== **MicroLogix Protocol** ==
476 476  
477 -== **FreeTag Ethernet/IP (CompactLogix)** ==
475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
478 478  
477 +**HMI Settings**
478 +
479 +(% class="table-bordered" %)
480 +|**Item**|**Settings**|**Note**
481 +|Protocol|Allen-Bradlley MicroLogix|
482 +|Connection|RS232|
483 +|Baud rate|19200|
484 +|Data bit|8|
485 +|Parity|None|
486 +|Stop bit|1|
487 +|PLC station No.|1|
488 +
489 +**Address List**
490 +
491 +(% class="table-bordered" %)
492 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
494 +|O|O d.d|0.0~~255.15|
495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
496 +|S|S d.d|0.0~~255.15|
497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|(% rowspan="9" %)Word|S|S d|0~~255|
499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
500 +|TP|TP nnhh|0~~ffff
501 +|CS|CS nnhh|0~~ffff
502 +|CP|CP nnhh|0~~ffff
503 +|N|N nnhh|0~~ffff
504 +|C|C nnhh|0~~ffff
505 +|T|T nnhh|0~~ffff
506 +|R|R nnhh|0~~ffff
507 +
508 +**Cable Wiring**
509 +
510 +
511 +(% style="text-align:center" %)
512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 +
514 +== **CompactLogix FreeTag Ethernet protocol** ==
515 +
479 479  Allen-Brandly CompactLogix
480 480  
481 481  **HMI Settings**
... ... @@ -531,48 +531,8 @@
531 531  (% style="text-align:center" %)
532 532  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
533 533  
534 -== **MicroLogix** ==
571 +== **MicroLogix 1200** ** protocol** ==
535 535  
536 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
537 -
538 -**HMI Settings**
539 -
540 -(% class="table-bordered" %)
541 -|**Item**|**Settings**|**Note**
542 -|Protocol|Allen-Bradlley MicroLogix|
543 -|Connection|RS232|
544 -|Baud rate|19200|
545 -|Data bit|8|
546 -|Parity|None|
547 -|Stop bit|1|
548 -|PLC station No.|1|
549 -
550 -**Address List**
551 -
552 -(% class="table-bordered" %)
553 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
554 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
555 -|O|O d.d|0.0~~255.15|
556 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
557 -|S|S d.d|0.0~~255.15|
558 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
559 -|(% rowspan="9" %)Word|S|S d|0~~255|
560 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
561 -|TP|TP nnhh|0~~ffff
562 -|CS|CS nnhh|0~~ffff
563 -|CP|CP nnhh|0~~ffff
564 -|N|N nnhh|0~~ffff
565 -|C|C nnhh|0~~ffff
566 -|T|T nnhh|0~~ffff
567 -|R|R nnhh|0~~ffff
568 -
569 -**Cable Wiring**
570 -
571 -(% style="text-align:center" %)
572 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
573 -
574 -== **AB PLC address edit** ==
575 -
576 576  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
577 577  
578 578  * **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal).
... ... @@ -588,117 +588,280 @@
588 588  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
589 589  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
590 590  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
591 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
592 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
593 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
594 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
595 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
596 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
597 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
598 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
599 599  
600 -= **Barcode Scanner** =
597 += Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens PLC** =
601 601  
602 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet Protocol** ==
603 603  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
604 604  **HMI Setting**
605 605  
606 606  (% class="table-bordered" %)
607 607  |**Items**|**Settings**|**Note**
608 -|Protocol|Barcode Scanner|
609 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
610 610  
611 -**Operating Procedures**
614 +**Address List**
612 612  
613 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
614 614  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
615 615  (% style="text-align:center" %)
616 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
617 617  
618 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
619 619  
620 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
621 621  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
622 622  (% style="text-align:center" %)
623 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
624 624  
625 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
626 626  
627 -* The protocol uploads the information acquired by the USB scanner to the HMI;
628 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
629 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
630 630  
631 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
632 632  
633 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet Protocol** ==
634 634  
635 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
636 636  
694 +**HMI Setting**
695 +
637 637  (% class="table-bordered" %)
638 638  |**Items**|**Settings**|**Note**
639 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
640 640  |Connection|Ethernet|
641 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
642 642  
643 643  **Address List**
644 644  
645 645  (% class="table-bordered" %)
646 -|**Type**|**Register**|**Range**|**Format**|**Note**
647 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
648 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
649 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
650 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
651 651  
652 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
653 653  
654 -H2: Unit number
721 +MW2=MB(2~~3)
655 655  
656 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
657 657  
658 -H4: Word number of Module
728 +MD4=MB(4~~7)
659 659  
660 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
661 661  
662 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
663 663  
664 -Slot number 2
740 +**Communication Settings**
665 665  
666 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
667 667  
668 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
669 669  
670 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet Protocol** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
671 671  )))
672 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
673 -|R|0 – FF.f (Hex)|R HH.h|
674 -|L|0 - 73FF.f (Hex)|L HHHH.h|
675 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
676 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
677 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
678 678  
679 -H1: Remote number
815 +MW2=MB(2~~3)
680 680  
681 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
682 682  
683 -H3: Slot number
822 +MD4=MB(4~~7)
684 684  
685 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
686 686  
687 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
688 688  
689 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
690 690  
691 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
692 692  
693 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
694 694  )))
695 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
696 -|WR|0 – FFFF (Hex)|WR HHHH|
697 -|WL|0 - 73FF (Hex)|WL HHHH|
698 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
699 699  
700 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
701 701  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
702 702  Enable HMI Ethernet in [Project Settings];
703 703  
704 704  (% style="text-align:center" %)
... ... @@ -707,180 +707,286 @@
707 707  Set PLC IP in [Device IP] settings;
708 708  
709 709  (% style="text-align:center" %)
710 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
711 711  
712 -**PLC Configuration**
872 +**✎Note:**
713 713  
714 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
715 715  
716 -(% style="text-align:center" %)
717 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
718 718  
719 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
720 720  
881 +* Please uncheck [Symbolic access only] option;
882 +
721 721  (% style="text-align:center" %)
722 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
723 723  
724 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
725 725  
726 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
727 727  
728 -Connect with PLC and choose to “online” mode
892 +**Such as:**
729 729  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
730 730  (% style="text-align:center" %)
731 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
732 732  
733 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
734 734  
735 -(% style="text-align:center" %)
736 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
737 737  
738 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
739 739  
740 740  (% style="text-align:center" %)
741 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
742 742  
743 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
744 744  
745 745  (% style="text-align:center" %)
746 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
747 747  
748 -(% style="text-align:center" %)
749 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
750 750  
751 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
752 752  
753 -* Both word registers and bit registers support even continuous read/write functions;
754 -* The range of registers is based on the specific PLC type;
755 -
756 756  **Cable Wiring**
757 757  
758 758  (% style="text-align:center" %)
759 759  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
760 760  
761 -= **IEC60870-5 104 Client** =
925 +== **S7-XXX Ethernet Protocol** ==
762 762  
927 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 +
763 763  **HMI Setting**
764 764  
765 -(% class="table-bordered" %)
766 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
767 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
768 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
769 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
931 +(% class="table-bordered" style="width:823px" %)
932 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
770 770  
939 +Slot from TIA Portal is equal to Device No. of PIStudio
940 +
941 +Rack from TIA Portal is equal to HMI No. of PIStudio
942 +
943 +(% style="text-align:center" %)
944 +[[image:S7-XXXCommunication Settings.png]]
945 +
946 +(% style="text-align:center" %)
947 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 +
771 771  **Address List**
772 772  
773 773  (% class="table-bordered" %)
774 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
775 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
776 -|(% style="width:461px" %)SCNA|0~~16777215.7
777 -|(% style="width:461px" %)DPTB|0~~16777215.7
778 -|(% style="width:461px" %)DCNA|0~~16777215.7
779 -|(% style="width:461px" %)METF|0~~16777215.7
780 -|(% style="width:461px" %)SENC|0~~16777215.7
781 -|(% style="width:461px" %)SENA|0~~16777215.7
782 -|(% style="width:461px" %)MENA|0~~16777215.7
783 -|(% style="width:461px" %)METD|0~~16777215.7
784 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
785 -|(% style="width:461px" %)SCNA|0~~16777215
786 -|(% style="width:461px" %)DPTB|0~~16777215
787 -|(% style="width:461px" %)DCNA|0~~16777215
788 -|(% style="width:461px" %)SENA|0~~16777215
789 -|(% style="width:461px" %)MENA|0~~16777215
790 -|(% style="width:461px" %)METD|0~~16777215
791 -|(% style="width:461px" %)INRO|0~~16777215
792 -|(% style="width:461px" %)TIMESYN|0~~16777215
793 -|(% style="width:461px" %)TIMEZ|0~~16777215
794 -|(% style="width:461px" %)NTP|0~~16777215
795 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
796 -|(% style="width:461px" %)SENC|0~~16777215
952 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 +d:0~-~-9999
797 797  
798 -**Address Configuration**
956 +o:0-7
957 +)))|
958 +|Q|Q|Q d.o|(((
959 +d:0~-~-9999
799 799  
800 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
961 +o:0-7
962 +)))|
963 +|M|M|M d.o|(((
964 +d:0~-~-9999
801 801  
802 -(% style="text-align:center" %)
803 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
966 +o:0-7
967 +)))|
968 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 +nn:0-9999,
804 804  
805 -(% style="text-align:center" %)
806 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
971 +dddd:0-9999,
807 807  
808 -Extended tag name
973 +o:0-7
974 +)))|(((
975 +nn:DB No.
