Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 65.1
edited by Ben
on 2022/08/29 14:05
Change comment: There is no comment for this version
To version 27.1
edited by Stone Wu
on 2022/08/17 15:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Stone
Content
... ... @@ -85,393 +85,6 @@
85 85  
86 86  Click [OK] button to save settings and close the dialog;
87 87  
88 -= Create communication with WECON PLC =
89 -
90 -
91 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 -
93 -**HMI Settings**
94 -
95 -(% class="table-bordered" %)
96 -|**Item**|**Settings**|**Note**
97 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
98 -|Connection|RS422/RS485|
99 -|Baud rate|9600|
100 -|Data bit|7|
101 -|Parity|EVEN|
102 -|Stop bit|1|
103 -|PLC station No.|1|
104 -
105 -**Address List**
106 -
107 -(% class="table-bordered" %)
108 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
109 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
110 -|Y|Y|Y o|0~~303237|
111 -|M|M|M d|0~~99999|
112 -|T|T|T d|0~~99999|
113 -|C|C|C d|0~~99999|
114 -|S|S|S d|0~~99999|
115 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
116 -|Y|Y|Y o|0~~303237|
117 -|M|M|M d|0~~99999|
118 -|T|T|T d|0~~99999|
119 -|C|C|C d|0~~199|
120 -|D|D|D d|0~~7999|
121 -|S|S|S d|0~~99999|
122 -|SD|SD|SD d|8000~~9999|
123 -
124 -**Cable Wiring**
125 -
126 -* **RS485**
127 -
128 -(% style="text-align:center" %)
129 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
130 -
131 -* **RS422**
132 -
133 -(% style="text-align:center" %)
134 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
135 -
136 -**✎Note:**
137 -
138 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
139 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
140 -
141 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 -
143 -== HMI settings ==
144 -
145 -**Download PIStudio Software**
146 -
147 -Please visit the link below to get the latest version PIstudio for HMI programming:
148 -
149 -* [[Download link>>doc:PIStudio.Download.3 Software.WebHome]]
150 -
151 -**Create a new HMI project connect with PLC**
152 -
153 -Check the link below for the video to show you how to get started with a new project
154 -
155 -* [[Video>>https://youtu.be/0FpmDZe_8U8]]
156 -
157 -For more videos, please visit our Youtube channel: [[http:~~/~~/www.youtube.com/user/Wecon2004/videos>>url:http://www.youtube.com/user/Wecon2004/videos]]
158 -
159 -**General**
160 -
161 -HMI could communicate with PLC and support many PLC protocols.  It is easy to operate and set communication parameters. This demo shows how to make a communication with PLC device, use WECON LX3V Series PLC as an example.
162 -
163 -**Protocol settings**
164 -
165 -The communication between two devices requires a protocol. The following contents show the steps of protocol settings.
166 -
167 -Please select the protocol, when creating a new project.
168 -
169 -1. Select the COM port for communication;
170 -1. PLC type: It means PLC brand, like WECON;
171 -1. PLC model: It shows the model of PLC, such as LX3V;
172 -
173 -(% style="text-align:center" %)
174 -[[image:image-20220819093729-1.png]]
175 -
176 -If you want to change the protocol for existing project, please click [Program] → [Communication] to open the [Communication] windows, shown as the following figure.
177 -
178 -(% style="text-align:center" %)
179 -[[image:image-20220819093729-2.png]]
180 -
181 -
182 -The steps to change the protocol for project are as follows.
183 -
184 -1. Click [Setting] to open the [Communication device] window;
185 -1. Select communication port, such as COM1;
186 -1. Select Serial port for communication, such as RS422;
187 -1. Select device type (device brand), such as WECON;
188 -1. Select the protocol for communication, such as WECON LX3V;
189 -
190 -(% style="text-align:center" %)
191 -[[image:image-20220819093729-3.png]]
192 -
193 -**Parameter settings**
194 -
195 -The parameters settings are in [Communication] window, shown as following below.
196 -
197 -1. Click [Setting] to open the [COM port setting] window;
198 -1. Set the parameters such as [connection], [Baud rate] and so on;
199 -
200 -(% style="text-align:center" %)
201 -[[image:image-20220819093729-4.png||height="636" width="818"]]
202 -
203 -(% start="3" %)
204 -1. Click [Setting] to open [Timeout] setting window, you could set the parameters according your requirements, or just use the default value.
