Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 66.1
edited by Ben
on 2022/08/29 14:06
Change comment: There is no comment for this version
To version 123.1
edited by Ben
on 2022/08/30 14:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,7 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 +== **LX3V Serial Protocol** ==
90 90  
91 91  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 92  
... ... @@ -140,7 +140,8 @@
140 140  
141 141  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 142  
143 -== HMI settings ==
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
144 144  
145 145  **Download PIStudio Software**
146 146  
... ... @@ -229,7 +229,8 @@
229 229  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 230  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 231  
232 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
233 233  
234 234  **Download PLC Software**
235 235  
... ... @@ -314,7 +314,7 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **HMI and Wecon LX5V serial communication** =
320 +== **LX5V Serial Protocol** ==
318 318  
319 319  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
320 320  
... ... @@ -392,11 +392,10 @@
392 392  
393 393  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
394 394  
395 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
396 396  
397 397  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
398 398  
399 -
400 400  **Software configuration of PLC**
401 401  
402 402  **1)PLC programming software**
... ... @@ -466,12 +466,51 @@
466 466  
467 467  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
468 468  
469 -= =
471 += Create communication with **Rockwell PLC** =
470 470  
471 -= **Allen-Bradley** =
473 +== **MicroLogix Protocol** ==
472 472  
473 -== **FreeTag Ethernet/IP (CompactLogix)** ==
475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
474 474  
477 +**HMI Settings**
478 +
479 +(% class="table-bordered" %)
480 +|**Item**|**Settings**|**Note**
481 +|Protocol|Allen-Bradlley MicroLogix|
482 +|Connection|RS232|
483 +|Baud rate|19200|
484 +|Data bit|8|
485 +|Parity|None|
486 +|Stop bit|1|
487 +|PLC station No.|1|
488 +
489 +**Address List**
490 +
491 +(% class="table-bordered" %)
492 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
494 +|O|O d.d|0.0~~255.15|
495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
496 +|S|S d.d|0.0~~255.15|
497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|(% rowspan="9" %)Word|S|S d|0~~255|
499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
500 +|TP|TP nnhh|0~~ffff
501 +|CS|CS nnhh|0~~ffff
502 +|CP|CP nnhh|0~~ffff
503 +|N|N nnhh|0~~ffff
504 +|C|C nnhh|0~~ffff
505 +|T|T nnhh|0~~ffff
506 +|R|R nnhh|0~~ffff
507 +
508 +**Cable Wiring**
509 +
510 +
511 +(% style="text-align:center" %)
512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 +
514 +== **CompactLogix FreeTag Ethernet protocol** ==
515 +
475 475  Allen-Brandly CompactLogix
476 476  
477 477  **HMI Settings**
... ... @@ -527,48 +527,8 @@
527 527  (% style="text-align:center" %)
528 528  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
529 529  
530 -== **MicroLogix** ==
571 +== **MicroLogix 1200** ** protocol** ==
531 531  
532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
533 -
534 -**HMI Settings**
535 -
536 -(% class="table-bordered" %)
537 -|**Item**|**Settings**|**Note**
538 -|Protocol|Allen-Bradlley MicroLogix|
539 -|Connection|RS232|
540 -|Baud rate|19200|
541 -|Data bit|8|
542 -|Parity|None|
543 -|Stop bit|1|
544 -|PLC station No.|1|
545 -
546 -**Address List**
547 -
548 -(% class="table-bordered" %)
549 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
551 -|O|O d.d|0.0~~255.15|
552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
553 -|S|S d.d|0.0~~255.15|
554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
555 -|(% rowspan="9" %)Word|S|S d|0~~255|
556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
557 -|TP|TP nnhh|0~~ffff
558 -|CS|CS nnhh|0~~ffff
559 -|CP|CP nnhh|0~~ffff
560 -|N|N nnhh|0~~ffff
561 -|C|C nnhh|0~~ffff
562 -|T|T nnhh|0~~ffff
563 -|R|R nnhh|0~~ffff
564 -
565 -**Cable Wiring**
566 -
567 -(% style="text-align:center" %)
568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
569 -
570 -== **AB PLC address edit** ==
571 -
572 572  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
573 573  
574 574  * **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal).
... ... @@ -584,117 +584,280 @@
584 584  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
585 585  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
586 586  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
587 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
588 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
589 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
590 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
591 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
592 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
593 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
594 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
595 595  
596 -= **Barcode Scanner** =
597 += Create communication with (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens PLC** =
597 597  
598 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet Protocol** ==
599 599  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
600 600  **HMI Setting**
601 601  
602 602  (% class="table-bordered" %)
603 603  |**Items**|**Settings**|**Note**
604 -|Protocol|Barcode Scanner|
605 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
606 606  
607 -**Operating Procedures**
614 +**Address List**
608 608  
609 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
610 610  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
611 611  (% style="text-align:center" %)
612 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
613 613  
614 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
615 615  
616 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
617 617  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
618 618  (% style="text-align:center" %)
619 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
620 620  
621 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
622 622  
623 -* The protocol uploads the information acquired by the USB scanner to the HMI;
624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
625 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
626 626  
627 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
628 628  
629 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet Protocol** ==
630 630  
631 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
632 632  
694 +**HMI Setting**
695 +
633 633  (% class="table-bordered" %)
634 634  |**Items**|**Settings**|**Note**
635 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
636 636  |Connection|Ethernet|
637 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
638 638  
639 639  **Address List**
640 640  
641 641  (% class="table-bordered" %)
642 -|**Type**|**Register**|**Range**|**Format**|**Note**
643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
644 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
646 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
647 647  
648 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
649 649  
650 -H2: Unit number
721 +MW2=MB(2~~3)
651 651  
652 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
653 653  
654 -H4: Word number of Module
728 +MD4=MB(4~~7)
655 655  
656 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
657 657  
658 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
659 659  
660 -Slot number 2
740 +**Communication Settings**
661 661  
662 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
663 663  
664 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
665 665  
666 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet Protocol** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
667 667  )))
668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
669 -|R|0 – FF.f (Hex)|R HH.h|
670 -|L|0 - 73FF.f (Hex)|L HHHH.h|
671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
673 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
674 674  
675 -H1: Remote number
815 +MW2=MB(2~~3)
676 676  
677 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
678 678  
679 -H3: Slot number
822 +MD4=MB(4~~7)
680 680  
681 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
682 682  
683 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
684 684  
685 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
686 686  
687 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
688 688  
689 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
690 690  )))
691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
692 -|WR|0 – FFFF (Hex)|WR HHHH|
693 -|WL|0 - 73FF (Hex)|WL HHHH|
694 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
695 695  
696 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
697 697  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
698 698  Enable HMI Ethernet in [Project Settings];
699 699  
700 700  (% style="text-align:center" %)
... ... @@ -703,180 +703,286 @@
703 703  Set PLC IP in [Device IP] settings;
704 704  
705 705  (% style="text-align:center" %)
706 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
707 707  
708 -**PLC Configuration**
872 +**✎Note:**
709 709  
710 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
711 711  
712 -(% style="text-align:center" %)
713 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
714 714  
715 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
716 716  
881 +* Please uncheck [Symbolic access only] option;
882 +
717 717  (% style="text-align:center" %)
718 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
719 719  
720 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
721 721  
722 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
723 723  
724 -Connect with PLC and choose to “online” mode
892 +**Such as:**
725 725  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
726 726  (% style="text-align:center" %)
727 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
728 728  
729 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
730 730  
731 -(% style="text-align:center" %)
732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
733 733  
734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
735 735  
736 736  (% style="text-align:center" %)
737 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
738 738  
739 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
740 740  
741 741  (% style="text-align:center" %)
742 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
743 743  
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
746 746  
747 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
748 748  
749 -* Both word registers and bit registers support even continuous read/write functions;
750 -* The range of registers is based on the specific PLC type;
751 -
752 752  **Cable Wiring**
753 753  
754 754  (% style="text-align:center" %)
755 755  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
756 756  
757 -= **IEC60870-5 104 Client** =
925 +== **S7-XXX Ethernet Protocol** ==
758 758  
927 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
928 +
759 759  **HMI Setting**
760 760  
761 -(% class="table-bordered" %)
762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
931 +(% class="table-bordered" style="width:823px" %)
932 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
933 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
934 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
935 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
936 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
937 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
766 766  
939 +Slot from TIA Portal is equal to Device No. of PIStudio
940 +
941 +Rack from TIA Portal is equal to HMI No. of PIStudio
942 +
943 +(% style="text-align:center" %)
944 +[[image:S7-XXXCommunication Settings.png]]
945 +
946 +(% style="text-align:center" %)
947 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
948 +
767 767  **Address List**
768 768  
769 769  (% class="table-bordered" %)
770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
772 -|(% style="width:461px" %)SCNA|0~~16777215.7
773 -|(% style="width:461px" %)DPTB|0~~16777215.7
774 -|(% style="width:461px" %)DCNA|0~~16777215.7
775 -|(% style="width:461px" %)METF|0~~16777215.7
776 -|(% style="width:461px" %)SENC|0~~16777215.7
777 -|(% style="width:461px" %)SENA|0~~16777215.7
778 -|(% style="width:461px" %)MENA|0~~16777215.7
779 -|(% style="width:461px" %)METD|0~~16777215.7
780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
781 -|(% style="width:461px" %)SCNA|0~~16777215
782 -|(% style="width:461px" %)DPTB|0~~16777215
783 -|(% style="width:461px" %)DCNA|0~~16777215
784 -|(% style="width:461px" %)SENA|0~~16777215
785 -|(% style="width:461px" %)MENA|0~~16777215
786 -|(% style="width:461px" %)METD|0~~16777215
787 -|(% style="width:461px" %)INRO|0~~16777215
788 -|(% style="width:461px" %)TIMESYN|0~~16777215
789 -|(% style="width:461px" %)TIMEZ|0~~16777215
790 -|(% style="width:461px" %)NTP|0~~16777215
791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
792 -|(% style="width:461px" %)SENC|0~~16777215
952 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
953 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
954 +d:0~-~-9999
793 793  
794 -**Address Configuration**
956 +o:0-7
957 +)))|
958 +|Q|Q|Q d.o|(((
959 +d:0~-~-9999
795 795  
796 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
961 +o:0-7
962 +)))|
963 +|M|M|M d.o|(((
964 +d:0~-~-9999
797 797  
798 -(% style="text-align:center" %)
799 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
966 +o:0-7
967 +)))|
968 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
969 +nn:0-9999,
800 800  
801 -(% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
971 +dddd:0-9999,
803 803  
804 -Extended tag name
973 +o:0-7
974 +)))|(((
975 +nn:DB No.