809 809  
810 -Address range for the extended tag.
977 +dddd:address value
811 811  
979 +o: digit address
980 +)))
981 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 +|M|MW|MW d|d:0-99999|(((
983 +MW0=MB(0~~1)
984 +
985 +MW2=MB(2~~3)
986 +
987 +Address value is a multiple of 2
988 +)))
989 +|M|MD|MD d|d:0-99999|(((
990 +MD0=MB(0~~3)
991 +
992 +MD4=MB(4~~7)
993 +
994 +Address value is a multiple of 4
995 +)))
996 +|I|IW|IW d|d:0-99999|
997 +|Q|QW|QW d|d:0-99999|
998 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 +nn:0-9999
1000 +
1001 +dddd:0-9999
1002 +)))|(((
1003 +nn:DB No.
1004 +
1005 +dddd:address value
1006 +)))
1007 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 +nn:0-9999
1009 +
1010 +dddd:0-9999
1011 +)))|(((
1012 +nn:DB No.
1013 +
1014 +dddd:address value
1015 +
1016 +Address value is a multiple of 2
1017 +)))
1018 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 +nn:0-9999
1020 +
1021 +dddd:0-9999
1022 +)))|(((
1023 +nn:DB No.
1024 +
1025 +dddd:address value
1026 +
1027 +Address value is a multiple of 4
1028 +)))
1029 +
812 812  **Communication Settings**
813 813  
814 814  Enable HMI Ethernet in [Project Settings];
815 815  
816 816  (% style="text-align:center" %)
817 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1035 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
818 818  
819 819  Set PLC IP in [Device IP] settings;
820 820  
821 821  (% style="text-align:center" %)
822 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
1040 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
823 823  
1042 +**✎Note:**
1043 +
1044 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 +
824 824  **Cable Wiring**
825 825  
826 -(% style="text-align:center" %)
827 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1049 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
828 828  
829 -= **LG XGK FEnet Ethernet** =
1051 +== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet Protocol** ==
830 830  
831 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1053 +Supported Series: Siemens Logo 0BA0 series
832 832  
833 833  **HMI Settings**
834 834  
835 835  (% class="table-bordered" %)
836 836  |**Items**|**Settings**|**Note**
837 -|Protocol|LG XGK FEnet(Ethernet)|
1059 +|Protocol|Siemens LOGO|
838 838  |Connection|Ethernet|
839 -|Port No.|2004|
1061 +|Port No.|102|
1062 +|PLC station No.|2|
840 840  
841 841  **Address List**
842 842  
843 843  (% class="table-bordered" %)
844 -|**Type**|**Register**|**Range**|**Format**|**Note**
845 -|(% rowspan="14" %)Word|P|0~~2047|P d|
846 -|M|0~~2047|M d|
847 -|K|0~~2047|K d|
848 -|F|0~~2047|F d|
849 -|T|0~~2047|T d|
850 -|C|0~~2047|C d|
851 -|Z|0~~127|Z d|
852 -|S|0~~127|S d|
853 -|L|0~~11263|L d|
854 -|N|0~~21503|N d|
855 -|D|0~~32767|D d|
856 -|R|0~~32767|R d|
857 -|ZR|0~~65535|ZR d|
858 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1067 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
859 859  
860 -**✎Note:**
1084 +**PLC Settings in LOGO Software:**
861 861  
862 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
863 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
864 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1086 +Click [Tools]~-~-[Ethernet Connections],shown as below.
865 865  
866 -**Communication settings in HMI**
1088 +(% style="text-align:center" %)
1089 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
867 867  
868 -Enable HMI Ethernet in [Project Settings];
1091 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
869 869  
870 870  (% style="text-align:center" %)
871 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1094 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
872 872  
1096 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 +
1098 +(% style="text-align:center" %)
1099 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 +
1101 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 +
1103 +(% style="text-align:center" %)
1104 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 +
1106 +
1107 +(% style="text-align:center" %)
1108 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 +
1110 +
1111 +**HMI Communication Settings**
1112 +
873 873  Set PLC IP in [Device IP] settings;
874 874  
875 875  (% style="text-align:center" %)
876 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1116 +[[image:SiemensLOGODeviceIP.png]]
877 877  
1118 +Enable HMI Ethernet in [Project Settings];
1119 +
1120 +(% style="text-align:center" %)
1121 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 +
1123 +TSAP setting
1124 +
1125 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 +
1129 +**✎Note:**
1130 +
1131 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 +
1133 +(% style="text-align:center" %)
1134 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 +
1136 +
1137 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 +* VW address should be even number.such as VW0, VW2, VW4...
1139 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 +* Written value of RTC cannot exceed 255.
1141 +
878 878  **Cable Wiring**
879 879  
880 -= **Mitsubishi** =
1144 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
881 881  
882 -== **FX1S, 1N, 2N Series** ==
1146 += Create communication with **Mitsubishi PLC** =
883 883  
1148 +== **FX1S, 1N, 2N Series Protocol** ==
1149 +
884 884  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
885 885  
886 886  **HMI Settings**
... ... @@ -932,7 +932,7 @@
932 932  
933 933  **✎Note:** COM3 only available in PI8000/PI9000 series.
934 934  
935 -== **FX5U Ethernet** ==
1201 +== **FX5U Ethernet Protocol** ==
936 936  
937 937  Mitsubishi FX5U series PLC
938 938  
... ... @@ -1011,7 +1011,7 @@
1011 1011  (% style="text-align:center" %)
1012 1012  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1013 1013  
1014 -== **FX5U Serial Port** ==
1280 +== **FX5U Serial Port Protocol** ==
1015 1015  
1016 1016  Mitsubishi FX5U series PLC
1017 1017  
... ... @@ -1103,7 +1103,7 @@
1103 1103  
1104 1104  **✎Note:** COM3 only available in PI8000/PI9000 series.
1105 1105  
1106 -== **L02 MELSEC (Ethernet)** ==
1372 +== **L02 MELSEC (Ethernet) Protocol** ==
1107 1107  
1108 1108  Mitsubishi Q series CPU built-in Ethernet port.
1109 1109  
... ... @@ -1188,7 +1188,7 @@
1188 1188  (% style="text-align:center" %)
1189 1189  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1190 1190  
1191 -== **QJ71E71 MELSEC** ==
1457 +== **QJ71E71 MELSEC Protocol** ==
1192 1192  
1193 1193  Mitsubishi QJ71E71 Ethernet communication module;
1194 1194  
... ... @@ -1268,219 +1268,200 @@
1268 1268  (% style="text-align:center" %)
1269 1269  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1270 1270  
1271 -= **MODBUS** =
1537 += Create communication with **Delta PLC** =
1272 1272  
1273 -== **MODBUS RTU Master** ==
1539 +== **DVP serial protocol** ==
1274 1274  
1275 -Supported Series: MODBUS RTU CONTROLLER
1541 +(% class="wikigeneratedid" %)
1542 +Supported Series: Delta DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX Controller
1276 1276  
1277 -HMI works as MODBUS SLAVE connecting with MASTER
1544 +**1)HMI Settings**
1278 1278  
1279 -(% style="text-align:center" %)
1280 -[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1546 +|**Item**|**Settings**|**Note**
1547 +|Protocol|DELTA DVP Series|
1548 +|Connection|RS485|
1549 +|Baud rate|9600|
1550 +|Data bit|7|
1551 +|Parity|Even|
1552 +|Stop bit|1|
1553 +|PLC station No.|1~~255|Need to be the same as PLC settings
1281 1281  
1555 +**2)Address List**
1282 1282  
1283 -(% style="text-align:center" %)
1284 -[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1557 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1558 +|Bit|X|X|X d|0~~303237|
1559 +|Bit|Y|Y|Y d|0~~303237|
1560 +|Bit|M|M|M d|0~~99999|
1561 +|Bit|T|T|T d|0~~99999|
1562 +|Bit|C|C|T d|0~~99999|
1563 +|Bit|S|S|T d|0~~99999|
1564 +|Word|D|D|D d|0~~99999|
1565 +|Word|T|T|T d|0~~99999|
1566 +|Word|C|C|C d|0~~99999|
1285 1285  
1568 +(% class="wikigeneratedid" %)
1569 +**3)Configure the communication protocol**
1286 1286  
1287 -(% style="text-align:center" %)
1288 -[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1571 +(% class="wikigeneratedid" %)
1572 +[[image:image-20220829152327-6.png]]
1289 1289  
1290 -**HMI Settings**
1574 +(% class="wikigeneratedid" %)
1575 +[[image:image-20220829152016-3.png]]
1291 1291  
1292 -(% class="table-bordered" %)
1293 -|**Items**|**Settings**|**Note**
1294 -|Protocol|MODBUS RTU Master|
1295 -|Connection|RS485/RS232|
1296 -|Baud rate|2400~~187500|
1297 -|Data bit|8|
1298 -|Parity|Even/ Odd/ None|
1299 -|Stop bit|1/2|
1300 -|Station No.|0~~255|
1577 +(% class="wikigeneratedid" %)
1578 +**4)Cable Wiring**
1301 1301  
1302 -**Address List**
1580 +(% class="wikigeneratedid" id="H" %)
1581 +[[image:image-20220829152610-7.png]]
1303 1303  
1304 -(% class="table-bordered" %)
1305 -|**Type**|**HMI address**|**MODBUS code**|**Range**
1306 -|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1307 -|Word|HDW3500~~HDW7999|4|0~~4499
1583 +(% class="wikigeneratedid" id="H" %)
1584 +[[image:image-20220829152102-5.png]]
1308 1308  
1309 -**Cable Wiring**
1310 1310  
1311 -* **RS485**
1587 +== **DVP Ethernet Protocol** ==
1312 1312  
1313 -(% style="text-align:center" %)
1314 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1589 +(% class="wikigeneratedid" %)
1590 +Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller
1315 1315  
1316 -(% style="text-align:center" %)
1317 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1592 +**1)HMI Settings**
1318 1318  
1319 -* **RS232**
1594 +|**Items**|**Settings**|**Note**
1595 +|Protocol|DELTA DVP Modbus TCP|
1596 +|Connection|Ethernet|
1597 +|Port No.|201|Must be the same as the PLC setting
1598 +|PLC station No.|0|Must be the same as the PLC setting
1320 1320  
1321 -(% style="text-align:center" %)
1322 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1600 +**2)Address List**
1323 1323  
1324 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1602 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1603 +|Bit|X|X|X o|0~~377|
1604 +|Bit|Y|Y|Y o|0~~377|
1605 +|Bit|M0|M0|M0 d|0~~1535|
1606 +|Bit|M1|M1|M1 d|1536~~4095|
1607 +|Bit|T|T|T d|0~~255|
1608 +|Bit|C|C|C d|0~~255|
1609 +|Bit|S|S|S d|0~~1023|
1610 +|Word|D0|D0|D0 d|0~~4095|
1611 +|Word|D1|D1|D1 d|4096~~11999|(((
1612 +
1613 +)))
1614 +|Word|T|T|T d|0~~255|
1615 +|Word|C|C|C d|0~~199|(((
1616 +
1617 +)))
1325 1325  
1326 -== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1619 +(% class="wikigeneratedid" %)
1620 +**3)Configure the communication protocol**
1327 1327  
1328 -Supported Series: MODBUS RTU CONTROLLER
1622 +[[image:image-20220829155452-1.png]]
1329 1329  
1330 -HMI works as MODBUS MASTER connecting with SLAVE.