205 -
206 -(% style="text-align:center" %)
207 -[[image:image-20220819093729-5.png]]
208 -
209 -**Set PLC address in HMI screen**
210 -
211 -1. Place the objects to HMI screen;
212 -1. Double-click the object to open the setting window;
213 -1. Click “Edit” to open the address setting windows;
214 -1. Connection: select the serial port in HMI;
215 -1. Address type: All the PLC address types will be display in this list, such as M;
216 -1. Address No.: Please input the number of this address, such as 0;
217 -
218 -[[image:image-20220819093729-6.jpeg]]
219 -
220 -**Communication cable**
221 -
222 -In order to ensure the stability of communication, please use the twisted-pair communication cable with good grounding. The following figure shows the pin out definition.
223 -
224 -(% style="text-align:center" %)
225 -[[image:image-20220819093729-7.png]]
226 -
227 -**HMI communication PLC use Modbus **
228 -
229 -* HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 -* PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 -
232 -== PLC settings ==
233 -
234 -**Download PLC Software**
235 -
236 -Please visit below link to get the latest version PLC Editor for HMI programming
237 -
238 -* LX3V:[[Download link>>doc:PLC Editor.10 Hardware .Software.WebHome]]
239 -* LX5V:[[Download link>>doc:PLC Editor2.Download.03 Software.WebHome]]
240 -
241 -**Start a new PLC project**
242 -
243 -Start a new PLC project by clicking “New” on the left top corner of screen, select the PLC mode from the drop-down list.
244 -
245 -(% style="text-align:center" %)
246 -[[image:image-20220819101447-3.jpeg]]
247 -
248 -
249 -
250 -**Add a new instruction **
251 -
252 -Double click on the ladder, select the ladder symbol (instruction) from the drop-down list, then enter the address for this symbol.
253 -
254 -(% style="text-align:center" %)
255 -[[image:image-20220819105530-1.png]]
256 -
257 -You could also select the ladder symbol from the menu bar directly.
258 -
259 -[[image:image-20220819093729-11.png]]
260 -
261 -[[image:image-20220819093729-12.png]]
262 -
263 -**Add comment to PLC program**
264 -
265 -(% style="text-align:center" %)
266 -[[image:image-20220819105630-3.png]]
267 -
268 -**Add the statement to PLC program**
269 -
270 -Add the statement by single click on “Statement”, when finished, single click on “Statement” again to go back to Ladder edit.
271 -
272 -(% style="text-align:center" %)
273 -[[image:image-20220819105644-4.png]]
274 -
275 -**Compile **
276 -
277 -You need to compile the PLC program before downloading or running Off-line simulator. The background color will be changed from purple to white when there is no error.
278 -
279 -[[image:image-20220819093729-15.png]]
280 -
281 -**Download setting **
282 -
283 -Click on “Transfer Setup” to select download mode.
284 -
285 -[[image:image-20220820150853-1.png]]**Download PLC program to PLC**
286 -
287 -Quick select the parameters and main program of PLC program, then download to PLC, “Yes”-”Yes”-”OK”
288 -
289 -[[image:image-20220819093729-17.png]]
290 -
291 -**Upload PLC program from PLC**
292 -
293 -Read the PLC program from PLC to computer.
294 -
295 -[[image:image-20220819093729-18.png]]
296 -
297 -**Device monitor**
298 -
299 -Monitor the value of certain address in PLC, double click “Current value” to change the value in this address.
300 -
301 -[[image:image-20220819093730-19.png]]
302 -
303 -**Online monitor**
304 -
305 -Monitor the each address in PLC by online monitor. Changing the state or value in PLC is also allowd.
306 -
307 -[[image:image-20220819093730-20.png]]
308 -
309 -**Monitor edit**
310 -
311 -In this mode, you could edit the PLC program during PLC is running. 
312 -
313 -
314 -(% style="text-align:center" %)
315 -[[image:image-20220819105928-9.png||height="229" width="669"]]
316 -
317 -= **WECON PLC** =
318 -
319 -
320 -
321 -== **HMI and Wecon LX5V serial communication** ==
322 -
323 -This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
324 -
325 -**Software configuration of PLC**
326 -
327 -**1)PLC programming software**
328 -
329 -[[image:image-20220810164710-1.png]]
330 -
331 -**2)New PLC project**
332 -
333 -Click New Project and select the PLC model.
