Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,59 +87,6 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 - 91 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 92 - 93 -**HMI Settings** 94 - 95 -(% class="table-bordered" %) 96 -|**Item**|**Settings**|**Note** 97 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 98 -|Connection|RS422/RS485| 99 -|Baud rate|9600| 100 -|Data bit|7| 101 -|Parity|EVEN| 102 -|Stop bit|1| 103 -|PLC station No.|1| 104 - 105 -**Address List** 106 - 107 -(% class="table-bordered" %) 108 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 109 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 110 -|Y|Y|Y o|0~~303237| 111 -|M|M|M d|0~~99999| 112 -|T|T|T d|0~~99999| 113 -|C|C|C d|0~~99999| 114 -|S|S|S d|0~~99999| 115 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 116 -|Y|Y|Y o|0~~303237| 117 -|M|M|M d|0~~99999| 118 -|T|T|T d|0~~99999| 119 -|C|C|C d|0~~199| 120 -|D|D|D d|0~~7999| 121 -|S|S|S d|0~~99999| 122 -|SD|SD|SD d|8000~~9999| 123 - 124 -**Cable Wiring** 125 - 126 -* **RS485** 127 - 128 -(% style="text-align:center" %) 129 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 130 - 131 -* **RS422** 132 - 133 -(% style="text-align:center" %) 134 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 135 - 136 -**✎Note:** 137 - 138 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 139 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 140 - 141 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 142 - 143 143 == HMI settings == 144 144 145 145 **Download PIStudio Software** ... ... @@ -316,8 +316,59 @@ 316 316 317 317 = **WECON PLC** = 318 318 266 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 319 319 268 +**HMI Settings** 320 320 270 +(% class="table-bordered" %) 271 +|**Item**|**Settings**|**Note** 272 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 273 +|Connection|RS422/RS485| 274 +|Baud rate|9600| 275 +|Data bit|7| 276 +|Parity|EVEN| 277 +|Stop bit|1| 278 +|PLC station No.|1| 279 + 280 +**Address List** 281 + 282 +(% class="table-bordered" %) 283 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 284 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 285 +|Y|Y|Y o|0~~303237| 286 +|M|M|M d|0~~99999| 287 +|T|T|T d|0~~99999| 288 +|C|C|C d|0~~99999| 289 +|S|S|S d|0~~99999| 290 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 291 +|Y|Y|Y o|0~~303237| 292 +|M|M|M d|0~~99999| 293 +|T|T|T d|0~~99999| 294 +|C|C|C d|0~~199| 295 +|D|D|D d|0~~7999| 296 +|S|S|S d|0~~99999| 297 +|SD|SD|SD d|8000~~9999| 298 + 299 +**Cable Wiring** 300 + 301 +* **RS485** 302 + 303 +(% style="text-align:center" %) 304 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 305 + 306 +* **RS422** 307 + 308 +(% style="text-align:center" %) 309 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 310 + 311 +**✎Note:** 312 + 313 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 314 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 315 + 316 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 317 + 318 + 321 321 == **HMI and Wecon LX5V serial communication** == 322 322 323 323 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. ... ... @@ -470,6 +470,7 @@ 470 470 471 471 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 472 472 471 +(% class="wikigeneratedid" %) 473 473 = = 474 474 475 475 = **Allen-Bradley** =