805 805  
806 -Address range for the extended tag.
977 +dddd:address value
807 807  
979 +o: digit address
980 +)))
981 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
982 +|M|MW|MW d|d:0-99999|(((
983 +MW0=MB(0~~1)
984 +
985 +MW2=MB(2~~3)
986 +
987 +Address value is a multiple of 2
988 +)))
989 +|M|MD|MD d|d:0-99999|(((
990 +MD0=MB(0~~3)
991 +
992 +MD4=MB(4~~7)
993 +
994 +Address value is a multiple of 4
995 +)))
996 +|I|IW|IW d|d:0-99999|
997 +|Q|QW|QW d|d:0-99999|
998 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
999 +nn:0-9999
1000 +
1001 +dddd:0-9999
1002 +)))|(((
1003 +nn:DB No.
1004 +
1005 +dddd:address value
1006 +)))
1007 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1008 +nn:0-9999
1009 +
1010 +dddd:0-9999
1011 +)))|(((
1012 +nn:DB No.
1013 +
1014 +dddd:address value
1015 +
1016 +Address value is a multiple of 2
1017 +)))
1018 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1019 +nn:0-9999
1020 +
1021 +dddd:0-9999
1022 +)))|(((
1023 +nn:DB No.
1024 +
1025 +dddd:address value
1026 +
1027 +Address value is a multiple of 4
1028 +)))
1029 +
808 808  **Communication Settings**
809 809  
810 810  Enable HMI Ethernet in [Project Settings];
811 811  
812 812  (% style="text-align:center" %)
813 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1035 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
814 814  
815 815  Set PLC IP in [Device IP] settings;
816 816  
817 817  (% style="text-align:center" %)
818 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
1040 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
819 819  
1042 +**✎Note:**
1043 +
1044 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1045 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1046 +
820 820  **Cable Wiring**
821 821  
822 -(% style="text-align:center" %)
823 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1049 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
824 824  
825 -= **LG XGK FEnet Ethernet** =
1051 +== (% id="cke_bm_25456S" style="display:none" %)** **(%%)**LOGO Ethernet Protocol** ==
826 826  
827 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1053 +Supported Series: Siemens Logo 0BA0 series
828 828  
829 829  **HMI Settings**
830 830  
831 831  (% class="table-bordered" %)
832 832  |**Items**|**Settings**|**Note**
833 -|Protocol|LG XGK FEnet(Ethernet)|
1059 +|Protocol|Siemens LOGO|
834 834  |Connection|Ethernet|
835 -|Port No.|2004|
1061 +|Port No.|102|
1062 +|PLC station No.|2|
836 836  
837 837  **Address List**
838 838  
839 839  (% class="table-bordered" %)
840 -|**Type**|**Register**|**Range**|**Format**|**Note**
841 -|(% rowspan="14" %)Word|P|0~~2047|P d|
842 -|M|0~~2047|M d|
843 -|K|0~~2047|K d|
844 -|F|0~~2047|F d|
845 -|T|0~~2047|T d|
846 -|C|0~~2047|C d|
847 -|Z|0~~127|Z d|
848 -|S|0~~127|S d|
849 -|L|0~~11263|L d|
850 -|N|0~~21503|N d|
851 -|D|0~~32767|D d|
852 -|R|0~~32767|R d|
853 -|ZR|0~~65535|ZR d|
854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1067 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
1068 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
1069 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
1070 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
1071 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
1072 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
1073 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
1074 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
1075 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
1076 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
1077 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
1078 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
1079 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
1080 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
1081 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
1082 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
855 855  
856 -**✎Note:**
1084 +**PLC Settings in LOGO Software:**
857 857  
858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
860 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1086 +Click [Tools]~-~-[Ethernet Connections],shown as below.
861 861  
862 -**Communication settings in HMI**
1088 +(% style="text-align:center" %)
1089 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
863 863  
864 -Enable HMI Ethernet in [Project Settings];
1091 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
865 865  
866 866  (% style="text-align:center" %)
867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1094 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
868 868  
1096 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
1097 +
1098 +(% style="text-align:center" %)
1099 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
1100 +
1101 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
1102 +
1103 +(% style="text-align:center" %)
1104 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
1105 +
1106 +
1107 +(% style="text-align:center" %)
1108 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
1109 +
1110 +
1111 +**HMI Communication Settings**
1112 +
869 869  Set PLC IP in [Device IP] settings;
870 870  
871 871  (% style="text-align:center" %)
872 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1116 +[[image:SiemensLOGODeviceIP.png]]
873 873  
1118 +Enable HMI Ethernet in [Project Settings];
1119 +
1120 +(% style="text-align:center" %)
1121 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
1122 +
1123 +TSAP setting
1124 +
1125 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1126 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1127 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1128 +
1129 +**✎Note:**
1130 +
1131 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1132 +
1133 +(% style="text-align:center" %)
1134 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1135 +
1136 +
1137 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1138 +* VW address should be even number.such as VW0, VW2, VW4...
1139 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1140 +* Written value of RTC cannot exceed 255.
1141 +
874 874  **Cable Wiring**
875 875  
876 -= **Mitsubishi** =
1144 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
877 877  
878 -== **FX1S, 1N, 2N Series** ==
1146 += Create communication with **Mitsubishi PLC** =
879 879  
1148 +== **FX1S, 1N, 2N Series Protocol** ==
1149 +
880 880  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
881 881  
882 882  **HMI Settings**
... ... @@ -928,7 +928,7 @@
928 928  
929 929  **✎Note:** COM3 only available in PI8000/PI9000 series.
930 930  
931 -== **FX5U Ethernet** ==
1201 +== **FX5U Ethernet Protocol** ==
932 932  
933 933  Mitsubishi FX5U series PLC
934 934  
... ... @@ -1007,7 +1007,7 @@
1007 1007  (% style="text-align:center" %)
1008 1008  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1009 1009  
1010 -== **FX5U Serial Port** ==
1280 +== **FX5U Serial Port Protocol** ==
1011 1011  
1012 1012  Mitsubishi FX5U series PLC
1013 1013  
... ... @@ -1099,7 +1099,7 @@
1099 1099  
1100 1100  **✎Note:** COM3 only available in PI8000/PI9000 series.
1101 1101  
1102 -== **L02 MELSEC (Ethernet)** ==
1372 +== **L02 MELSEC (Ethernet) Protocol** ==
1103 1103  
1104 1104  Mitsubishi Q series CPU built-in Ethernet port.
1105 1105  
... ... @@ -1184,7 +1184,7 @@
1184 1184  (% style="text-align:center" %)
1185 1185  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1186 1186  
1187 -== **QJ71E71 MELSEC** ==
1457 +== **QJ71E71 MELSEC Protocol** ==
1188 1188  
1189 1189  Mitsubishi QJ71E71 Ethernet communication module;
1190 1190  
... ... @@ -1264,219 +1264,200 @@
1264 1264  (% style="text-align:center" %)
1265 1265  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1266 1266  
1267 -= **MODBUS** =
1537 += Create communication with **Delta PLC** =
1268 1268  
1269 -== **MODBUS RTU Master** ==
1539 +== **DVP serial protocol** ==
1270 1270  
1271 -Supported Series: MODBUS RTU CONTROLLER
1541 +(% class="wikigeneratedid" %)
1542 +Supported Series: Delta DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX Controller
1272 1272  
1273 -HMI works as MODBUS SLAVE connecting with MASTER
1544 +**1)HMI Settings**
1274 1274  
1275 -(% style="text-align:center" %)
1276 -[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1546 +|**Item**|**Settings**|**Note**
1547 +|Protocol|DELTA DVP Series|
1548 +|Connection|RS485|
1549 +|Baud rate|9600|
1550 +|Data bit|7|
1551 +|Parity|Even|
1552 +|Stop bit|1|
1553 +|PLC station No.|1~~255|Need to be the same as PLC settings
1277 1277  
1555 +**2)Address List**
1278 1278  
1279 -(% style="text-align:center" %)
1280 -[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1557 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1558 +|Bit|X|X|X d|0~~303237|
1559 +|Bit|Y|Y|Y d|0~~303237|
1560 +|Bit|M|M|M d|0~~99999|
1561 +|Bit|T|T|T d|0~~99999|
1562 +|Bit|C|C|T d|0~~99999|
1563 +|Bit|S|S|T d|0~~99999|
1564 +|Word|D|D|D d|0~~99999|
1565 +|Word|T|T|T d|0~~99999|
1566 +|Word|C|C|C d|0~~99999|
1281 1281  
1568 +(% class="wikigeneratedid" %)
1569 +**3)Configure the communication protocol**
1282 1282  
1283 -(% style="text-align:center" %)
1284 -[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1571 +(% class="wikigeneratedid" %)
1572 +[[image:image-20220829152327-6.png]]
1285 1285  
1286 -**HMI Settings**
1574 +(% class="wikigeneratedid" %)
1575 +[[image:image-20220829152016-3.png]]
1287 1287  
1288 -(% class="table-bordered" %)
1289 -|**Items**|**Settings**|**Note**
1290 -|Protocol|MODBUS RTU Master|
1291 -|Connection|RS485/RS232|
1292 -|Baud rate|2400~~187500|
1293 -|Data bit|8|
1294 -|Parity|Even/ Odd/ None|
1295 -|Stop bit|1/2|
1296 -|Station No.|0~~255|
1577 +(% class="wikigeneratedid" %)
1578 +**4)Cable Wiring**
1297 1297  
1298 -**Address List**
1580 +(% class="wikigeneratedid" id="H" %)
1581 +[[image:image-20220829152610-7.png]]
1299 1299  
1300 -(% class="table-bordered" %)
1301 -|**Type**|**HMI address**|**MODBUS code**|**Range**
1302 -|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1303 -|Word|HDW3500~~HDW7999|4|0~~4499
1583 +(% class="wikigeneratedid" id="H" %)
1584 +[[image:image-20220829152102-5.png]]
1304 1304  
1305 -**Cable Wiring**
1306 1306  
1307 -* **RS485**
1587 +== **DVP Ethernet Protocol** ==
1308 1308  
1309 -(% style="text-align:center" %)
1310 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1589 +(% class="wikigeneratedid" %)
1590 +Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller
1311 1311  
1312 -(% style="text-align:center" %)
1313 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1592 +**1)HMI Settings**
1314 1314  
1315 -* **RS232**
1594 +|**Items**|**Settings**|**Note**
1595 +|Protocol|DELTA DVP Modbus TCP|
1596 +|Connection|Ethernet|
1597 +|Port No.|201|Must be the same as the PLC setting
1598 +|PLC station No.|0|Must be the same as the PLC setting
1316 1316  
1317 -(% style="text-align:center" %)
1318 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1600 +**2)Address List**
1319 1319  
1320 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1602 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1603 +|Bit|X|X|X o|0~~377|
1604 +|Bit|Y|Y|Y o|0~~377|
1605 +|Bit|M0|M0|M0 d|0~~1535|
1606 +|Bit|M1|M1|M1 d|1536~~4095|
1607 +|Bit|T|T|T d|0~~255|
1608 +|Bit|C|C|C d|0~~255|
1609 +|Bit|S|S|S d|0~~1023|
1610 +|Word|D0|D0|D0 d|0~~4095|
1611 +|Word|D1|D1|D1 d|4096~~11999|(((
1612 +
1613 +)))
1614 +|Word|T|T|T d|0~~255|
1615 +|Word|C|C|C d|0~~199|(((
1616 +
1617 +)))
1321 1321  
1322 -== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1619 +(% class="wikigeneratedid" %)
1620 +**3)Configure the communication protocol**
1323 1323  
1324 -Supported Series: MODBUS RTU CONTROLLER
1622 +[[image:image-20220829155452-1.png]]
1325 1325  
1326 -HMI works as MODBUS MASTER connecting with SLAVE.