334 -
335 -[[image:image-20220810172412-1.png]]
336 -
337 -
338 -**3)Set Serial port parameters**
339 -
340 -Follow the steps below to configure Serial port parameters
341 -
342 -Baud rate:115200
343 -
344 -Data bit:8
345 -
346 -Stop bit:1
347 -
348 -Parity:No verification
349 -
350 -[[image:image-20220810165759-3.png]]
351 -
352 -
353 -**4)Registers list**
354 -
355 -[[image:image-20220811102219-3.png]]
356 -
357 -
358 -**HMI software configuration**
359 -
360 -**1)HMI programming software**
361 -
362 - [[image:image-20220810171237-4.png]]
363 -
364 -**2)New HMI project**
365 -
366 -Click New Project and select the HMI model.
367 -
368 -[[image:image-20220810172010-5.png]]
369 -
370 -**3)Set communication port parameters**
371 -
372 -Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
373 -
374 -Baud rate:115200
375 -
376 -Data bit:8
377 -
378 -Stop bit:1
379 -
380 -Parity:No verification
381 -
382 -
383 -[[image:image-20220811104012-1.png]]
384 -
385 -
386 -**hardware connection**
387 -
388 -**1)Hardware wiring diagram**
389 -
390 -This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
391 -
392 -[[image:image-20220811103005-4.png]]
393 -
394 -
395 -[[image:image-20220811103227-7.png]]
396 -
397 -The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
398 -
399 -== **HMI and Wecon LX5V-N Ethernet communication** ==
400 -
401 -(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
402 -
403 -
404 -**Software configuration of PLC**
405 -
406 -**1)PLC programming software**
407 -
408 -[[image:image-20220810164710-1.png]]
409 -
410 -**2)New PLC project**
411 -
412 -Click New Project and select the PLC model.
413 -
414 -[[image:image-20220811115454-1.png]]
415 -
416 -
417 -**3)Set Ethernet port parameters**
418 -
419 -Follow the steps below to configure Ethernet parameters
420 -
421 -PLC IP address:192.168.39.200
422 -
423 -default gateway:192.168.39.1
424 -
425 -subnet mask:255.255.255.0
426 -
427 -[[image:image-20220811140530-2.png]]
428 -
429 -
430 -**4)Registers list**
431 -
432 -[[image:image-20220811102219-3.png]]
433 -
434 -
435 -**HMI software configuration**
436 -
437 -**1)HMI programming software**
438 -
439 - [[image:image-20220810171237-4.png]]
440 -
441 -**2)New HMI project**
442 -
443 -Click New Project and select the HMI model.
444 -
445 -[[image:image-20220810172010-5.png]]
446 -
447 -**3)Set communication port parameters**
448 -
449 -Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
450 -
451 -HMI IP address:192.168.39.201
452 -
453 -default gateway:192.168.39.1
454 -
455 -subnet mask:255.255.255.0
456 -
457 -[[image:image-20220811170753-2.png]]
458 -
459 -Next, click Communication Settings to configure the IP of the HMI communication object.
460 -
461 -[[image:image-20220811163047-1.png]]
462 -
463 -**hardware connection**
464 -
465 -**1)Hardware wiring diagram**
466 -
467 -This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
468 -
469 -[[image:image-20220811170248-1.png]]
470 -
471 -The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
472 -
473 -= =
474 -
475 475  = **Allen-Bradley** =
476 476  
477 477  == **FreeTag Ethernet/IP (CompactLogix)** ==
... ... @@ -580,7 +580,7 @@
580 580  * **Word address S:** The word address ranges from 0 to 255 (decimal).
581 581  * **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal).
582 582  
583 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
196 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit tare he same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
584 584  
585 585  |(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
586 586  |(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15
... ... @@ -2650,8 +2650,63 @@
2650 2650  
2651 2651  **✎Note:** COM3 only available in PI8000/PI9000 series.
2652 2652  
2653 -= =
2266 += **WECON PLC** =
2654 2654  
2268 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
2269 +
2270 +**HMI Settings**
2271 +
2272 +(% class="table-bordered" %)
2273 +|**Item**|**Settings**|**Note**
2274 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
2275 +|Connection|RS422/RS485|
2276 +|Baud rate|9600|
2277 +|Data bit|7|
2278 +|Parity|EVEN|
2279 +|Stop bit|1|
2280 +|PLC station No.|1|
2281 +
2282 +**Address List**
2283 +
2284 +(% class="table-bordered" %)
2285 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
2286 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
2287 +|Y|Y|Y o|0~~303237|
2288 +|M|M|M d|0~~99999|
2289 +|T|T|T d|0~~99999|
2290 +|C|C|C d|0~~99999|
2291 +|S|S|S d|0~~99999|
2292 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
2293 +|Y|Y|Y o|0~~303237|
2294 +|M|M|M d|0~~99999|
2295 +|T|T|T d|0~~99999|
2296 +|C|C|C d|0~~199|
2297 +|D|D|D d|0~~7999|
2298 +|S|S|S d|0~~99999|
2299 +|SD|SD|SD d|8000~~9999|
2300 +
2301 +**Cable Wiring**
2302 +
2303 +* **RS485**
2304 +
2305 +(% style="text-align:center" %)
2306 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
2307 +
2308 +(% style="text-align:center" %)
2309 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
2310 +
2311 +* **RS422**
2312 +
2313 +(% style="text-align:center" %)
2314 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
2315 +
2316 +**✎Note:**
2317 +
2318 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
2319 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
2320 +
2321 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
2322 +
2655 2655  = **Printer** =
2656 2656  
2657 2657  == **TSPL label printer** ==
... ... @@ -2819,20 +2819,174 @@
2819 2819  
2820 2820  **✎Note:** COM3 only available in PI8000/PI9000 series.