1624 +[[image:image-20220829162116-2.png]]
1331 1331  
1332 -The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1626 +**4)Cable Wiring**
1333 1333  
1334 -(% style="text-align:center" %)
1335 -[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1628 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1336 1336  
1630 +== **AS serial protocol** ==
1337 1337  
1338 -(% style="text-align:center" %)
1339 -[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1632 +**1)HMI Settings**
1340 1340  
1341 -
1342 -(% style="text-align:center" %)
1343 -[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1344 -
1345 -**HMI Settings**
1346 -
1347 -(% class="table-bordered" %)
1348 -|**Items**|**Settings**|**Note**
1349 -|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1350 -|Connection|RS485/RS232|
1351 -|Baud rate|2400~~187500|
1634 +|**Item**|**Settings**|**Note**
1635 +|Protocol|DELTA AS300 MODBUS RTU|
1636 +|Connection|RS485|
1637 +|Baud rate|9600|
1352 1352  |Data bit|8|
1353 -|Parity|Even/ Odd/ None|
1354 -|Stop bit|1/2|
1355 -|PLC station No.|0~~255|
1639 +|Parity|NONE|
1640 +|Stop bit|1|
1641 +|PLC station No.|1|
1356 1356  
1357 -**Address List**
1643 +**2)Address List**
1358 1358  
1359 -(% class="table-bordered" %)
1360 -|**Type**|**Address Type**|**Function code & Description**
1361 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1362 -|06 (write single register: write a binary value to a holding register)
1363 -|10 (write values to multiple addresses )
1364 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1365 -|06 (write single register: write a binary value to a holding register)
1366 -|10 (write values to multiple addresses )
1367 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1368 -|06 (write single register: write a binary value to a holding register)
1369 -|10 (write values to multiple addresses )
1370 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1371 -|10 (write values to multiple addresses )
1372 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1373 -|05 (Force a single coil to force the on/off state of a logic coil)
1374 -|0F (Write multiple bits, ie write continuously)
1375 -|(% rowspan="3" %)1|02 (Read the input state)
1376 -|05 (Force a single coil to force the on/off state of a logic coil)
1377 -|0F (Write multiple bits)
1378 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1379 -|05 (Force a single coil to force the on/off state of a logic coil)
1380 -|0F (Write multiple bits)
1381 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1382 -|0F (Write multiple bits)
1383 1383  
1384 -**✎Note:**
1646 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1647 +|Bit|X|X|X d|0~~63|
1648 +|Bit|Y|Y|Y d|0~~63|
1649 +|Bit|D|D|D d|0~~29999|
1650 +|Bit|M|M|M d|0~~8191|
1651 +|Bit|SM|SM|SM d|0~~4095|
1652 +|Bit|S|S|S h|0~~2047|
1653 +|Bit|T|T|T d|0~~511|
1654 +|Bit|C|C|C d|0~~511|
1655 +|Bit|HC|HC|HC d|0~~255|
1656 +|Word|X|X|X h|0~~63|
1657 +|Word|Y|Y|Y d|0~~63|
1658 +|Word|SR|SR|SR d|0~~2047|
1659 +|Word|D|D|D d|0~~29999|
1660 +|Word|T|T|T d|0~~511|
1661 +|Word|C|C|C h|0~~511|
1662 +|Word|E|E|E d|0~~9|
1385 1385  
1386 -* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1387 -* The function codes sent out are the same as those that read and write words.
1664 +**3)Configure the communication protocol**
1388 1388  
1389 -**Station number for more than one slaves**
1666 +[[image:image-20220830094600-1.png]]
1390 1390  
1391 -If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1668 +[[image:image-20220830094657-2.png]]
1392 1392  
1393 -(% style="text-align:center" %)
1394 -[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1670 +**4)Cable Wiring**
1395 1395  
1396 -**Cable Wiring**
1672 +Figure
1397 1397  
1398 -* **RS485**
1674 +[[image:image-20220830141138-1.png]]
1399 1399  
1400 -(% style="text-align:center" %)
1401 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1676 +Pin Definition Diagram
1402 1402  
1403 -(% style="text-align:center" %)
1404 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1678 +[[image:image-20220830095131-1.png]]
1405 1405  
1406 -* **RS232**
1680 +== **AS Ethernet Protocol** ==
1407 1407  
1408 -(% style="text-align:center" %)
1409 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1682 +**1)HMI Settings**
1410 1410  
1411 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1412 1412  
1413 -== **MODBUS TCP Slave (All function)** ==
1414 -
1415 -Supported series: MODBUS TCP controller
1416 -
1417 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1418 -
1419 -(% style="text-align:center" %)
1420 -[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1421 -
1422 -(% style="text-align:center" %)
1423 -[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1424 -
1425 -
1426 -(% style="text-align:center" %)
1427 -[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1428 -
1429 -**HMI Setting**
1430 -
1431 -(% class="table-bordered" %)
1432 -|**Items**|**Settings**|**Note**
1433 -|Protocol|MODBUS TCP Slave (All function)|
1685 +|=**Items**|=**Settings**|=**Note**
1686 +|Protocol|DELTA AS300 MODBUS TCP|
1434 1434  |Connection|Ethernet|
1435 1435  |Port No.|502|
1436 -|PLC station No.|1|
1689 +|Device No.|1|
1690 +|HMI No.|0|
1437 1437  
1438 -**Address List**
1692 +**2)Address List**
1439 1439  
1440 -(% class="table-bordered" %)
1441 -|**Type**|**Register**|**Function code & Description**
1442 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1443 -|06 (write single register: write a binary value to a holding register)
1444 -|10 (write values to multiple addresses )
1445 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1446 -|06 (write single register: write a binary value to a holding register)
1447 -|10 (write values to multiple addresses )
1448 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1449 -|06 (write single register: write a binary value to a holding register)
1450 -|10 (write values to multiple addresses )
1451 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1452 -|10 (write values to multiple addresses )
1453 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1454 -|05 (Force a single coil to force the on/off state of a logic coil)
1455 -|0F (Write multiple bits, ie write continuously)
1456 -|(% rowspan="3" %)1|02 (Read the input state)
1457 -|05 (Force a single coil to force the on/off state of a logic coil)
1458 -|0F (Write multiple bits)
1459 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1460 -|05 (Force a single coil to force the on/off state of a logic coil)
1461 -|0F (Write multiple bits)
1462 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1463 -|0F (Write multiple bits)
1464 1464  
1465 -**Communication Settings**
1695 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1696 +|Bit|X|X|X d|0~~63|
1697 +|Bit|Y|Y|Y d|0~~63|
1698 +|Bit|D|D|D d|0~~29999|
1699 +|Bit|M|M|M d|0~~8191|
1700 +|Bit|SM|SM|SM d|0~~4095|
1701 +|Bit|S|S|S h|0~~2047|
1702 +|Bit|T|T|T d|0~~511|
1703 +|Bit|C|C|C d|0~~511|
1704 +|Bit|HC|HC|HC d|0~~255|
1705 +|Word|X|X|X h|0~~63|
1706 +|Word|Y|Y|Y d|0~~63|
1707 +|Word|SR|SR|SR d|0~~2047|
1708 +|Word|D|D|D d|0~~29999|
1709 +|Word|T|T|T d|0~~511|
1710 +|Word|C|C|C h|0~~511|
1711 +|Word|E|E|E d|0~~9|
1466 1466  
1467 -Enable HMI Ethernet in [Project Settings];
1713 +**3)Configure the communication protocol**
1468 1468  
1469 -(% style="text-align:center" %)
1470 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1715 +[[image:image-20220830140537-1.png]]
1471 1471  
1472 -Set PLC IP in [Device IP] settings;
1717 +[[image:image-20220830140629-2.png]]
1473 1473  
1474 -(% style="text-align:center" %)
1475 -[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1719 +**4)Cable Wiring**
1476 1476  
1477 -**Cable Wiring**
1721 +Figure
1478 1478  
1479 -(% style="text-align:center" %)
1480 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1723 +[[image:image-20220830094929-1.png]]
1481 1481  
1482 -= **Omron** =
1725 +Pin Definition Diagram
1483 1483  
1727 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1728 +
1729 += ** Omron** =
1730 +
1484 1484  == **EC55** ==
1485 1485  
1486 1486  Supported device: EC55 temperature instrument
... ... @@ -1487,7 +1487,6 @@
1487 1487  
1488 1488  **HMI Settings**
1489 1489  
1490 -(% class="table-bordered" %)
1491 1491  |**Items**|**Settings**|**Note**
1492 1492  |Protocol|Omron EC55|
1493 1493  |Connection|RS485 (9600, 2, 7, EVEN)|
... ... @@ -1496,7 +1496,6 @@
1496 1496  
1497 1497  **Address List**
1498 1498  
1499 -(% class="table-bordered" %)