1624 +[[image:image-20220829162116-2.png]]
1327 1327  
1328 -The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1626 +**4)Cable Wiring**
1329 1329  
1330 -(% style="text-align:center" %)
1331 -[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1628 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1332 1332  
1630 +== **AS serial protocol** ==
1333 1333  
1334 -(% style="text-align:center" %)
1335 -[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1632 +**1)HMI Settings**
1336 1336  
1337 -
1338 -(% style="text-align:center" %)
1339 -[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1340 -
1341 -**HMI Settings**
1342 -
1343 -(% class="table-bordered" %)
1344 -|**Items**|**Settings**|**Note**
1345 -|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1346 -|Connection|RS485/RS232|
1347 -|Baud rate|2400~~187500|
1634 +|**Item**|**Settings**|**Note**
1635 +|Protocol|DELTA AS300 MODBUS RTU|
1636 +|Connection|RS485|
1637 +|Baud rate|9600|
1348 1348  |Data bit|8|
1349 -|Parity|Even/ Odd/ None|
1350 -|Stop bit|1/2|
1351 -|PLC station No.|0~~255|
1639 +|Parity|NONE|
1640 +|Stop bit|1|
1641 +|PLC station No.|1|
1352 1352  
1353 -**Address List**
1643 +**2)Address List**
1354 1354  
1355 -(% class="table-bordered" %)
1356 -|**Type**|**Address Type**|**Function code & Description**
1357 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1358 -|06 (write single register: write a binary value to a holding register)
1359 -|10 (write values to multiple addresses )
1360 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1361 -|06 (write single register: write a binary value to a holding register)
1362 -|10 (write values to multiple addresses )
1363 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1364 -|06 (write single register: write a binary value to a holding register)
1365 -|10 (write values to multiple addresses )
1366 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1367 -|10 (write values to multiple addresses )
1368 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1369 -|05 (Force a single coil to force the on/off state of a logic coil)
1370 -|0F (Write multiple bits, ie write continuously)
1371 -|(% rowspan="3" %)1|02 (Read the input state)
1372 -|05 (Force a single coil to force the on/off state of a logic coil)
1373 -|0F (Write multiple bits)
1374 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1375 -|05 (Force a single coil to force the on/off state of a logic coil)
1376 -|0F (Write multiple bits)
1377 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1378 -|0F (Write multiple bits)
1379 1379  
1380 -**✎Note:**
1646 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1647 +|Bit|X|X|X d|0~~63|
1648 +|Bit|Y|Y|Y d|0~~63|
1649 +|Bit|D|D|D d|0~~29999|
1650 +|Bit|M|M|M d|0~~8191|
1651 +|Bit|SM|SM|SM d|0~~4095|
1652 +|Bit|S|S|S h|0~~2047|
1653 +|Bit|T|T|T d|0~~511|
1654 +|Bit|C|C|C d|0~~511|
1655 +|Bit|HC|HC|HC d|0~~255|
1656 +|Word|X|X|X h|0~~63|
1657 +|Word|Y|Y|Y d|0~~63|
1658 +|Word|SR|SR|SR d|0~~2047|
1659 +|Word|D|D|D d|0~~29999|
1660 +|Word|T|T|T d|0~~511|
1661 +|Word|C|C|C h|0~~511|
1662 +|Word|E|E|E d|0~~9|
1381 1381  
1382 -* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1383 -* The function codes sent out are the same as those that read and write words.
1664 +**3)Configure the communication protocol**
1384 1384  
1385 -**Station number for more than one slaves**
1666 +[[image:image-20220830094600-1.png]]
1386 1386  
1387 -If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1668 +[[image:image-20220830094657-2.png]]
1388 1388  
1389 -(% style="text-align:center" %)
1390 -[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1670 +**4)Cable Wiring**
1391 1391  
1392 -**Cable Wiring**
1672 +Figure
1393 1393  
1394 -* **RS485**
1674 +[[image:image-20220830141138-1.png]]
1395 1395  
1396 -(% style="text-align:center" %)
1397 -[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1676 +Pin Definition Diagram
1398 1398  
1399 -(% style="text-align:center" %)
1400 -[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1678 +[[image:image-20220830095131-1.png]]
1401 1401  
1402 -* **RS232**
1680 +== **AS Ethernet Protocol** ==
1403 1403  
1404 -(% style="text-align:center" %)
1405 -[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1682 +**1)HMI Settings**
1406 1406  
1407 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1408 1408  
1409 -== **MODBUS TCP Slave (All function)** ==
1410 -
1411 -Supported series: MODBUS TCP controller
1412 -
1413 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1414 -
1415 -(% style="text-align:center" %)
1416 -[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1417 -
1418 -(% style="text-align:center" %)
1419 -[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1420 -
1421 -
1422 -(% style="text-align:center" %)
1423 -[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1424 -
1425 -**HMI Setting**
1426 -
1427 -(% class="table-bordered" %)
1428 -|**Items**|**Settings**|**Note**
1429 -|Protocol|MODBUS TCP Slave (All function)|
1685 +|=**Items**|=**Settings**|=**Note**
1686 +|Protocol|DELTA AS300 MODBUS TCP|
1430 1430  |Connection|Ethernet|
1431 1431  |Port No.|502|
1432 -|PLC station No.|1|
1689 +|Device No.|1|
1690 +|HMI No.|0|
1433 1433  
1434 -**Address List**
1692 +**2)Address List**
1435 1435  
1436 -(% class="table-bordered" %)
1437 -|**Type**|**Register**|**Function code & Description**
1438 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1439 -|06 (write single register: write a binary value to a holding register)
1440 -|10 (write values to multiple addresses )
1441 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1442 -|06 (write single register: write a binary value to a holding register)
1443 -|10 (write values to multiple addresses )
1444 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1445 -|06 (write single register: write a binary value to a holding register)
1446 -|10 (write values to multiple addresses )
1447 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1448 -|10 (write values to multiple addresses )
1449 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1450 -|05 (Force a single coil to force the on/off state of a logic coil)
1451 -|0F (Write multiple bits, ie write continuously)
1452 -|(% rowspan="3" %)1|02 (Read the input state)
1453 -|05 (Force a single coil to force the on/off state of a logic coil)
1454 -|0F (Write multiple bits)
1455 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1456 -|05 (Force a single coil to force the on/off state of a logic coil)
1457 -|0F (Write multiple bits)
1458 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1459 -|0F (Write multiple bits)
1460 1460  
1461 -**Communication Settings**
1695 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1696 +|Bit|X|X|X d|0~~63|
1697 +|Bit|Y|Y|Y d|0~~63|
1698 +|Bit|D|D|D d|0~~29999|
1699 +|Bit|M|M|M d|0~~8191|
1700 +|Bit|SM|SM|SM d|0~~4095|
1701 +|Bit|S|S|S h|0~~2047|
1702 +|Bit|T|T|T d|0~~511|
1703 +|Bit|C|C|C d|0~~511|
1704 +|Bit|HC|HC|HC d|0~~255|
1705 +|Word|X|X|X h|0~~63|
1706 +|Word|Y|Y|Y d|0~~63|
1707 +|Word|SR|SR|SR d|0~~2047|
1708 +|Word|D|D|D d|0~~29999|
1709 +|Word|T|T|T d|0~~511|
1710 +|Word|C|C|C h|0~~511|
1711 +|Word|E|E|E d|0~~9|
1462 1462  
1463 -Enable HMI Ethernet in [Project Settings];
1713 +**3)Configure the communication protocol**
1464 1464  
1465 -(% style="text-align:center" %)
1466 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1715 +[[image:image-20220830140537-1.png]]
1467 1467  
1468 -Set PLC IP in [Device IP] settings;
1717 +[[image:image-20220830140629-2.png]]
1469 1469  
1470 -(% style="text-align:center" %)
1471 -[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1719 +**4)Cable Wiring**
1472 1472  
1473 -**Cable Wiring**
1721 +Figure
1474 1474  
1475 -(% style="text-align:center" %)
1476 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1723 +[[image:image-20220830094929-1.png]]
1477 1477  
1478 -= **Omron** =
1725 +Pin Definition Diagram
1479 1479  
1727 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1728 +
1729 += ** Omron** =
1730 +
1480 1480  == **EC55** ==
1481 1481  
1482 1482  Supported device: EC55 temperature instrument
... ... @@ -1483,7 +1483,6 @@
1483 1483  
1484 1484  **HMI Settings**
1485 1485  
1486 -(% class="table-bordered" %)
1487 1487  |**Items**|**Settings**|**Note**
1488 1488  |Protocol|Omron EC55|
1489 1489  |Connection|RS485 (9600, 2, 7, EVEN)|
... ... @@ -1492,7 +1492,6 @@
1492 1492  
1493 1493  **Address List**
1494 1494  
1495 -(% class="table-bordered" %)
1496 1496  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
1497 1497  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1498 1498  |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
... ... @@ -1538,7 +1538,7 @@
1538 1538  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1539 1539  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1540 1540  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1541 -* (% id="cke_bm_8690S" style="display:none" %)[[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]](%%)Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1790 +* [[image:12.PLC Protocol_html_d428cad280fdefb3.png||height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1542 1542  
1543 1543  == EtherNet/IP NX series ==
1544 1544  
... ... @@ -1546,7 +1546,6 @@
1546 1546  
1547 1547  **HMI Setting**
1548 1548  
1549 -(% class="table-bordered" %)
1550 1550  |**Items**|**Settings**|**Note**
1551 1551  |Protocol|Omron NX Ethernet/IP|
1552 1552  |Connection|Ethernet|
... ... @@ -1598,183 +1598,224 @@
1598 1598  (% style="text-align:center" %)
1599 1599  [[image:12.PLC Protocol_html_437cb087b36b5784.png||data-xwiki-image-style-alignment="center" height="330" width="600" class="img-thumbnail"]]
1600 1600  
1601 -
1602 1602  (% style="text-align:center" %)
1603 1603  [[image:12.PLC Protocol_html_60ef71528a99abf5.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
1604 1604  
1605 1605  **Cable Wiring**
1606 1606  
1854 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1855 +
1856 += **MODBUS** =
1857 +
1858 +== **MODBUS RTU Master** ==
1859 +
1860 +Supported Series: MODBUS RTU CONTROLLER
1861 +
1862 +HMI works as MODBUS SLAVE connecting with MASTER
1863 +
1607 1607  (% style="text-align:center" %)
1608 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1865 +[[image:12.PLC Protocol_html_44425b313b0a6b96.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1609 1609  
1610 -= **OpenCAN** =
1611 1611  
1612 -OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
1868 +(% style="text-align:center" %)
1869 +[[image:12.PLC Protocol_html_b56b9da32c3caaa.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1613 1613  
1614 -This protocol is only available in PI8000 series HMI.