2821 2821  
2490 +== HMI and Wecon LX5V serial communication ==
2822 2822  
2492 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2493 +
2494 +**Software configuration of PLC**
2495 +
2496 +**1)PLC programming software**
2497 +
2498 +[[image:image-20220810164710-1.png]]
2499 +
2500 +**2)New PLC project**
2501 +
2502 +Click New Project and select the PLC model.
2503 +
2504 +[[image:image-20220810172412-1.png]]
2505 +
2506 +
2507 +**3)Set Serial port parameters**
2508 +
2509 +Follow the steps below to configure Serial port parameters
2510 +
2511 +Baud rate:115200
2512 +
2513 +Data bit:8
2514 +
2515 +Stop bit:1
2516 +
2517 +Parity:No verification
2518 +
2519 +[[image:image-20220810165759-3.png]]
2520 +
2521 +
2522 +**4)Registers list**
2523 +
2524 +[[image:image-20220811102219-3.png]]
2525 +
2526 +
2527 +**HMI software configuration**
2528 +
2529 +**1)HMI programming software**
2530 +
2531 + [[image:image-20220810171237-4.png]]
2532 +
2533 +**2)New HMI project**
2534 +
2535 +Click New Project and select the HMI model.
2536 +
2537 +[[image:image-20220810172010-5.png]]
2538 +
2539 +**3)Set communication port parameters**
2540 +
2541 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
2542 +
2543 +Baud rate:115200
2544 +
2545 +Data bit:8
2546 +
2547 +Stop bit:1
2548 +
2549 +Parity:No verification
2550 +
2551 +
2552 +[[image:image-20220811104012-1.png]]
2553 +
2554 +
2555 +**hardware connection**
2556 +
2557 +**1)Hardware wiring diagram**
2558 +
2559 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
2560 +
2561 +[[image:image-20220811103005-4.png]]
2562 +
2563 +
2564 +[[image:image-20220811103227-7.png]]
2565 +
2566 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
2567 +
2568 +== HMI and Wecon LX5V-N Ethernet communication ==
2569 +
2570 +(% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
2571 +
2572 +
2573 +**Software configuration of PLC**
2574 +
2575 +**1)PLC programming software**
2576 +
2577 +[[image:image-20220810164710-1.png]]
2578 +
2579 +**2)New PLC project**
2580 +
2581 +Click New Project and select the PLC model.
2582 +
2583 +[[image:image-20220811115454-1.png]]
2584 +
2585 +
2586 +**3)Set Ethernet port parameters**
2587 +
2588 +Follow the steps below to configure Ethernet parameters
2589 +
2590 +PLC IP address:192.168.39.200
2591 +
2592 +default gateway:192.168.39.1
2593 +
2594 +subnet mask:255.255.255.0
2595 +
2596 +[[image:image-20220811140530-2.png]]
2597 +
2598 +
2599 +**4)Registers list**
2600 +
2601 +[[image:image-20220811102219-3.png]]
2602 +
2603 +
2604 +**HMI software configuration**
2605 +
2606 +**1)HMI programming software**
2607 +
2608 + [[image:image-20220810171237-4.png]]
2609 +
2610 +**2)New HMI project**
2611 +
2612 +Click New Project and select the HMI model.
2613 +
2614 +[[image:image-20220810172010-5.png]]
2615 +
2616 +**3)Set communication port parameters**
2617 +
2618 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
2619 +
2620 +HMI IP address:192.168.39.201
2621 +
2622 +default gateway:192.168.39.1
2623 +
2624 +subnet mask:255.255.255.0
2625 +
2626 +[[image:image-20220811170753-2.png]]
2627 +
2628 +Next, click Communication Settings to configure the IP of the HMI communication object.