1500 1500  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1501 1501  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1502 1502  |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
... ... @@ -1542,7 +1542,7 @@
1542 1542  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1543 1543  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1544 1544  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1545 -* (% id="cke_bm_8690S" style="display:none" %)[[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]](%%)Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1790 +* [[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1546 1546  
1547 1547  == EtherNet/IP NX series ==
1548 1548  
... ... @@ -1550,7 +1550,6 @@
1550 1550  
1551 1551  **HMI Setting**
1552 1552  
1553 -(% class="table-bordered" %)
1554 1554  |**Items**|**Settings**|**Note**
1555 1555  |Protocol|Omron NX Ethernet/IP|
1556 1556  |Connection|Ethernet|
... ... @@ -1602,183 +1602,224 @@
1602 1602  (% style="text-align:center" %)
1603 1603  [[image:12.PLC Protocol_html_437cb087b36b5784.png||data-xwiki-image-style-alignment="center" height="330" width="600" class="img-thumbnail"]]
1604 1604  
1605 -
1606 1606  (% style="text-align:center" %)
1607 1607  [[image:12.PLC Protocol_html_60ef71528a99abf5.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1608 1608  
1609 1609  **Cable Wiring**
1610 1610  
1854 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1855 +
1856 += **MODBUS** =
1857 +
1858 +== **MODBUS RTU Master** ==
1859 +
1860 +Supported Series: MODBUS RTU CONTROLLER
1861 +
1862 +HMI works as MODBUS SLAVE connecting with MASTER
1863 +
1611 1611  (% style="text-align:center" %)
1612 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1865 +[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1613 1613  
1614 -= **OpenCAN** =
1615 1615  
1616 -OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
1868 +(% style="text-align:center" %)
1869 +[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1617 1617  
1618 -This protocol is only available in PI8000 series HMI.
1619 1619  
1872 +(% style="text-align:center" %)
1873 +[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1874 +
1620 1620  **HMI Settings**
1621 1621  
1622 1622  (% class="table-bordered" %)
1623 1623  |**Items**|**Settings**|**Note**
1624 -|Protocol|OPENCAN|
1625 -|Connection|CAN port|
1626 -|Baud rate|250000|
1879 +|Protocol|MODBUS RTU Master|
1880 +|Connection|RS485/RS232|
1881 +|Baud rate|2400~~187500|
1882 +|Data bit|8|
1883 +|Parity|Even/ Odd/ None|
1884 +|Stop bit|1/2|
1885 +|Station No.|0~~255|
1627 1627  
1628 -**CAN frame setting in HMI**
1887 +**Address List**
1629 1629  
1630 -Click [OpenCAN setting] button in communication setting window;
1889 +(% class="table-bordered" %)
1890 +|**Type**|**HMI address**|**MODBUS code**|**Range**
1891 +|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1892 +|Word|HDW3500~~HDW7999|4|0~~4499
1631 1631  
1632 -(% style="text-align:center" %)
1633 -[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
1894 +**Cable Wiring**
1634 1634  
1635 -Click [Add] to create a new frame;
1896 +* **RS485**
1636 1636  
1637 1637  (% style="text-align:center" %)
1638 -[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
1899 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1639 1639  
1640 -(% class="table-bordered" %)
1641 -|**No**|**Items**|**Description**
1642 -|1|Add|add a frame related to register address
1643 -|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
1644 -|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
1645 -|4|Modify|Modify the frames in frame management
1646 -|5|Copy|Copy one frame to another
1647 -|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
1648 -|7|Empty|All frames in the list are cleared
1649 -|8|Browse|Displays configuration files in XML format in IE
1650 -|9|OK|Complete the configuration of the frame and exit
1901 +(% style="text-align:center" %)
1902 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1651 1651  
1652 -Set CANBUS frame in setting windows
1904 +* **RS232**
1653 1653  
1654 1654  (% style="text-align:center" %)
1655 -[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
1907 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1656 1656  
1657 -(% class="table-bordered" %)
1658 -|**No**|(% style="width:185px" %)**Items**|(% style="width:854px" %)**Description**
1659 -|1|(% style="width:185px" %)ID|(% style="width:854px" %)Set the ID of a can frame in hexadecimal format;
1660 -|2|(% style="width:185px" %)ID assign|(% style="width:854px" %)split the ID by PF, PS, and SA;
1661 -|3|(% style="width:185px" %)Frame type|(% style="width:854px" %)Select Standard frame or Extended Frame;
1662 -|4|(% style="width:185px" %)Frame format|(% style="width:854px" %)Select between data frame and remote Frame;
1663 -|5|(% style="width:185px" %)Data|(% style="width:854px" %)Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
1664 -|6|(% style="width:185px" %)Use address|(% style="width:854px" %)(((
1665 -Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
1909 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1666 1666  
1667 -**Edit:** Set a bit or word address by its format;
1911 +== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1668 1668  
1669 -**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
1670 -)))
1671 -|(% rowspan="8" %)7|(% rowspan="8" style="width:185px" %)Data interactive configuration|(% style="width:854px" %)There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
1672 -|(% style="width:854px" %)Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
1673 -|(% style="width:854px" %)Feedback mode: feedback mode includes no response, confirm response and data response;
1674 -|(% style="width:854px" %)No response: the device or touch screen will not receive feedback;
1675 -|(% style="width:854px" %)Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
1676 -|(% style="width:854px" %)Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
1677 -|(% style="width:854px" %)response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
1678 -|(% style="width:854px" %)Response timeout: sets whether the response frame timeout;
1679 -|(% rowspan="3" %)8|(% rowspan="3" style="width:185px" %)Control address|(% style="width:854px" %)If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
1680 -|(% style="width:854px" %)Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
1681 -|(% style="width:854px" %)Manually send: a manually send tick indicates only one send;
1682 -|9|(% style="width:185px" %)Flag configuration|(% style="width:854px" %)Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
1683 -|10|(% style="width:185px" %)Note|(% style="width:854px" %)Fill the text to explain the meaning of the frame;
1684 -|11|(% style="width:185px" %)Data assign|(% style="width:854px" %)Preview the display in this table based on the address and the corresponding number of digits;
1685 -|12|(% style="width:185px" %)Current operation display|(% style="width:854px" %)Display the description of current operation;
1686 -|13|(% style="width:185px" %)Add|(% style="width:854px" %)Add a new frame;
1687 -|14|(% style="width:185px" %)Save frame|(% style="width:854px" %)Save the configured frame format;
1688 -|15|(% style="width:185px" %)Cancel|(% style="width:854px" %)Cancel the frame configuration;
1913 +Supported Series: MODBUS RTU CONTROLLER
1689 1689  
1690 -Set CAN address (Read or write operation);
1915 +HMI works as MODBUS MASTER connecting with SLAVE.
1691 1691  
1917 +The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1918 +
1692 1692  (% style="text-align:center" %)
1693 -[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
1920 +[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1694 1694  
1695 -(% class="table-bordered" %)
1696 -|**No.**|(% style="width:207px" %)**Item**|(% style="width:829px" %)**Description**
1697 -|1|(% style="width:207px" %)Current address|(% style="width:829px" %)Displays the register type and register address set by the user in the data access interface
1698 -|(% rowspan="3" %)2|(% rowspan="3" style="width:207px" %)Trigger|(% style="width:829px" %)Two operations, "read" and "write," are based on on-screen registers
1699 -|(% style="width:829px" %)If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
1700 -|(% style="width:829px" %)If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
1701 -|(% rowspan="5" %)3|(% rowspan="3" style="width:207px" %)Data operation|(% style="width:829px" %)The read and write operations in the trigger conditions are set accordingly.