1615 1615  
1872 +(% style="text-align:center" %)
1873 +[[image:12.PLC Protocol_html_67cd25458b9c72a6.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1874 +
1616 1616  **HMI Settings**
1617 1617  
1618 1618  (% class="table-bordered" %)
1619 1619  |**Items**|**Settings**|**Note**
1620 -|Protocol|OPENCAN|
1621 -|Connection|CAN port|
1622 -|Baud rate|250000|
1879 +|Protocol|MODBUS RTU Master|
1880 +|Connection|RS485/RS232|
1881 +|Baud rate|2400~~187500|
1882 +|Data bit|8|
1883 +|Parity|Even/ Odd/ None|
1884 +|Stop bit|1/2|
1885 +|Station No.|0~~255|
1623 1623  
1624 -**CAN frame setting in HMI**
1887 +**Address List**
1625 1625  
1626 -Click [OpenCAN setting] button in communication setting window;
1889 +(% class="table-bordered" %)
1890 +|**Type**|**HMI address**|**MODBUS code**|**Range**
1891 +|Bit|HDX3000.0~~HDX3499.15|0|0~~7999
1892 +|Word|HDW3500~~HDW7999|4|0~~4499
1627 1627  
1628 -(% style="text-align:center" %)
1629 -[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
1894 +**Cable Wiring**
1630 1630  
1631 -Click [Add] to create a new frame;
1896 +* **RS485**
1632 1632  
1633 1633  (% style="text-align:center" %)
1634 -[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
1899 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1635 1635  
1636 -(% class="table-bordered" %)
1637 -|**No**|**Items**|**Description**
1638 -|1|Add|add a frame related to register address
1639 -|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
1640 -|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
1641 -|4|Modify|Modify the frames in frame management
1642 -|5|Copy|Copy one frame to another
1643 -|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
1644 -|7|Empty|All frames in the list are cleared
1645 -|8|Browse|Displays configuration files in XML format in IE
1646 -|9|OK|Complete the configuration of the frame and exit
1901 +(% style="text-align:center" %)
1902 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1647 1647  
1648 -Set CANBUS frame in setting windows
1904 +* **RS232**
1649 1649  
1650 1650  (% style="text-align:center" %)
1651 -[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
1907 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1652 1652  
1653 -(% class="table-bordered" %)
1654 -|**No**|(% style="width:185px" %)**Items**|(% style="width:854px" %)**Description**
1655 -|1|(% style="width:185px" %)ID|(% style="width:854px" %)Set the ID of a can frame in hexadecimal format;
1656 -|2|(% style="width:185px" %)ID assign|(% style="width:854px" %)split the ID by PF, PS, and SA;
1657 -|3|(% style="width:185px" %)Frame type|(% style="width:854px" %)Select Standard frame or Extended Frame;
1658 -|4|(% style="width:185px" %)Frame format|(% style="width:854px" %)Select between data frame and remote Frame;
1659 -|5|(% style="width:185px" %)Data|(% style="width:854px" %)Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
1660 -|6|(% style="width:185px" %)Use address|(% style="width:854px" %)(((
1661 -Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
1909 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1662 1662  
1663 -**Edit:** Set a bit or word address by its format;
1911 +== **MODBUS RTU Slave (All function)/(All function OneBaseAddress)** ==
1664 1664  
1665 -**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
1666 -)))
1667 -|(% rowspan="8" %)7|(% rowspan="8" style="width:185px" %)Data interactive configuration|(% style="width:854px" %)There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
1668 -|(% style="width:854px" %)Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
1669 -|(% style="width:854px" %)Feedback mode: feedback mode includes no response, confirm response and data response;
1670 -|(% style="width:854px" %)No response: the device or touch screen will not receive feedback;
1671 -|(% style="width:854px" %)Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
1672 -|(% style="width:854px" %)Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
1673 -|(% style="width:854px" %)response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
1674 -|(% style="width:854px" %)Response timeout: sets whether the response frame timeout;
1675 -|(% rowspan="3" %)8|(% rowspan="3" style="width:185px" %)Control address|(% style="width:854px" %)If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
1676 -|(% style="width:854px" %)Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
1677 -|(% style="width:854px" %)Manually send: a manually send tick indicates only one send;
1678 -|9|(% style="width:185px" %)Flag configuration|(% style="width:854px" %)Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
1679 -|10|(% style="width:185px" %)Note|(% style="width:854px" %)Fill the text to explain the meaning of the frame;
1680 -|11|(% style="width:185px" %)Data assign|(% style="width:854px" %)Preview the display in this table based on the address and the corresponding number of digits;
1681 -|12|(% style="width:185px" %)Current operation display|(% style="width:854px" %)Display the description of current operation;
1682 -|13|(% style="width:185px" %)Add|(% style="width:854px" %)Add a new frame;
1683 -|14|(% style="width:185px" %)Save frame|(% style="width:854px" %)Save the configured frame format;
1684 -|15|(% style="width:185px" %)Cancel|(% style="width:854px" %)Cancel the frame configuration;
1913 +Supported Series: MODBUS RTU CONTROLLER
1685 1685  
1686 -Set CAN address (Read or write operation);
1915 +HMI works as MODBUS MASTER connecting with SLAVE.
1687 1687  
1917 +The addresses in [All function] start from 0, while the addresses in [All function OneBaseAddress] start from 1 (offset 1).
1918 +
1688 1688  (% style="text-align:center" %)
1689 -[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
1920 +[[image:12.PLC Protocol_html_7236139c887defad.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1690 1690  
1691 -(% class="table-bordered" %)
1692 -|**No.**|(% style="width:207px" %)**Item**|(% style="width:829px" %)**Description**
1693 -|1|(% style="width:207px" %)Current address|(% style="width:829px" %)Displays the register type and register address set by the user in the data access interface
1694 -|(% rowspan="3" %)2|(% rowspan="3" style="width:207px" %)Trigger|(% style="width:829px" %)Two operations, "read" and "write," are based on on-screen registers
1695 -|(% style="width:829px" %)If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
1696 -|(% style="width:829px" %)If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
1697 -|(% rowspan="5" %)3|(% rowspan="3" style="width:207px" %)Data operation|(% style="width:829px" %)The read and write operations in the trigger conditions are set accordingly.
1698 -|(% style="width:829px" %)If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
1699 -|(% style="width:829px" %)If the trigger condition is a writing operation, there are two situations:(((
1700 -* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
1701 -* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
1702 -)))
1703 -|(% rowspan="2" style="width:207px" %)Position and length input format|(% style="width:829px" %)If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
1704 -|(% style="width:829px" %)If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
1705 -|4|(% style="width:207px" %)Add|(% style="width:829px" %)Add current configuration
1706 -|5|(% style="width:207px" %)Close|(% style="width:829px" %)Close the configuration window to exit
1707 1707  
1708 -**Multiple Packages Settings**
1923 +(% style="text-align:center" %)
1924 +[[image:12.PLC Protocol_html_de80207f2b495c17.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1709 1709  
1926 +
1710 1710  (% style="text-align:center" %)
1711 -[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
1928 +[[image:12.PLC Protocol_html_4e9e8eff81c7ff8b.png||data-xwiki-image-style-alignment="center" height="462" width="600" class="img-thumbnail"]]
1712 1712  
1713 -Check [Multiple packages supported] to open [Multiple package data] window, as below show.
1930 +**HMI Settings**
1714 1714  
1715 -Select Multiple package type
1932 +(% class="table-bordered" %)
1933 +|**Items**|**Settings**|**Note**
1934 +|Protocol|MODBUS RTU Slave (All function)/( All function OneBaseAddress)|
1935 +|Connection|RS485/RS232|
1936 +|Baud rate|2400~~187500|
1937 +|Data bit|8|
1938 +|Parity|Even/ Odd/ None|
1939 +|Stop bit|1/2|
1940 +|PLC station No.|0~~255|
1716 1716  
1717 -* Not Multiple packages
1718 -* J1939 Multiple packages
1719 -* Customized Multiple packages
1942 +**Address List**
1720 1720  
1721 -Click [Edit Receive data] for [Receive] settings
1944 +(% class="table-bordered" %)
1945 +|**Type**|**Address Type**|**Function code & Description**
1946 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1947 +|06 (write single register: write a binary value to a holding register)
1948 +|10 (write values to multiple addresses )
1949 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1950 +|06 (write single register: write a binary value to a holding register)
1951 +|10 (write values to multiple addresses )
1952 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1953 +|06 (write single register: write a binary value to a holding register)
1954 +|10 (write values to multiple addresses )
1955 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1956 +|10 (write values to multiple addresses )
1957 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1958 +|05 (Force a single coil to force the on/off state of a logic coil)
1959 +|0F (Write multiple bits, ie write continuously)
1960 +|(% rowspan="3" %)1|02 (Read the input state)
1961 +|05 (Force a single coil to force the on/off state of a logic coil)
1962 +|0F (Write multiple bits)
1963 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1964 +|05 (Force a single coil to force the on/off state of a logic coil)
1965 +|0F (Write multiple bits)
1966 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1967 +|0F (Write multiple bits)
1722 1722  
1723 -* Start code+ Total length (J1939)
1969 +**✎Note:**
1724 1724  
1725 -(% style="text-align:center" %)
1726 -[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1971 +* Modbus can also support getting bit from the word, which could access the address such as 100.1 and other formats.