2629 +
2630 +[[image:image-20220811163047-1.png]]
2631 +
2632 +**hardware connection**
2633 +
2634 +**1)Hardware wiring diagram**
2635 +
2636 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
2637 +
2638 +[[image:image-20220811170248-1.png]]
2639 +
2640 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
2641 +
2823 2823  = **Schneider MODBUS RTU** =
2824 2824  
2825 2825  **HMI Setting**
2826 2826  
2827 -|=**Parameters**|=**Recommended**|=**Notes**
2828 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
2829 -|Connection|RS485|
2830 -|**Baud rate**|19200|
2831 -|**Data bit**|8|
2832 -|**Parity**|Even|
2833 -|**Stop bit**|1|
2834 -|**PLC station No.**|1|
2646 +|=(% scope="row" %)**Parameters**|=**Recommended**|=**Options**|=**Notes**
2647 +|=**PLC type**|(% colspan="2" %)Schneider MODBUS RTU|
2648 +|=**PLC I/F**|RS485|RS232/RS485|
2649 +|=**Baud rate**|19200|9600~~115200|
2650 +|=**Data bits**|8|7,8|
2651 +|=**Parity**|Even|Even, Odd, None|
2652 +|=**Stop bits**|1|1,2|
2653 +|=**PLC sta. no.**|1|0-255|
2835 2835  
2655 +|=(% scope="row" style="width: 266px;" %)**Online simulator**|(% style="width:319px" %)YES|(% style="width:336px" %)**Broadcast command**|(% style="width:155px" %)YES
2656 +|=(% style="width: 266px;" %)**Extend address mode**|(% style="width:319px" %)YES|(% style="width:336px" %) |(% style="width:155px" %)
2657 +
2836 2836  **PLC Setting**
2837 2837  
2838 2838  |=(% scope="row" %)**Communication mode**|Modbus RTU protocol
... ... @@ -2839,12 +2839,20 @@
2839 2839  
2840 2840  **Device Address**
2841 2841  
2842 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2843 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2844 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
2845 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2846 -|W|MW|DDDDDD|0 ~~ 999999|Output register
2847 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
2664 +|=(% scope="row" %)**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
2665 +|=B|%IX|DDDDDo|0 ~~ 655357|Input bit (read only)
2666 +|=B|%QX|DDDDDo|0 ~~ 655357|Write multiple coils
2667 +|=B|%MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
2668 +|=B|%M|DDDDD|0 ~~ 65535|Output bit
2669 +|=B|%MW_Bit|DDDDDdd|0 ~~ 6553515|Output register bit (decimal)
2670 +|=B|1x|DDDDD|0 ~~ 65535|Input bit (read only)
2671 +|=B|0x_multi_coils|DDDDD|0 ~~ 65535|Write multiple coils
2672 +|=B|3x_Bit|DDDDDdd|0 ~~ 6553515|Input register bit (read only)
2673 +|=W|%MW|DDDDDD|0 ~~ 999999|Output register
2674 +|=DW|%MD|DDDDDD|0 ~~ 999999|Output register
2675 +|=W|3x|DDDDD|0 ~~ 65535|Input Register (read only)
2676 +|=DW|5x|DDDDD|0 ~~ 65535|4x double word swap
2677 +|=DW|6x|DDDDD|0 ~~ 65535|4x single word write
2848 2848  
2849 2849  **Wiring Diagram**
2850 2850  
image-20220819093729-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -10.3 KB
Content
image-20220819093729-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -79.4 KB
Content
image-20220819093729-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -147.9 KB
Content
image-20220819093729-15.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -74.6 KB
Content
image-20220819093729-17.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -115.0 KB
Content
image-20220819093729-18.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -112.1 KB
Content
image-20220819093729-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -34.1 KB
Content
image-20220819093729-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -44.2 KB
Content
image-20220819093729-4 (1).png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -82.4 KB
Content
image-20220819093729-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -82.4 KB
Content
image-20220819093729-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -6.6 KB
Content
image-20220819093729-6.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -100.2 KB
Content
image-20220819093729-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -46.9 KB
Content
image-20220819093730-19.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -122.5 KB
Content
image-20220819093730-20.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -99.6 KB
Content
image-20220819101447-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -56.6 KB
Content
image-20220819105530-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -1.0 MB
Content
image-20220819105630-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -1.1 MB
Content
image-20220819105644-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -942.6 KB
Content
image-20220819105928-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -72.6 KB
Content
image-20220820150853-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -171.7 KB
Content