1702 -|(% style="width:829px" %)If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
1703 -|(% style="width:829px" %)If the trigger condition is a writing operation, there are two situations:(((
1704 -* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
1705 -* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
1706 -)))
1707 -|(% rowspan="2" style="width:207px" %)Position and length input format|(% style="width:829px" %)If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
1708 -|(% style="width:829px" %)If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
1709 -|4|(% style="width:207px" %)Add|(% style="width:829px" %)Add current configuration
1710 -|5|(% style="width:207px" %)Close|(% style="width:829px" %)Close the configuration window to exit
1711 1711  
1712 -**Multiple Packages Settings**
1923 +(% style="text-align:center" %)
1924 +[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1713 1713  
1926 +
1714 1714  (% style="text-align:center" %)
1715 -[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
1928 +[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1716 1716  
1717 -Check [Multiple packages supported] to open [Multiple package data] window, as below show.
1930 +**HMI Settings**
1718 1718  
1719 -Select Multiple package type
1932 +(% class="table-bordered" %)
1933 +|**Items**|**Settings**|**Note**
1934 +|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1935 +|Connection|RS485/RS232|
1936 +|Baud rate|2400~~187500|
1937 +|Data bit|8|
1938 +|Parity|Even/ Odd/ None|
1939 +|Stop bit|1/2|
1940 +|PLC station No.|0~~255|
1720 1720  
1721 -* Not Multiple packages
1722 -* J1939 Multiple packages
1723 -* Customized Multiple packages
1942 +**Address List**
1724 1724  
1725 -Click [Edit Receive data] for [Receive] settings
1944 +(% class="table-bordered" %)
1945 +|**Type**|**Address Type**|**Function code & Description**
1946 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1947 +|06 (write single register: write a binary value to a holding register)
1948 +|10 (write values to multiple addresses )
1949 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1950 +|06 (write single register: write a binary value to a holding register)
1951 +|10 (write values to multiple addresses )
1952 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1953 +|06 (write single register: write a binary value to a holding register)
1954 +|10 (write values to multiple addresses )
1955 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1956 +|10 (write values to multiple addresses )
1957 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1958 +|05 (Force a single coil to force the on/off state of a logic coil)
1959 +|0F (Write multiple bits, ie write continuously)
1960 +|(% rowspan="3" %)1|02 (Read the input state)
1961 +|05 (Force a single coil to force the on/off state of a logic coil)
1962 +|0F (Write multiple bits)
1963 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1964 +|05 (Force a single coil to force the on/off state of a logic coil)
1965 +|0F (Write multiple bits)
1966 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1967 +|0F (Write multiple bits)
1726 1726  
1727 -* Start code+ Total length (J1939)
1969 +**✎Note:**
1728 1728  
1729 -(% style="text-align:center" %)
1730 -[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1971 +* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1972 +* The function codes sent out are the same as those that read and write words.
1731 1731  
1732 -As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
1974 +**Station number for more than one slaves**
1733 1733  
1734 -* Start code + Data max length (J1939)
1976 +If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1735 1735  
1736 1736  (% style="text-align:center" %)
1737 -[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1979 +[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1738 1738  
1739 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
1981 +**Cable Wiring**
1740 1740  
1741 -* Data max length (J1939)
1983 +* **RS485**
1742 1742  
1743 1743  (% style="text-align:center" %)
1744 -[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1986 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1745 1745  
1746 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
1988 +(% style="text-align:center" %)
1989 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1747 1747  
1748 -* Customized multiple package
1991 +* **RS232**
1749 1749  
1750 1750  (% style="text-align:center" %)
1751 -[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
1994 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1752 1752  
1753 -As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
1996 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1754 1754  
1755 -Click [Edit Send data] for [Send] setting
1998 +== **MODBUS TCP Slave (All function)** ==
1756 1756  
1757 -* J1939
2000 +Supported series: MODBUS TCP controller
1758 1758  
2002 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
2003 +
1759 1759  (% style="text-align:center" %)
1760 -[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
2005 +[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1761 1761  
1762 -[Data] is all data to be sent.
2007 +(% style="text-align:center" %)
2008 +[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1763 1763  
1764 -Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
1765 1765  
1766 -* Customized multiple package
2011 +(% style="text-align:center" %)
2012 +[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1767 1767  
2014 +**HMI Setting**
2015 +
2016 +(% class="table-bordered" %)
2017 +|**Items**|**Settings**|**Note**
2018 +|Protocol|MODBUS TCP Slave (All function)|
2019 +|Connection|Ethernet|
2020 +|Port No.|502|
2021 +|PLC station No.|1|
2022 +
2023 +**Address List**
2024 +
2025 +(% class="table-bordered" %)
2026 +|**Type**|**Register**|**Function code & Description**
2027 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2028 +|06 (write single register: write a binary value to a holding register)
2029 +|10 (write values to multiple addresses )
2030 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2031 +|06 (write single register: write a binary value to a holding register)
2032 +|10 (write values to multiple addresses )
2033 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2034 +|06 (write single register: write a binary value to a holding register)
2035 +|10 (write values to multiple addresses )
2036 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2037 +|10 (write values to multiple addresses )
2038 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2039 +|05 (Force a single coil to force the on/off state of a logic coil)
2040 +|0F (Write multiple bits, ie write continuously)
2041 +|(% rowspan="3" %)1|02 (Read the input state)
2042 +|05 (Force a single coil to force the on/off state of a logic coil)
2043 +|0F (Write multiple bits)
2044 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2045 +|05 (Force a single coil to force the on/off state of a logic coil)
2046 +|0F (Write multiple bits)
2047 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2048 +|0F (Write multiple bits)
2049 +
2050 +**Communication Settings**
2051 +
2052 +Enable HMI Ethernet in [Project Settings];
2053 +
1768 1768  (% style="text-align:center" %)
1769 -[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
2055 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1770 1770  
1771 -[Data] is all data to be sent.
2057 +Set PLC IP in [Device IP] settings;
1772 1772  
1773 -As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
2059 +(% style="text-align:center" %)
2060 +[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1774 1774  
1775 1775  **Cable Wiring**
1776 1776  
1777 1777  (% style="text-align:center" %)
1778 -[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
2065 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1779 1779  
1780 -**✎Note:** The address interval between each frame need to be more than a word address;
1781 -
1782 1782  = **SHIMADEN** =
1783 1783  
1784 1784  == **FP23** ==
... ... @@ -1953,559 +1953,6 @@
1953 1953  
1954 1954  **✎Note:** COM3 only available in PI8000/PI9000 series.
1955 1955  
1956 -= **Siemens** =
1957 -
1958 -== **S7-200 Smart Ethernet** ==
1959 -
1960 -Supported Series: Siemens S7-200 SMART Series Ethernet Module.