1972 +* The function codes sent out are the same as those that read and write words.
1727 1727  
1728 -As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
1974 +**Station number for more than one slaves**
1729 1729  
1730 -* Start code + Data max length (J1939)
1976 +If there are more than one slaves connected to HMI, please set slave station number during editing address, as below shows.
1731 1731  
1732 1732  (% style="text-align:center" %)
1733 -[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1979 +[[image:12.PLC Protocol_html_31f028c6d80be344.png||data-xwiki-image-style-alignment="center" height="515" width="485" class="img-thumbnail"]]
1734 1734  
1735 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
1981 +**Cable Wiring**
1736 1736  
1737 -* Data max length (J1939)
1983 +* **RS485**
1738 1738  
1739 1739  (% style="text-align:center" %)
1740 -[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
1986 +[[image:12.PLC Protocol_html_68dfb6d383f0edd9.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1741 1741  
1742 -As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
1988 +(% style="text-align:center" %)
1989 +[[image:12.PLC Protocol_html_cbeb90cb4faaa8bc.png||data-xwiki-image-style-alignment="center" height="244" width="394" class="img-thumbnail"]]
1743 1743  
1744 -* Customized multiple package
1991 +* **RS232**
1745 1745  
1746 1746  (% style="text-align:center" %)
1747 -[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
1994 +[[image:12.PLC Protocol_html_9030ba679545793b.png||data-xwiki-image-style-alignment="center" height="241" width="387" class="img-thumbnail"]]
1748 1748  
1749 -As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
1996 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1750 1750  
1751 -Click [Edit Send data] for [Send] setting
1998 +== **MODBUS TCP Slave (All function)** ==
1752 1752  
1753 -* J1939
2000 +Supported series: MODBUS TCP controller
1754 1754  
2002 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
2003 +
1755 1755  (% style="text-align:center" %)
1756 -[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
2005 +[[image:12.PLC Protocol_html_8877cb7f39c2b607.png||data-xwiki-image-style-alignment="center" height="571" width="544" class="img-thumbnail"]]
1757 1757  
1758 -[Data] is all data to be sent.
2007 +(% style="text-align:center" %)
2008 +[[image:12.PLC Protocol_html_e7e1f06f127a9175.png||data-xwiki-image-style-alignment="center" height="426" width="553" class="img-thumbnail"]]
1759 1759  
1760 -Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
1761 1761  
1762 -* Customized multiple package
2011 +(% style="text-align:center" %)
2012 +[[image:12.PLC Protocol_html_60bbfe5de79417a6.png||data-xwiki-image-style-alignment="center" height="163" width="553" class="img-thumbnail"]]
1763 1763  
2014 +**HMI Setting**
2015 +
2016 +(% class="table-bordered" %)
2017 +|**Items**|**Settings**|**Note**
2018 +|Protocol|MODBUS TCP Slave (All function)|
2019 +|Connection|Ethernet|
2020 +|Port No.|502|
2021 +|PLC station No.|1|
2022 +
2023 +**Address List**
2024 +
2025 +(% class="table-bordered" %)
2026 +|**Type**|**Register**|**Function code & Description**
2027 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
2028 +|06 (write single register: write a binary value to a holding register)
2029 +|10 (write values to multiple addresses )
2030 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
2031 +|06 (write single register: write a binary value to a holding register)
2032 +|10 (write values to multiple addresses )
2033 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
2034 +|06 (write single register: write a binary value to a holding register)
2035 +|10 (write values to multiple addresses )
2036 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
2037 +|10 (write values to multiple addresses )
2038 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
2039 +|05 (Force a single coil to force the on/off state of a logic coil)
2040 +|0F (Write multiple bits, ie write continuously)
2041 +|(% rowspan="3" %)1|02 (Read the input state)
2042 +|05 (Force a single coil to force the on/off state of a logic coil)
2043 +|0F (Write multiple bits)
2044 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
2045 +|05 (Force a single coil to force the on/off state of a logic coil)
2046 +|0F (Write multiple bits)
2047 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
2048 +|0F (Write multiple bits)
2049 +
2050 +**Communication Settings**
2051 +
2052 +Enable HMI Ethernet in [Project Settings];
2053 +
1764 1764  (% style="text-align:center" %)
1765 -[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
2055 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1766 1766  
1767 -[Data] is all data to be sent.
2057 +Set PLC IP in [Device IP] settings;
1768 1768  
1769 -As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
2059 +(% style="text-align:center" %)
2060 +[[image:12.PLC Protocol_html_4bd3cc8348adecf8.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
1770 1770  
1771 1771  **Cable Wiring**
1772 1772  
1773 1773  (% style="text-align:center" %)
1774 -[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
2065 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
1775 1775  
1776 -**✎Note:** The address interval between each frame need to be more than a word address;
1777 -
1778 1778  = **SHIMADEN** =
1779 1779  
1780 1780  == **FP23** ==
... ... @@ -1949,559 +1949,6 @@
1949 1949  
1950 1950  **✎Note:** COM3 only available in PI8000/PI9000 series.
1951 1951  
1952 -= **Siemens** =
1953 -
1954 -== **S7-200 Smart Ethernet** ==
1955 -
1956 -Supported Series: Siemens S7-200 SMART Series Ethernet Module.
1957 -
1958 -Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
1959 -
1960 -**HMI Setting**
1961 -
1962 -(% class="table-bordered" %)
1963 -|**Items**|**Settings**|**Note**
1964 -|Protocol|Simens S7-200 Smart Ethernet|
1965 -|Connection|Ethernet|
1966 -|Port No.|102|
1967 -|PLC station No.|2|
1968 -
1969 -**Address List**
1970 -
1971 -(% class="table-bordered" %)
1972 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1973 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
1974 -|Q|Q|Q ddddd.o|0.0~~99999.7|
1975 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
1976 -|V|V|V ddddd.o|0.0~~99999.7|
1977 -|M|M|M ddddd.o|0.0~~99999.7|
1978 -|SM|SM|ddddd.o|0.0~~99999.7|
1979 -|S|S|ddddd.o|0.0~~99999.7|Read only
1980 -|T|T|ddddd|0~~99999|Timer state, read only
1981 -|C|C|ddddd|0~~99999|Counter state, read only
1982 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
1983 -|Q|QW|QW ddddd|0~~99999|
1984 -|AI|AIW|AIW ddddd|0~~99999|
1985 -|AQ|VB|VB ddddd|0~~99999|
1986 -|V|VW|VW ddddd|0~~99998|(((
1987 -VW0=VB (0~~1)
1988 -
1989 -VW2=VB (2~~3)
1990 -
1991 -Address value is a multiple of 2
1992 -)))
1993 -|V|VD|VD ddddd|0~~99998|(((
1994 -VD0=VB (0~~3)
1995 -
1996 -VD2=VB (4~~7)
1997 -
1998 -Address value is a multiple of 4
1999 -)))
2000 -|M|MB|MB ddddd|0~~99999|
2001 -|M|MW|MW ddddd|0~~99999|(((
2002 -MW0=MB(0~~1)
2003 -
2004 -MW2=MB(2~~3)
2005 -
2006 -Address value is a multiple of 2
2007 -)))
2008 -|M|MD|MD ddddd|0~~99999|(((
2009 -MD0=MB(0~~3)
2010 -
2011 -MD4=MB(4~~7)
2012 -
2013 -Address value is a multiple of 4
2014 -)))
2015 -|T|TW|TW ddddd|0~~99999|Value of timer
2016 -|C|CW|CW ddddd|0~~99999|Value of counter
2017 -|W|SW|SW ddddd|0~~99999|
2018 -
2019 -**Communication Settings**
2020 -
2021 -Enable HMI Ethernet in [Project Settings];
2022 -
2023 -(% style="text-align:center" %)
2024 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2025 -
2026 -Set PLC IP in [Device IP] settings;
2027 -
2028 -(% style="text-align:center" %)
2029 -[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2030 -
2031 -* PLC IP Address: PLC IP
2032 -* PLC pot No.: 102(fixed)
2033 -* Network:TCP_Client_2N(fixed)
2034 -
2035 -(% style="text-align:center" %)
2036 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
2037 -
2038 -* Wait timeout: depend on actual network situation (more than 1500 ms)
2039 -
2040 -**Cable Wiring**
2041 -
2042 -(% style="text-align:center" %)
2043 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2044 -
2045 -== **S7-300 Ethernet** ==
2046 -
2047 -Supported Series: Siemens S7-300 series PLC
2048 -
2049 -**HMI Setting**
2050 -
2051 -(% class="table-bordered" %)
2052 -|**Items**|**Settings**|**Note**
2053 -|Protocol|Simens S7-300 Ethernet|
2054 -|Connection|Ethernet|
2055 -|Port No.|102|
2056 -|PLC station No.|2|Need to be same as the PLC setting
2057 -
2058 -**Address List**
2059 -
2060 -(% class="table-bordered" %)
2061 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2062 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
2063 -|Q|Q|Q ddddd.o|0.0~~99999.7|
2064 -|M|M|M ddddd.o|0.0~~99999.7|
2065 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
2066 -nn: block number;
2067 -
2068 -dddd: address;
2069 -)))
2070 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
2071 -|Q|QW|QW ddddd|0~~99999|
2072 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
2073 -|MW|MW ddddd|0~~99999|(((
2074 -MW0=MB(0~~1)
2075 -
2076 -MW2=MB(2~~3)
2077 -
2078 -Address value is a multiple of 2
2079 -)))
2080 -|MD|MD ddddd|0~~99999|(((
2081 -MD0=MB(0~~3)
2082 -
2083 -MD4=MB(4~~7)
2084 -
2085 -Address value is a multiple of 4
2086 -)))
2087 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
2088 -nn: block number;
2089 -
2090 -dddd: address
2091 -)))
2092 -|DBxDBW|DBxDBW nndddd|0~~99999999
2093 -|DBxDBD|DBxDBD nndddd|0~~99999999
2094 -
2095 -**Communication Settings**
2096 -
2097 -Enable HMI Ethernet in [Project Settings];
2098 -
2099 -(% style="text-align:center" %)
2100 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2101 -
2102 -Set PLC IP in [Device IP] settings;
2103 -
2104 -(% style="text-align:center" %)
2105 -[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
2106 -
2107 -* PLC IP Address: PLC IP
2108 -* PLC pot No.: 102(fixed)
2109 -* Network:TCP_Client_2N(fixed)
2110 -
2111 -(% style="text-align:center" %)
2112 -[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
2113 -
2114 -* Wait timeout: depend on actual network situation (more than 1500 ms)
2115 -
2116 -**Cable Wiring**
2117 -
2118 -(% style="text-align:center" %)
2119 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2120 -
2121 -== **S7-1200 Ethernet** ==
2122 -
2123 -Supported Series: Siemens S7-1200
2124 -
2125 -**HMI Setting**
2126 -
2127 -(% class="table-bordered" %)
2128 -|**Items**|**Settings**|**Note**
2129 -|Protocol|Siemens S7-1200|
2130 -|Connection|Ethernet|
2131 -|Port No.|102|
2132 -|PLC station No.|2|
2133 -
2134 -**Address List**
2135 -
2136 -(% class="table-bordered" %)
2137 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2138 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
2139 -d:0~-~-9999
2140 -
2141 -o:0-7
2142 -)))|
2143 -|Q|Q|Q d.o|(((
2144 -d:0~-~-9999
2145 -
2146 -o:0-7
2147 -)))|
2148 -|M|M|M d.o|(((
2149 -d:0~-~-9999
2150 -
2151 -o:0-7
2152 -)))|
2153 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2154 -nn:0-9999,
2155 -
2156 -dddd:0-9999,
2157 -
2158 -o:0-7
2159 -)))|(((
2160 -nn:DB No.
