Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 66.1
edited by Ben
on 2022/08/29 14:06
Change comment: There is no comment for this version
To version 64.1
edited by Ben
on 2022/08/29 13:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,59 +87,6 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 -
91 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 -
93 -**HMI Settings**
94 -
95 -(% class="table-bordered" %)
96 -|**Item**|**Settings**|**Note**
97 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
98 -|Connection|RS422/RS485|
99 -|Baud rate|9600|
100 -|Data bit|7|
101 -|Parity|EVEN|
102 -|Stop bit|1|
103 -|PLC station No.|1|
104 -
105 -**Address List**
106 -
107 -(% class="table-bordered" %)
108 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
109 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
110 -|Y|Y|Y o|0~~303237|
111 -|M|M|M d|0~~99999|
112 -|T|T|T d|0~~99999|
113 -|C|C|C d|0~~99999|
114 -|S|S|S d|0~~99999|
115 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
116 -|Y|Y|Y o|0~~303237|
117 -|M|M|M d|0~~99999|
118 -|T|T|T d|0~~99999|
119 -|C|C|C d|0~~199|
120 -|D|D|D d|0~~7999|
121 -|S|S|S d|0~~99999|
122 -|SD|SD|SD d|8000~~9999|
123 -
124 -**Cable Wiring**
125 -
126 -* **RS485**
127 -
128 -(% style="text-align:center" %)
129 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
130 -
131 -* **RS422**
132 -
133 -(% style="text-align:center" %)
134 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
135 -
136 -**✎Note:**
137 -
138 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
139 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
140 -
141 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 -
143 143  == HMI settings ==
144 144  
145 145  **Download PIStudio Software**
... ... @@ -314,8 +314,63 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **HMI and Wecon LX5V serial communication** =
264 += **WECON PLC** =
318 318  
266 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
267 +
268 +**HMI Settings**
269 +
270 +(% class="table-bordered" %)
271 +|**Item**|**Settings**|**Note**
272 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
273 +|Connection|RS422/RS485|
274 +|Baud rate|9600|
275 +|Data bit|7|
276 +|Parity|EVEN|
277 +|Stop bit|1|
278 +|PLC station No.|1|
279 +
280 +**Address List**
281 +
282 +(% class="table-bordered" %)
283 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
284 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
285 +|Y|Y|Y o|0~~303237|
286 +|M|M|M d|0~~99999|
287 +|T|T|T d|0~~99999|
288 +|C|C|C d|0~~99999|
289 +|S|S|S d|0~~99999|
290 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
291 +|Y|Y|Y o|0~~303237|
292 +|M|M|M d|0~~99999|
293 +|T|T|T d|0~~99999|
294 +|C|C|C d|0~~199|
295 +|D|D|D d|0~~7999|
296 +|S|S|S d|0~~99999|
297 +|SD|SD|SD d|8000~~9999|
298 +
299 +**Cable Wiring**
300 +
301 +* **RS485**
302 +
303 +(% style="text-align:center" %)
304 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
305 +
306 +* **RS422**
307 +
308 +(% style="text-align:center" %)
309 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
310 +
311 +**✎Note:**
312 +
313 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
314 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
315 +
316 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
317 +
318 +
319 +== **HMI and Wecon LX5V serial communication** ==
320 +
319 319  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
320 320  
321 321  **Software configuration of PLC**
... ... @@ -466,7 +466,8 @@
466 466  
467 467  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
468 468  
469 -= =
471 +(% class="wikigeneratedid" %)
472 += =
470 470  
471 471  = **Allen-Bradley** =
472 472  
... ... @@ -2646,7 +2646,7 @@
2646 2646  
2647 2647  **✎Note:** COM3 only available in PI8000/PI9000 series.
2648 2648  
2649 -= =
2652 += =
2650 2650  
2651 2651  = **Printer** =
2652 2652