1961 -
1962 -Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
1963 -
1964 -**HMI Setting**
1965 -
1966 -(% class="table-bordered" %)
1967 -|**Items**|**Settings**|**Note**
1968 -|Protocol|Simens S7-200 Smart Ethernet|
1969 -|Connection|Ethernet|
1970 -|Port No.|102|
1971 -|PLC station No.|2|
1972 -
1973 -**Address List**
1974 -
1975 -(% class="table-bordered" %)
1976 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1977 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1978 -|Q|Q|Q ddddd.o|0.0~~99999.7|
1979 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
1980 -|V|V|V ddddd.o|0.0~~99999.7|
1981 -|M|M|M ddddd.o|0.0~~99999.7|
1982 -|SM|SM|ddddd.o|0.0~~99999.7|
1983 -|S|S|ddddd.o|0.0~~99999.7|Read only
1984 -|T|T|ddddd|0~~99999|Timer state, read only
1985 -|C|C|ddddd|0~~99999|Counter state, read only
1986 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
1987 -|Q|QW|QW ddddd|0~~99999|
1988 -|AI|AIW|AIW ddddd|0~~99999|
1989 -|AQ|VB|VB ddddd|0~~99999|
1990 -|V|VW|VW ddddd|0~~99998|(((
1991 -VW0=VB (0~~1)
1992 -
1993 -VW2=VB (2~~3)
1994 -
1995 -Address value is a multiple of 2
1996 -)))
1997 -|V|VD|VD ddddd|0~~99998|(((
1998 -VD0=VB (0~~3)
1999 -
2000 -VD2=VB (4~~7)
2001 -
2002 -Address value is a multiple of 4
2003 -)))
2004 -|M|MB|MB ddddd|0~~99999|
2005 -|M|MW|MW ddddd|0~~99999|(((
2006 -MW0=MB(0~~1)
2007 -
2008 -MW2=MB(2~~3)
2009 -
2010 -Address value is a multiple of 2
2011 -)))
2012 -|M|MD|MD ddddd|0~~99999|(((
2013 -MD0=MB(0~~3)
2014 -
2015 -MD4=MB(4~~7)
2016 -
2017 -Address value is a multiple of 4
2018 -)))
2019 -|T|TW|TW ddddd|0~~99999|Value of timer
2020 -|C|CW|CW ddddd|0~~99999|Value of counter
2021 -|W|SW|SW ddddd|0~~99999|
2022 -
2023 -**Communication Settings**
2024 -
2025 -Enable HMI Ethernet in [Project Settings];
2026 -
2027 -(% style="text-align:center" %)
2028 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2029 -
2030 -Set PLC IP in [Device IP] settings;
2031 -
2032 -(% style="text-align:center" %)
2033 -[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2034 -
2035 -* PLC IP Address: PLC IP
2036 -* PLC pot No.: 102(fixed)
2037 -* Network:TCP_Client_2N(fixed)
2038 -
2039 -(% style="text-align:center" %)
2040 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
2041 -
2042 -* Wait timeout: depend on actual network situation (more than 1500 ms)
2043 -
2044 -**Cable Wiring**
2045 -
2046 -(% style="text-align:center" %)
2047 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2048 -
2049 -== **S7-300 Ethernet** ==
2050 -
2051 -Supported Series: Siemens S7-300 series PLC
2052 -
2053 -**HMI Setting**
2054 -
2055 -(% class="table-bordered" %)
2056 -|**Items**|**Settings**|**Note**
2057 -|Protocol|Simens S7-300 Ethernet|
2058 -|Connection|Ethernet|
2059 -|Port No.|102|
2060 -|PLC station No.|2|Need to be same as the PLC setting
2061 -
2062 -**Address List**
2063 -
2064 -(% class="table-bordered" %)
2065 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2066 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
2067 -|Q|Q|Q ddddd.o|0.0~~99999.7|
2068 -|M|M|M ddddd.o|0.0~~99999.7|
2069 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
2070 -nn: block number;
2071 -
2072 -dddd: address;
2073 -)))
2074 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
2075 -|Q|QW|QW ddddd|0~~99999|
2076 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
2077 -|MW|MW ddddd|0~~99999|(((
2078 -MW0=MB(0~~1)
2079 -
2080 -MW2=MB(2~~3)
2081 -
2082 -Address value is a multiple of 2
2083 -)))
2084 -|MD|MD ddddd|0~~99999|(((
2085 -MD0=MB(0~~3)
2086 -
2087 -MD4=MB(4~~7)
2088 -
2089 -Address value is a multiple of 4
2090 -)))
2091 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
2092 -nn: block number;
2093 -
2094 -dddd: address
2095 -)))
2096 -|DBxDBW|DBxDBW nndddd|0~~99999999
2097 -|DBxDBD|DBxDBD nndddd|0~~99999999
2098 -
2099 -**Communication Settings**
2100 -
2101 -Enable HMI Ethernet in [Project Settings];
2102 -
2103 -(% style="text-align:center" %)
2104 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2105 -
2106 -Set PLC IP in [Device IP] settings;
2107 -
2108 -(% style="text-align:center" %)
2109 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
2110 -
2111 -* PLC IP Address: PLC IP
2112 -* PLC pot No.: 102(fixed)
2113 -* Network:TCP_Client_2N(fixed)
2114 -
2115 -(% style="text-align:center" %)
2116 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
2117 -
2118 -* Wait timeout: depend on actual network situation (more than 1500 ms)
2119 -
2120 -**Cable Wiring**
2121 -
2122 -(% style="text-align:center" %)
2123 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2124 -
2125 -== **S7-1200 Ethernet** ==
2126 -
2127 -Supported Series: Siemens S7-1200
2128 -
2129 -**HMI Setting**
2130 -
2131 -(% class="table-bordered" %)
2132 -|**Items**|**Settings**|**Note**
2133 -|Protocol|Siemens S7-1200|
2134 -|Connection|Ethernet|
2135 -|Port No.|102|
2136 -|PLC station No.|2|
2137 -
2138 -**Address List**
2139 -
2140 -(% class="table-bordered" %)
2141 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2142 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
2143 -d:0~-~-9999
2144 -
2145 -o:0-7
2146 -)))|
2147 -|Q|Q|Q d.o|(((
2148 -d:0~-~-9999
2149 -
2150 -o:0-7
2151 -)))|
2152 -|M|M|M d.o|(((
2153 -d:0~-~-9999
2154 -
2155 -o:0-7
2156 -)))|
2157 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2158 -nn:0-9999,
2159 -
2160 -dddd:0-9999,
2161 -
2162 -o:0-7
2163 -)))|(((
2164 -nn:DB No.
2165 -
2166 -dddd:address value
2167 -
2168 -o: digit address
2169 -)))
2170 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2171 -|M|MW|MW d|d:0-99999|(((
2172 -MW0=MB(0~~1)
2173 -
2174 -MW2=MB(2~~3)
2175 -
2176 -Address value is a multiple of 2
2177 -)))
2178 -|M|MD|MD d|d:0-99999|(((
2179 -MD0=MB(0~~3)
2180 -
2181 -MD4=MB(4~~7)
2182 -
2183 -Address value is a multiple of 4
2184 -)))
2185 -|I|IW|IW d|d:0-99999|
2186 -|Q|QW|QW d|d:0-99999|
2187 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2188 -nn:0-9999
2189 -
2190 -dddd:0-9999
2191 -)))|(((
2192 -nn:DB No.
2193 -
2194 -dddd:address value
2195 -)))
2196 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2197 -nn:0-9999
2198 -
2199 -dddd:0-9999
2200 -)))|(((
2201 -nn:DB No.
2202 -
2203 -dddd:address value
2204 -
2205 -Address value is a multiple of 2
2206 -)))
2207 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2208 -nn:0-9999
2209 -
2210 -dddd:0-9999
2211 -)))|(((
2212 -nn:DB No.
2213 -
2214 -dddd:address value
2215 -
2216 -Address value is a multiple of 4
2217 -)))
2218 -
2219 -**Communication Settings**
2220 -
2221 -Enable HMI Ethernet in [Project Settings];
2222 -
2223 -(% style="text-align:center" %)
2224 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2225 -
2226 -Set PLC IP in [Device IP] settings;
2227 -
2228 -(% style="text-align:center" %)
2229 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2230 -
2231 -**✎Note:**
2232 -
2233 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2234 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2235 -
2236 -**PLC Settings**
2237 -
2238 -Add BD
2239 -
2240 -* Please uncheck [Symbolic access only] option;
2241 -
2242 -(% style="text-align:center" %)
2243 -[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
2244 -
2245 -Address settings, using BD2 as example.
2246 -
2247 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
2248 -* 2 represent DB block number
2249 -* xxxx represent address
2250 -
2251 -**Such as:**
2252 -
2253 -* DBxDBB20000 = DB2.DBB0
2254 -* DBxDBW20004 = DB2.DBW4
2255 -
2256 -(% style="text-align:center" %)
2257 -[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
2258 -
2259 -**How to connect with S7-1200 Firmware V4.0**
2260 -
2261 -PLC configuration
2262 -
2263 -* Double click [device configuration] in Siemens via software
2264 -* Double click [protection] to enter protection configuration screen
2265 -
2266 -(% style="text-align:center" %)
2267 -[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
2268 -
2269 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
2270 -
2271 -(% style="text-align:center" %)
2272 -[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
2273 -
2274 -DB settings
2275 -
2276 -* Right click [DB], select [properties]
2277 -* Uncheck [optimized block access]
2278 -
2279 -**Cable Wiring**
2280 -
2281 -(% style="text-align:center" %)
2282 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2283 -
2284 -== **LOGO Ethernet** ==
2285 -
2286 -Supported Series: Siemens Logo 0BA0 series
2287 -
2288 -**HMI Settings**
2289 -
2290 -(% class="table-bordered" %)
2291 -|**Items**|**Settings**|**Note**
2292 -|Protocol|Siemens LOGO|
2293 -|Connection|Ethernet|
2294 -|Port No.|102|
2295 -|PLC station No.|2|
2296 -
2297 -**Address List**
2298 -
2299 -(% class="table-bordered" %)
2300 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
2301 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
2302 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
2303 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
2304 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
2305 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
2306 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
2307 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
2308 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
2309 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
2310 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
2311 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
2312 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
2313 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
2314 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
2315 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
2316 -
2317 -**PLC Settings in LOGO Software:**
2318 -
2319 -Click [Tools]~-~-[Ethernet Connections],shown as below.
2320 -
2321 -(% style="text-align:center" %)
2322 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
2323 -
2324 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
2325 -
2326 -(% style="text-align:center" %)
2327 -[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
2328 -
2329 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
2330 -
2331 -(% style="text-align:center" %)
2332 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
2333 -
2334 -**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
2335 -
2336 -(% style="text-align:center" %)
2337 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
2338 -
2339 -
2340 -(% style="text-align:center" %)
2341 -[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
2342 -
2343 -
2344 -**HMI Communication Settings**
2345 -
2346 -Set PLC IP in [Device IP] settings;
2347 -
2348 -(% style="text-align:center" %)
2349 -[[image:SiemensLOGODeviceIP.png]]
2350 -
2351 -Enable HMI Ethernet in [Project Settings];
2352 -
2353 -(% style="text-align:center" %)
2354 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
2355 -
2356 -TSAP setting
2357 -
2358 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
2359 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
2360 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
2361 -
2362 -**✎Note:**
2363 -
2364 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
2365 -
2366 -(% style="text-align:center" %)
2367 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
2368 -
2369 -
2370 -* AI word address and Ibit address are read-only and cannot be written on HMI.