2161 -
2162 -dddd:address value
2163 -
2164 -o: digit address
2165 -)))
2166 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2167 -|M|MW|MW d|d:0-99999|(((
2168 -MW0=MB(0~~1)
2169 -
2170 -MW2=MB(2~~3)
2171 -
2172 -Address value is a multiple of 2
2173 -)))
2174 -|M|MD|MD d|d:0-99999|(((
2175 -MD0=MB(0~~3)
2176 -
2177 -MD4=MB(4~~7)
2178 -
2179 -Address value is a multiple of 4
2180 -)))
2181 -|I|IW|IW d|d:0-99999|
2182 -|Q|QW|QW d|d:0-99999|
2183 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2184 -nn:0-9999
2185 -
2186 -dddd:0-9999
2187 -)))|(((
2188 -nn:DB No.
2189 -
2190 -dddd:address value
2191 -)))
2192 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2193 -nn:0-9999
2194 -
2195 -dddd:0-9999
2196 -)))|(((
2197 -nn:DB No.
2198 -
2199 -dddd:address value
2200 -
2201 -Address value is a multiple of 2
2202 -)))
2203 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2204 -nn:0-9999
2205 -
2206 -dddd:0-9999
2207 -)))|(((
2208 -nn:DB No.
2209 -
2210 -dddd:address value
2211 -
2212 -Address value is a multiple of 4
2213 -)))
2214 -
2215 -**Communication Settings**
2216 -
2217 -Enable HMI Ethernet in [Project Settings];
2218 -
2219 -(% style="text-align:center" %)
2220 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2221 -
2222 -Set PLC IP in [Device IP] settings;
2223 -
2224 -(% style="text-align:center" %)
2225 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2226 -
2227 -**✎Note:**
2228 -
2229 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2230 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2231 -
2232 -**PLC Settings**
2233 -
2234 -Add BD
2235 -
2236 -* Please uncheck [Symbolic access only] option;
2237 -
2238 -(% style="text-align:center" %)
2239 -[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
2240 -
2241 -Address settings, using BD2 as example.
2242 -
2243 -* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
2244 -* 2 represent DB block number
2245 -* xxxx represent address
2246 -
2247 -**Such as:**
2248 -
2249 -* DBxDBB20000 = DB2.DBB0
2250 -* DBxDBW20004 = DB2.DBW4
2251 -
2252 -(% style="text-align:center" %)
2253 -[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
2254 -
2255 -**How to connect with S7-1200 Firmware V4.0**
2256 -
2257 -PLC configuration
2258 -
2259 -* Double click [device configuration] in Siemens via software
2260 -* Double click [protection] to enter protection configuration screen
2261 -
2262 -(% style="text-align:center" %)
2263 -[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
2264 -
2265 -* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
2266 -
2267 -(% style="text-align:center" %)
2268 -[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
2269 -
2270 -DB settings
2271 -
2272 -* Right click [DB], select [properties]
2273 -* Uncheck [optimized block access]
2274 -
2275 -**Cable Wiring**
2276 -
2277 -(% style="text-align:center" %)
2278 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2279 -
2280 -== **LOGO Ethernet** ==
2281 -
2282 -Supported Series: Siemens Logo 0BA0 series
2283 -
2284 -**HMI Settings**
2285 -
2286 -(% class="table-bordered" %)
2287 -|**Items**|**Settings**|**Note**
2288 -|Protocol|Siemens LOGO|
2289 -|Connection|Ethernet|
2290 -|Port No.|102|
2291 -|PLC station No.|2|
2292 -
2293 -**Address List**
2294 -
2295 -(% class="table-bordered" %)
2296 -|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
2297 -|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
2298 -|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
2299 -|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
2300 -|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
2301 -|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
2302 -|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
2303 -|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
2304 -|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
2305 -|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
2306 -|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
2307 -|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
2308 -|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
2309 -|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
2310 -|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
2311 -|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
2312 -
2313 -**PLC Settings in LOGO Software:**
2314 -
2315 -Click [Tools]~-~-[Ethernet Connections],shown as below.
2316 -
2317 -(% style="text-align:center" %)
2318 -[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
2319 -
2320 -Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
2321 -
2322 -(% style="text-align:center" %)
2323 -[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
2324 -
2325 -**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
2326 -
2327 -(% style="text-align:center" %)
2328 -[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
2329 -
2330 -**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
2331 -
2332 -(% style="text-align:center" %)
2333 -[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
2334 -
2335 -
2336 -(% style="text-align:center" %)
2337 -[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
2338 -
2339 -
2340 -**HMI Communication Settings**
2341 -
2342 -Set PLC IP in [Device IP] settings;
2343 -
2344 -(% style="text-align:center" %)
2345 -[[image:SiemensLOGODeviceIP.png]]
2346 -
2347 -Enable HMI Ethernet in [Project Settings];
2348 -
2349 -(% style="text-align:center" %)
2350 -[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
2351 -
2352 -TSAP setting
2353 -
2354 -* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
2355 -* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
2356 -* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
2357 -
2358 -**✎Note:**
2359 -
2360 -* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
2361 -
2362 -(% style="text-align:center" %)
2363 -[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
2364 -
2365 -
2366 -* AI word address and Ibit address are read-only and cannot be written on HMI.
2367 -* VW address should be even number.such as VW0, VW2, VW4...
2368 -* VD address it takes two VW addresses.such as VD0,VD4,VD8...
2369 -* Written value of RTC cannot exceed 255.
2370 -
2371 -**Cable Wiring**
2372 -
2373 -(% style="text-align:center" %)
2374 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2375 -
2376 -== **S7-XXX Ethernet** ==
2377 -
2378 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
2379 -
2380 -**HMI Setting**
2381 -
2382 -(% class="table-bordered" style="width:823px" %)
2383 -|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
2384 -|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
2385 -|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
2386 -|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
2387 -|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
2388 -|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
2389 -
2390 -Slot from TIA Portal is equal to Device No. of PIStudio
2391 -
2392 -Rack from TIA Portal is equal to HMI No. of PIStudio
2393 -
2394 -(% style="text-align:center" %)
2395 -[[image:S7-XXXCommunication Settings.png]]
2396 -
2397 -(% style="text-align:center" %)
2398 -[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
2399 -
2400 -**Address List**
2401 -
2402 -(% class="table-bordered" %)
2403 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
2404 -|(% rowspan="4" %)Bit|I|I|M d.o|(((
2405 -d:0~-~-9999
2406 -
2407 -o:0-7
2408 -)))|
2409 -|Q|Q|Q d.o|(((
2410 -d:0~-~-9999
2411 -
2412 -o:0-7
2413 -)))|
2414 -|M|M|M d.o|(((
2415 -d:0~-~-9999
2416 -
2417 -o:0-7
2418 -)))|
2419 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
2420 -nn:0-9999,
2421 -
2422 -dddd:0-9999,
2423 -
2424 -o:0-7
2425 -)))|(((
2426 -nn:DB No.
2427 -
2428 -dddd:address value
2429 -
2430 -o: digit address
2431 -)))
2432 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
2433 -|M|MW|MW d|d:0-99999|(((
2434 -MW0=MB(0~~1)
2435 -
2436 -MW2=MB(2~~3)
2437 -
2438 -Address value is a multiple of 2
2439 -)))
2440 -|M|MD|MD d|d:0-99999|(((
2441 -MD0=MB(0~~3)
2442 -
2443 -MD4=MB(4~~7)
2444 -
2445 -Address value is a multiple of 4
2446 -)))
2447 -|I|IW|IW d|d:0-99999|
2448 -|Q|QW|QW d|d:0-99999|
2449 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
2450 -nn:0-9999
2451 -
2452 -dddd:0-9999
2453 -)))|(((
2454 -nn:DB No.
2455 -
2456 -dddd:address value
2457 -)))
2458 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
2459 -nn:0-9999
2460 -
2461 -dddd:0-9999
2462 -)))|(((
2463 -nn:DB No.
2464 -
2465 -dddd:address value
2466 -
2467 -Address value is a multiple of 2
2468 -)))
2469 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
2470 -nn:0-9999
2471 -
2472 -dddd:0-9999
2473 -)))|(((
2474 -nn:DB No.
2475 -
2476 -dddd:address value
2477 -
2478 -Address value is a multiple of 4
2479 -)))
2480 -
2481 -**Communication Settings**
2482 -
2483 -Enable HMI Ethernet in [Project Settings];
2484 -
2485 -(% style="text-align:center" %)
2486 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
2487 -
2488 -Set PLC IP in [Device IP] settings;
2489 -
2490 -(% style="text-align:center" %)
2491 -[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2492 -
2493 -**✎Note:**
2494 -
2495 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
2496 -* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
2497 -
2498 -**Cable Wiring**
2499 -
2500 -{{id name="OLE_LINK8"/}}
2501 -
2502 -(% style="text-align:center" %)
2503 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2504 -
2505 2505  = **User Defined Protocol** =
2506 2506  
2507 2507  If the device does not support MODBUS standard, and the protocol is not list in PIStudio, then user can define the protocol by following instruction to realize simply communication functions like sending and receiving commands.
... ... @@ -2646,8 +2646,6 @@
2646 2646  
2647 2647  **✎Note:** COM3 only available in PI8000/PI9000 series.
2648 2648  
2649 -= =
2650 -
2651 2651  = **Printer** =
2652 2652  
2653 2653  == **TSPL label printer** ==
... ... @@ -2848,3 +2848,449 @@
2848 2848  
2849 2849  (% style="text-align:center" %)
2850 2850  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2585 +
2586 += **Barcode Scanner** =
2587 +
2588 +Supported: DELI 14880 barcode scanner
2589 +
2590 +**HMI Setting**
2591 +
2592 +|**Items**|**Settings**|**Note**
2593 +|Protocol|Barcode Scanner|
2594 +|Connection|USB|
2595 +
2596 +**Operating Procedures**
2597 +
2598 +Select [Barcode Scanner];
2599 +
2600 +(% style="text-align:center" %)
2601 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2602 +
2603 +Set address for receiving;
2604 +
2605 +Set correct length;
2606 +
2607 +(% style="text-align:center" %)
2608 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2609 +
2610 +**✎Note:**
2611 +
2612 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2613 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2614 +* Recommended model: DELI 14880 barcode scanner;
2615 +
2616 += **Hitachi EHV Series (Ethernet)** =
2617 +
2618 +Supported series: Hitachi EHV series
2619 +
2620 +**HMI Settings**
2621 +
2622 +(% class="table-bordered" %)
2623 +|**Items**|**Settings**|**Note**
2624 +|Protocol|Hitachi EHV series|
2625 +|Connection|Ethernet|
2626 +|Port No.|3004~~3007|
2627 +
2628 +**Address List**
2629 +
2630 +(% class="table-bordered" %)
2631 +|**Type**|**Register**|**Range**|**Format**|**Note**
2632 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2633 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2634 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2635 +H1H2H3H4 Module main number
2636 +
2637 +H1: Remote number
2638 +
2639 +H2: Unit number
2640 +
2641 +H3: Slot number
2642 +
2643 +H4: Word number of Module
2644 +
2645 +H Sub number of Module
2646 +
2647 +For example:X21.3
2648 +
2649 +Slot number 2
2650 +
2651 +Word number of module is 1
2652 +
2653 +Bit number of module is 3
2654 +
2655 +Remote number and unit number are 0
2656 +)))
2657 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2658 +|R|0 – FF.f (Hex)|R HH.h|
2659 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2660 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2661 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2662 +H1H2H3H4 Module main number
2663 +
2664 +H1: Remote number
2665 +
2666 +H2: Unit number
2667 +
2668 +H3: Slot number
2669 +
2670 +H4: Word number of module
2671 +
2672 +For example:WX21
2673 +
2674 +Word number of module is 1
2675 +
2676 +Slot number is 2
2677 +
2678 +Remote number and unit number are 0
2679 +)))
2680 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2681 +|WR|0 – FFFF (Hex)|WR HHHH|
2682 +|WL|0 - 73FF (Hex)|WL HHHH|
2683 +|TC|0 - 2559|TC DDDD|
2684 +
2685 +**Communication settings in HMI**
2686 +
2687 +Enable HMI Ethernet in [Project Settings];
2688 +
2689 +(% style="text-align:center" %)
2690 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2691 +
2692 +Set PLC IP in [Device IP] settings;
2693 +
2694 +(% style="text-align:center" %)
2695 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2696 +
2697 +**PLC Configuration**
2698 +
2699 +Connect with PLC, select[Online mode];
2700 +
2701 +(% style="text-align:center" %)
2702 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2703 +
2704 +Set IP address, it is the same LAN parameters with HMI;
2705 +
2706 +(% style="text-align:center" %)
2707 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2708 +
2709 +3) Save PLC communication parameter, and restart PLC
2710 +
2711 +**PLC Monitor Mode**
2712 +
2713 +Connect with PLC and choose to “online” mode
2714 +
2715 +(% style="text-align:center" %)
2716 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2717 +
2718 +Open I/O monitor sheet1
2719 +
2720 +(% style="text-align:center" %)
2721 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2722 +
2723 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2724 +
2725 +(% style="text-align:center" %)
2726 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2727 +
2728 +Enter the register address, click OK to view the value of the register.
2729 +
2730 +(% style="text-align:center" %)
2731 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2732 +
2733 +(% style="text-align:center" %)
2734 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2735 +
2736 +**✎Note:**
2737 +
2738 +* Both word registers and bit registers support even continuous read/write functions;
2739 +* The range of registers is based on the specific PLC type;
2740 +
2741 +**Cable Wiring**
2742 +
2743 +(% style="text-align:center" %)
2744 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2745 +
2746 += **IEC60870-5 104 Client** =
2747 +
2748 +**HMI Setting**
2749 +
2750 +(% class="table-bordered" %)
2751 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2752 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2753 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2754 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2755 +
2756 +**Address List**
2757 +
2758 +(% class="table-bordered" %)
2759 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2760 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2761 +|(% style="width:461px" %)SCNA|0~~16777215.7
2762 +|(% style="width:461px" %)DPTB|0~~16777215.7
2763 +|(% style="width:461px" %)DCNA|0~~16777215.7
2764 +|(% style="width:461px" %)METF|0~~16777215.7
2765 +|(% style="width:461px" %)SENC|0~~16777215.7
2766 +|(% style="width:461px" %)SENA|0~~16777215.7
2767 +|(% style="width:461px" %)MENA|0~~16777215.7
2768 +|(% style="width:461px" %)METD|0~~16777215.7
2769 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2770 +|(% style="width:461px" %)SCNA|0~~16777215
2771 +|(% style="width:461px" %)DPTB|0~~16777215
2772 +|(% style="width:461px" %)DCNA|0~~16777215
2773 +|(% style="width:461px" %)SENA|0~~16777215
2774 +|(% style="width:461px" %)MENA|0~~16777215
2775 +|(% style="width:461px" %)METD|0~~16777215
2776 +|(% style="width:461px" %)INRO|0~~16777215
2777 +|(% style="width:461px" %)TIMESYN|0~~16777215
2778 +|(% style="width:461px" %)TIMEZ|0~~16777215
2779 +|(% style="width:461px" %)NTP|0~~16777215
2780 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2781 +|(% style="width:461px" %)SENC|0~~16777215
2782 +
2783 +**Address Configuration**
2784 +
2785 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2786 +
2787 +(% style="text-align:center" %)
2788 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2789 +
2790 +(% style="text-align:center" %)
2791 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2792 +
2793 +Extended tag name
2794 +
2795 +Address range for the extended tag.
2796 +
2797 +**Communication Settings**
2798 +
2799 +Enable HMI Ethernet in [Project Settings];
2800 +
2801 +(% style="text-align:center" %)
2802 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2803 +
2804 +Set PLC IP in [Device IP] settings;
2805 +
2806 +(% style="text-align:center" %)
2807 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2808 +
2809 +**Cable Wiring**
2810 +
2811 +(% style="text-align:center" %)
2812 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2813 +
2814 += **LG XGK FEnet Ethernet** =
2815 +
2816 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2817 +
2818 +**HMI Settings**
2819 +
2820 +(% class="table-bordered" %)
2821 +|**Items**|**Settings**|**Note**
2822 +|Protocol|LG XGK FEnet(Ethernet)|
2823 +|Connection|Ethernet|
2824 +|Port No.|2004|
2825 +
2826 +**Address List**
2827 +
2828 +(% class="table-bordered" %)
2829 +|**Type**|**Register**|**Range**|**Format**|**Note**
2830 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2831 +|M|0~~2047|M d|
2832 +|K|0~~2047|K d|
2833 +|F|0~~2047|F d|
2834 +|T|0~~2047|T d|
2835 +|C|0~~2047|C d|
2836 +|Z|0~~127|Z d|
2837 +|S|0~~127|S d|
2838 +|L|0~~11263|L d|
2839 +|N|0~~21503|N d|
2840 +|D|0~~32767|D d|
2841 +|R|0~~32767|R d|
2842 +|ZR|0~~65535|ZR d|
2843 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2844 +
2845 +**✎Note:**
2846 +
2847 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2848 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2849 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2850 +
2851 +**Communication settings in HMI**
2852 +
2853 +Enable HMI Ethernet in [Project Settings];
2854 +
2855 +(% style="text-align:center" %)
2856 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2857 +
2858 +Set PLC IP in [Device IP] settings;
2859 +
2860 +(% style="text-align:center" %)
2861 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2862 +
2863 +**Cable Wiring**
2864 +
2865 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2866 +
2867 +
2868 += **OpenCAN** =
2869 +
2870 +OpenCan is based on CAN2.0 standard; OpenCAN protocols that could be configured autonomously to accept and send frames.
2871 +
2872 +This protocol is only available in PI8000 series HMI.