2371 -* VW address should be even number.such as VW0, VW2, VW4...
2372 -* VD address it takes two VW addresses.such as VD0,VD4,VD8...
2373 -* Written value of RTC cannot exceed 255.
2374 -
2375 -**Cable Wiring**
2376 -
2377 -(% style="text-align:center" %)
2378 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2379 -
2380 -== **S7-XXX Ethernet** ==
2381 -
2382 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
2383 -
2384 -**HMI Setting**
2385 -
2386 -(% class="table-bordered" style="width:823px" %)
2387 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2388 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2389 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2390 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2391 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2392 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2393 -
2394 -Slot from TIA Portal is equal to Device No. of PIStudio
2395 -
2396 -Rack from TIA Portal is equal to HMI No. of PIStudio
2397 -
2398 -(% style="text-align:center" %)
2399 -[[image:S7-XXXCommunication Settings.png]]
2400 -
2401 -(% style="text-align:center" %)
2402 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2403 -
2404 -**Address List**
2405 -
2406 -(% class="table-bordered" %)
2407 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2408 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
2409 -d:0~-~-9999
2410 -
2411 -o:0-7
2412 -)))|
2413 -|Q|Q|Q d.o|(((
2414 -d:0~-~-9999
2415 -
2416 -o:0-7
2417 -)))|
2418 -|M|M|M d.o|(((
2419 -d:0~-~-9999
2420 -
2421 -o:0-7
2422 -)))|
2423 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2424 -nn:0-9999,
2425 -
2426 -dddd:0-9999,
2427 -
2428 -o:0-7
2429 -)))|(((
2430 -nn:DB No.
2431 -
2432 -dddd:address value
2433 -
2434 -o: digit address
2435 -)))
2436 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2437 -|M|MW|MW d|d:0-99999|(((
2438 -MW0=MB(0~~1)
2439 -
2440 -MW2=MB(2~~3)
2441 -
2442 -Address value is a multiple of 2
2443 -)))
2444 -|M|MD|MD d|d:0-99999|(((
2445 -MD0=MB(0~~3)
2446 -
2447 -MD4=MB(4~~7)
2448 -
2449 -Address value is a multiple of 4
2450 -)))
2451 -|I|IW|IW d|d:0-99999|
2452 -|Q|QW|QW d|d:0-99999|
2453 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2454 -nn:0-9999
2455 -
2456 -dddd:0-9999
2457 -)))|(((
2458 -nn:DB No.
2459 -
2460 -dddd:address value
2461 -)))
2462 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2463 -nn:0-9999
2464 -
2465 -dddd:0-9999
2466 -)))|(((
2467 -nn:DB No.
2468 -
2469 -dddd:address value
2470 -
2471 -Address value is a multiple of 2
2472 -)))
2473 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2474 -nn:0-9999
2475 -
2476 -dddd:0-9999
2477 -)))|(((
2478 -nn:DB No.
2479 -
2480 -dddd:address value
2481 -
2482 -Address value is a multiple of 4
2483 -)))
2484 -
2485 -**Communication Settings**
2486 -
2487 -Enable HMI Ethernet in [Project Settings];
2488 -
2489 -(% style="text-align:center" %)
2490 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
2491 -
2492 -Set PLC IP in [Device IP] settings;
2493 -
2494 -(% style="text-align:center" %)
2495 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2496 -
2497 -**✎Note:**
2498 -
2499 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2500 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2501 -
2502 -**Cable Wiring**
2503 -
2504 -{{id name="OLE_LINK8"/}}
2505 -
2506 -(% style="text-align:center" %)
2507 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2508 -
2509 2509  = **User Defined Protocol** =
2510 2510  
2511 2511  If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.
... ... @@ -2650,8 +2650,6 @@
2650 2650  
2651 2651  **✎Note:** COM3 only available in PI8000/PI9000 series.
2652 2652  
2653 -= =
2654 -
2655 2655  = **Printer** =
2656 2656  
2657 2657  == **TSPL label printer** ==
... ... @@ -2852,3 +2852,449 @@
2852 2852  
2853 2853  (% style="text-align:center" %)
2854 2854  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2585 +
2586 += **Barcode Scanner** =
2587 +
2588 +Supported: DELI 14880 barcode scanner
2589 +
2590 +**HMI Setting**
2591 +
2592 +|**Items**|**Settings**|**Note**
2593 +|Protocol|Barcode Scanner|
2594 +|Connection|USB|
2595 +
2596 +**Operating Procedures**
2597 +
2598 +Select [Barcode Scanner];
2599 +
2600 +(% style="text-align:center" %)
2601 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2602 +
2603 +Set address for receiving;
2604 +
2605 +Set correct length;
2606 +
2607 +(% style="text-align:center" %)
2608 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2609 +
2610 +**✎Note:**
2611 +
2612 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2613 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2614 +* Recommended model: DELI 14880 barcode scanner;
2615 +
2616 += **Hitachi EHV Series (Ethernet)** =
2617 +
2618 +Supported series: Hitachi EHV series
2619 +
2620 +**HMI Settings**
2621 +
2622 +(% class="table-bordered" %)
2623 +|**Items**|**Settings**|**Note**
2624 +|Protocol|Hitachi EHV series|
2625 +|Connection|Ethernet|
2626 +|Port No.|3004~~3007|
2627 +
2628 +**Address List**
2629 +
2630 +(% class="table-bordered" %)
2631 +|**Type**|**Register**|**Range**|**Format**|**Note**
2632 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2633 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2634 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2635 +H1H2H3H4 Module main number
2636 +
2637 +H1: Remote number
2638 +
2639 +H2: Unit number
2640 +
2641 +H3: Slot number
2642 +
2643 +H4: Word number of Module
2644 +
2645 +H Sub number of Module
2646 +
2647 +For example:X21.3
2648 +
2649 +Slot number 2
2650 +
2651 +Word number of module is 1
2652 +
2653 +Bit number of module is 3
2654 +
2655 +Remote number and unit number are 0
2656 +)))
2657 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2658 +|R|0 – FF.f (Hex)|R HH.h|
2659 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2660 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2661 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2662 +H1H2H3H4 Module main number
2663 +
2664 +H1: Remote number
2665 +
2666 +H2: Unit number
2667 +
2668 +H3: Slot number
2669 +
2670 +H4: Word number of module
2671 +
2672 +For example:WX21
2673 +
2674 +Word number of module is 1
2675 +
2676 +Slot number is 2
2677 +
2678 +Remote number and unit number are 0
2679 +)))
2680 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2681 +|WR|0 – FFFF (Hex)|WR HHHH|
2682 +|WL|0 - 73FF (Hex)|WL HHHH|
2683 +|TC|0 - 2559|TC DDDD|
2684 +
2685 +**Communication settings in HMI**
2686 +
2687 +Enable HMI Ethernet in [Project Settings];
2688 +
2689 +(% style="text-align:center" %)
2690 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2691 +
2692 +Set PLC IP in [Device IP] settings;
2693 +
2694 +(% style="text-align:center" %)
2695 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2696 +
2697 +**PLC Configuration**
2698 +
2699 +Connect with PLC, select[Online mode];
2700 +
2701 +(% style="text-align:center" %)
2702 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2703 +
2704 +Set IP address, it is the same LAN parameters with HMI;
2705 +
2706 +(% style="text-align:center" %)
2707 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2708 +
2709 +3) Save PLC communication parameter, and restart PLC
2710 +
2711 +**PLC Monitor Mode**
2712 +
2713 +Connect with PLC and choose to “online” mode
2714 +
2715 +(% style="text-align:center" %)
2716 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2717 +
2718 +Open I/O monitor sheet1
2719 +
2720 +(% style="text-align:center" %)
2721 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2722 +
2723 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2724 +
2725 +(% style="text-align:center" %)
2726 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2727 +
2728 +Enter the register address, click OK to view the value of the register.
2729 +
2730 +(% style="text-align:center" %)
2731 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2732 +
2733 +(% style="text-align:center" %)
2734 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2735 +
2736 +**✎Note:**
2737 +
2738 +* Both word registers and bit registers support even continuous read/write functions;
2739 +* The range of registers is based on the specific PLC type;
2740 +
2741 +**Cable Wiring**
2742 +
2743 +(% style="text-align:center" %)
2744 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2745 +
2746 += **IEC60870-5 104 Client** =
2747 +
2748 +**HMI Setting**
2749 +
2750 +(% class="table-bordered" %)
2751 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2752 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2753 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2754 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2755 +
2756 +**Address List**
2757 +
2758 +(% class="table-bordered" %)
2759 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2760 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2761 +|(% style="width:461px" %)SCNA|0~~16777215.7
2762 +|(% style="width:461px" %)DPTB|0~~16777215.7
2763 +|(% style="width:461px" %)DCNA|0~~16777215.7
2764 +|(% style="width:461px" %)METF|0~~16777215.7
2765 +|(% style="width:461px" %)SENC|0~~16777215.7
2766 +|(% style="width:461px" %)SENA|0~~16777215.7
2767 +|(% style="width:461px" %)MENA|0~~16777215.7
2768 +|(% style="width:461px" %)METD|0~~16777215.7
2769 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2770 +|(% style="width:461px" %)SCNA|0~~16777215
2771 +|(% style="width:461px" %)DPTB|0~~16777215
2772 +|(% style="width:461px" %)DCNA|0~~16777215
2773 +|(% style="width:461px" %)SENA|0~~16777215
2774 +|(% style="width:461px" %)MENA|0~~16777215
2775 +|(% style="width:461px" %)METD|0~~16777215
2776 +|(% style="width:461px" %)INRO|0~~16777215
2777 +|(% style="width:461px" %)TIMESYN|0~~16777215
2778 +|(% style="width:461px" %)TIMEZ|0~~16777215
2779 +|(% style="width:461px" %)NTP|0~~16777215
2780 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2781 +|(% style="width:461px" %)SENC|0~~16777215
2782 +
2783 +**Address Configuration**
2784 +
2785 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2786 +
2787 +(% style="text-align:center" %)
2788 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2789 +
2790 +(% style="text-align:center" %)
2791 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2792 +
2793 +Extended tag name
2794 +
2795 +Address range for the extended tag.