2873 +
2874 +**HMI Settings**
2875 +
2876 +|**Items**|**Settings**|**Note**
2877 +|Protocol|OPENCAN|
2878 +|Connection|CAN port|
2879 +|Baud rate|250000|
2880 +
2881 +**CAN frame setting in HMI**
2882 +
2883 +Click [OpenCAN setting] button in communication setting window;
2884 +
2885 +(% style="text-align:center" %)
2886 +[[image:12.PLC Protocol_html_e866b9e56e19785d.png||data-xwiki-image-style-alignment="center" height="503" width="600" class="img-thumbnail"]]
2887 +
2888 +Click [Add] to create a new frame;
2889 +
2890 +(% style="text-align:center" %)
2891 +[[image:12.PLC Protocol_html_3a6f4e2141763c8f.png||data-xwiki-image-style-alignment="center" height="315" width="600" class="img-thumbnail"]]
2892 +
2893 +|**No**|**Items**|**Description**
2894 +|1|Add|add a frame related to register address
2895 +|2|Insert|Select the position where you want to insert a frame, and click [Insert frame] to add a new frame in front of the current frame position
2896 +|3|Frame manager|This list shows some of the main parameters for each frame that the user adds
2897 +|4|Modify|Modify the frames in frame management
2898 +|5|Copy|Copy one frame to another
2899 +|6|Delete|Remove the selected frames from the list by modifying the frames in frame management. If no frames are selected in the list, the first frame is deleted.
2900 +|7|Empty|All frames in the list are cleared
2901 +|8|Browse|Displays configuration files in XML format in IE
2902 +|9|OK|Complete the configuration of the frame and exit
2903 +
2904 +Set CANBUS frame in setting windows
2905 +
2906 +(% style="text-align:center" %)
2907 +[[image:12.PLC Protocol_html_7c83130820321ef.png||data-xwiki-image-style-alignment="center" height="507" width="600" class="img-thumbnail"]]
2908 +
2909 +|**No**|**Items**|**Description**
2910 +|1|ID|Set the ID of a can frame in hexadecimal format;
2911 +|2|ID assign|split the ID by PF, PS, and SA;
2912 +|3|Frame type|Select Standard frame or Extended Frame;
2913 +|4|Frame format|Select between data frame and remote Frame;
2914 +|5|Data|Set the data part of CAN frame, with two Numbers representing a hexadecimal number and Spaces spaced; Maximum support of 8 bytes is defined according to CAN message;
2915 +|6|Use address|(((
2916 +Set the register address related to the CAN frame, which corresponds to the register address set on the main state one by one. The data obtained from the address is assigned continuously;
2917 +
2918 +**Edit:** Set a bit or word address by its format;
2919 +
2920 +**Option: **Set address options related to frame, enter “register address option” interface, specifically browse the following “register address option” interface;
2921 +)))
2922 +|(% rowspan="8" %)7|(% rowspan="8" %)Data interactive configuration|There are two interactive modes of the touch screen. One is that the touch screen actively sends frames, and the device receives and processes and feeds back. The other, on the contrary, passively receives frames from the device for processing and feedback;
2923 +|Send after receiving: if this item is selected, the interaction of the touch screen will act as a passive party, and the touch screen will receive the CAN frame first and send feedback. Unchecked items interact in the opposite way;
2924 +|Feedback mode: feedback mode includes no response, confirm response and data response;
2925 +|No response: the device or touch screen will not receive feedback;
2926 +|Confirm response: the device or the touch screen will receive feedback with confirmation, which could be used to compare the data parts. If this function is used, the 20 addresses before and after this address should not be used. All addresses of cata10-cata30 could not be used with the reply confirmation function of cata20;
2927 +|Data response: the device or touch screen will receive feedback with data, and the data to be separated from the feedback frame should be set to store in the register address;
2928 +|response ID: if the address wants to receive data on a frame with a different ID, set this, check "different from sender", and enter a different ID in the following input box. Without this setting, the screen will receive and process a frame with the same ID as the sender;
2929 +|Response timeout: sets whether the response frame timeout;
2930 +|(% rowspan="3" %)8|(% rowspan="3" %)Control address|If ticked, enable sending when the value of the corresponding control bit number (address) is non-0.
2931 +|Control bit: CtrlBit register range 0~~255, if the control bit is ON, can instruction will run normally. Otherwise, it doesn't run;
2932 +|Manually send: a manually send tick indicates only one send;
2933 +|9|Flag configuration|Communication control for each frame. Display OFF when communication is normal, and ON when communication is abnormal;
2934 +|10|Note|Fill the text to explain the meaning of the frame;
2935 +|11|Data assign|Preview the display in this table based on the address and the corresponding number of digits;
2936 +|12|Current operation display|Display the description of current operation;
2937 +|13|Add|Add a new frame;
2938 +|14|Save frame|Save the configured frame format;
2939 +|15|Cancel|Cancel the frame configuration;
2940 +
2941 +Set CAN address (Read or write operation);
2942 +
2943 +(% style="text-align:center" %)
2944 +[[image:12.PLC Protocol_html_7e9f9b25eb6ae8ce.png||data-xwiki-image-style-alignment="center" height="446" width="600" class="img-thumbnail"]]
2945 +
2946 +|**No.**|**Item**|**Description**
2947 +|1|Current address|Displays the register type and register address set by the user in the data access interface
2948 +|(% rowspan="3" %)2|(% rowspan="3" %)Trigger|Two operations, "read" and "write," are based on on-screen registers
2949 +|If "read" is selected, the register address is reading device data in a manner of sending frames set by the user in a loop.
2950 +|If "write" is selected, the screen data of the register address will be written into the device. The writing mode is that the user makes a write operation on the screen, which will trigger the sending of a frame set by the user.
2951 +|(% rowspan="5" %)3|(% rowspan="3" %)Data operation|The read and write operations in the trigger conditions are set accordingly.
2952 +|If the trigger condition is a read operation, this section needs to set the position and length of the data to be obtained at the current address in the frame.
2953 +|If the trigger condition is a writing operation, there are two situations:(((
2954 +* If the "add writing data to the frame" option is not selected, the frame set by the user will be sent directly when the user writes on the screen.
2955 +* Select the "add the written data to the frame" option, and when the user writes on the screen, the program will insert the data in the frame set by the user and send the written data to the frame set by the user according to the data insertion position and length set by the user.
2956 +)))
2957 +|(% rowspan="2" %)Position and length input format|If the register type is a bit address, the decimal point is required to represent the bits in the byte. For example, 1.1 represents the first bit of the first byte of 8 bytes in the data frame, and the length is in bits, and so on.
2958 +|If the register type is word address, the integer only needs to represent the byte, such as 1, which represents the first byte of 8-byte data in the data frame, and the unit of length is byte, and so on.
2959 +|4|Add|Add current configuration
2960 +|5|Close|Close the configuration window to exit
2961 +
2962 +**Multiple Packages Settings**
2963 +
2964 +(% style="text-align:center" %)
2965 +[[image:12.PLC Protocol_html_107e0f6b1a90afff.png||data-xwiki-image-style-alignment="center" height="341" width="600" class="img-thumbnail"]]
2966 +
2967 +Check [Multiple packages supported] to open [Multiple package data] window, as below show.
2968 +
2969 +Select Multiple package type
2970 +
2971 +* Not Multiple packages
2972 +* J1939 Multiple packages
2973 +* Customized Multiple packages
2974 +
2975 +Click [Edit Receive data] for [Receive] settings
2976 +
2977 +* Start code+ Total length (J1939)
2978 +
2979 +(% style="text-align:center" %)
2980 +[[image:12.PLC Protocol_html_3c360c6b5aca51bf.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2981 +
2982 +As set above set, J1939 command is received by the HMI, only when its length is 25 bytes, and the start code is 0x57, 0x1B;
2983 +
2984 +* Start code + Data max length (J1939)
2985 +
2986 +(% style="text-align:center" %)
2987 +[[image:12.PLC Protocol_html_74496b2a68cfcdde.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2988 +
2989 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes, and the start code is 0x57, 0x1B;
2990 +
2991 +* Data max length (J1939)
2992 +
2993 +(% style="text-align:center" %)
2994 +[[image:12.PLC Protocol_html_98cea3e7cbd8f05d.png||data-xwiki-image-style-alignment="center" height="340" width="426" class="img-thumbnail"]]
2995 +
2996 +As set above set, J1939 command is received by the HMI, only when its length less than 50 bytes.
2997 +
2998 +* Customized multiple package
2999 +
3000 +(% style="text-align:center" %)
3001 +[[image:12.PLC Protocol_html_4635bbe4d7999db0.png||data-xwiki-image-style-alignment="center" height="395" width="367" class="img-thumbnail"]]
3002 +
3003 +As set above, It is received by the HMI, when the first frame starts with 0X57 0X1B, and the sum of the data lengths of multiple frames is equal to 79 bytes.
3004 +
3005 +Click [Edit Send data] for [Send] setting
3006 +
3007 +* J1939
3008 +
3009 +(% style="text-align:center" %)
3010 +[[image:12.PLC Protocol_html_a4769e44331ca732.png||data-xwiki-image-style-alignment="center" height="280" width="463" class="img-thumbnail"]]
3011 +
3012 +[Data] is all data to be sent.
3013 +
3014 +Since the frame of the J1939 frame contains the number of the data packet, so the data sent is: the first byte (number) + 7 bytes of data. If it is less than 7 bytes, it is sent in the actual number of bytes.
3015 +
3016 +* Customized multiple package
3017 +
3018 +(% style="text-align:center" %)
3019 +[[image:12.PLC Protocol_html_78546f765d6f3deb.png||data-xwiki-image-style-alignment="center" height="280" width="463"]]
3020 +
3021 +[Data] is all data to be sent.
3022 +
3023 +As set above, fist frame length is 2 bytes, and others are sent with 6 bytes for every frame, if the last frame is less than 6 bytes, send according to the actual length.
3024 +
3025 +**Cable Wiring**
3026 +
3027 +(% style="text-align:center" %)
3028 +[[image:12.PLC Protocol_html_fccede84efcbdc22.png||data-xwiki-image-style-alignment="center" height="111" width="391" class="img-thumbnail"]]
3029 +
3030 +**✎Note:** The address interval between each frame need to be more than a word address;
image-20220829151746-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.1 KB
Content
image-20220829151848-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +15.0 KB
Content
image-20220829152016-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.2 KB
Content
image-20220829152042-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +17.0 KB
Content
image-20220829152102-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +16.3 KB
Content
image-20220829152327-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +42.5 KB
Content
image-20220829152610-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +55.5 KB
Content
image-20220829155452-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.1 KB
Content
image-20220829162116-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.4 KB
Content
image-20220830094600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +40.4 KB
Content
image-20220830094657-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.4 KB
Content
image-20220830094929-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.4 KB
Content
image-20220830095131-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +25.7 KB
Content
image-20220830140537-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +35.2 KB
Content
image-20220830140629-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content
image-20220830141138-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +82.9 KB
Content