2796 +
2797 +**Communication Settings**
2798 +
2799 +Enable HMI Ethernet in [Project Settings];
2800 +
2801 +(% style="text-align:center" %)
2802 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2803 +
2804 +Set PLC IP in [Device IP] settings;
2805 +
2806 +(% style="text-align:center" %)
2807 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2808 +
2809 +**Cable Wiring**
2810 +
2811 +(% style="text-align:center" %)
2812 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2813 +
2814 += **LG XGK FEnet Ethernet** =
2815 +
2816 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2817 +
2818 +**HMI Settings**
2819 +
2820 +(% class="table-bordered" %)
2821 +|**Items**|**Settings**|**Note**
2822 +|Protocol|LG XGK FEnet(Ethernet)|
2823 +|Connection|Ethernet|
2824 +|Port No.|2004|
2825 +
2826 +**Address List**
2827 +
2828 +(% class="table-bordered" %)
2829 +|**Type**|**Register**|**Range**|**Format**|**Note**
2830 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2831 +|M|0~~2047|M d|
2832 +|K|0~~2047|K d|
2833 +|F|0~~2047|F d|
2834 +|T|0~~2047|T d|
2835 +|C|0~~2047|C d|
2836 +|Z|0~~127|Z d|
2837 +|S|0~~127|S d|
2838 +|L|0~~11263|L d|
2839 +|N|0~~21503|N d|
2840 +|D|0~~32767|D d|
2841 +|R|0~~32767|R d|
2842 +|ZR|0~~65535|ZR d|
2843 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2844 +
2845 +**✎Note:**
2846 +
2847 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2848 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2849 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2850 +
2851 +**Communication settings in HMI**
2852 +
2853 +Enable HMI Ethernet in [Project Settings];
2854 +
2855 +(% style="text-align:center" %)
2856 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2857 +
2858 +Set PLC IP in [Device IP] settings;
2859 +
2860 +(% style="text-align:center" %)
2861 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2862 +
2863 +**Cable Wiring**
2864 +
2865 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2866 +
2867 +
2868 += **OpenCAN** =
2869 +
2870 +OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
2871 +
2872 +This protocol is only available in PI8000 series HMI.
2873 +
2874 +**HMI Settings**
2875 +
2876 +|**Items**|**Settings**|**Note**
2877 +|Protocol|OPENCAN|
2878 +|Connection|CAN port|
2879 +|Baud rate|250000|
2880 +
2881 +**CAN frame setting in HMI**
2882 +
2883 +Click [OpenCAN setting] button in communication setting window;
2884 +
2885 +(% style="text-align:center" %)
2886 +[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
2887 +
2888 +Click [Add] to create a new frame;
2889 +
2890 +(% style="text-align:center" %)
2891 +[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
2892 +
2893 +|**No**|**Items**|**Description**
2894 +|1|Add|add a frame related to register address
2895 +|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
2896 +|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
2897 +|4|Modify|Modify the frames in frame management
2898 +|5|Copy|Copy one frame to another
2899 +|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
2900 +|7|Empty|All frames in the list are cleared
2901 +|8|Browse|Displays configuration files in XML format in IE
2902 +|9|OK|Complete the configuration of the frame and exit
2903 +
2904 +Set CANBUS frame in setting windows
2905 +
2906 +(% style="text-align:center" %)
2907 +[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
2908 +
2909 +|**No**|**Items**|**Description**
2910 +|1|ID|Set the ID of a can frame in hexadecimal format;
2911 +|2|ID assign|split the ID by PF, PS, and SA;
2912 +|3|Frame type|Select Standard frame or Extended Frame;
2913 +|4|Frame format|Select between data frame and remote Frame;
2914 +|5|Data|Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
2915 +|6|Use address|(((
2916 +Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
2917 +
2918 +**Edit:** Set a bit or word address by its format;
2919 +
2920 +**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
2921 +)))
2922 +|(% rowspan="8" %)7|(% rowspan="8" %)Data interactive configuration|There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
2923 +|Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
2924 +|Feedback mode: feedback mode includes no response, confirm response and data response;
2925 +|No response: the device or touch screen will not receive feedback;
2926 +|Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
2927 +|Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
2928 +|response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
2929 +|Response timeout: sets whether the response frame timeout;
2930 +|(% rowspan="3" %)8|(% rowspan="3" %)Control address|If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
2931 +|Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
2932 +|Manually send: a manually send tick indicates only one send;
2933 +|9|Flag configuration|Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
2934 +|10|Note|Fill the text to explain the meaning of the frame;
2935 +|11|Data assign|Preview the display in this table based on the address and the corresponding number of digits;
2936 +|12|Current operation display|Display the description of current operation;
2937 +|13|Add|Add a new frame;
2938 +|14|Save frame|Save the configured frame format;
2939 +|15|Cancel|Cancel the frame configuration;
2940 +
2941 +Set CAN address (Read or write operation);
2942 +
2943 +(% style="text-align:center" %)
2944 +[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
2945 +
2946 +|**No.**|**Item**|**Description**
2947 +|1|Current address|Displays the register type and register address set by the user in the data access interface
2948 +|(% rowspan="3" %)2|(% rowspan="3" %)Trigger|Two operations, "read" and "write," are based on on-screen registers
2949 +|If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
2950 +|If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
2951 +|(% rowspan="5" %)3|(% rowspan="3" %)Data operation|The read and write operations in the trigger conditions are set accordingly.
2952 +|If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
2953 +|If the trigger condition is a writing operation, there are two situations:(((
2954 +* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
2955 +* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
2956 +)))
2957 +|(% rowspan="2" %)Position and length input format|If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
2958 +|If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
2959 +|4|Add|Add current configuration
2960 +|5|Close|Close the configuration window to exit
2961 +
2962 +**Multiple Packages Settings**
2963 +
2964 +(% style="text-align:center" %)
2965 +[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
2966 +
2967 +Check [Multiple packages supported] to open [Multiple package data] window, as below show.
2968 +
2969 +Select Multiple package type
2970 +
2971 +* Not Multiple packages
2972 +* J1939 Multiple packages
2973 +* Customized Multiple packages
2974 +
2975 +Click [Edit Receive data] for [Receive] settings
2976 +
2977 +* Start code+ Total length (J1939)
2978 +
2979 +(% style="text-align:center" %)
2980 +[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2981 +
2982 +As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
2983 +
2984 +* Start code + Data max length (J1939)
2985 +
2986 +(% style="text-align:center" %)
2987 +[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2988 +
2989 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
2990 +
2991 +* Data max length (J1939)
2992 +
2993 +(% style="text-align:center" %)
2994 +[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2995 +
2996 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
2997 +
2998 +* Customized multiple package
2999 +
3000 +(% style="text-align:center" %)
3001 +[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
3002 +
3003 +As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
3004 +
3005 +Click [Edit Send data] for [Send] setting
3006 +
3007 +* J1939
3008 +
3009 +(% style="text-align:center" %)
3010 +[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
3011 +
3012 +[Data] is all data to be sent.
3013 +
3014 +Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
3015 +
3016 +* Customized multiple package
3017 +
3018 +(% style="text-align:center" %)
3019 +[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
3020 +
3021 +[Data] is all data to be sent.
3022 +
3023 +As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
3024 +
3025 +**Cable Wiring**
3026 +
3027 +(% style="text-align:center" %)
3028 +[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
3029 +
3030 +**✎Note:** The address interval between each frame need to be more than a word address;
image-20220829151746-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.1 KB
Content
image-20220829151848-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +15.0 KB
Content
image-20220829152016-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.2 KB
Content
image-20220829152042-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +17.0 KB
Content
image-20220829152102-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +16.3 KB
Content
image-20220829152327-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.5 KB
Content
image-20220829152610-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +55.5 KB
Content
image-20220829155452-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.1 KB
Content
image-20220829162116-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.4 KB
Content
image-20220830094600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +40.4 KB
Content
image-20220830094657-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.4 KB
Content
image-20220830094929-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.4 KB
Content
image-20220830095131-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +25.7 KB
Content
image-20220830140537-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +35.2 KB
Content
image-20220830140629-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content
image-20220830141138-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +82.9 KB
Content