Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,6 +87,7 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 +== **LX3V Serial Protocol** == 90 90 91 91 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 92 92 ... ... @@ -140,7 +140,8 @@ 140 140 141 141 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 142 142 143 -== HMI settings == 144 +(% class="wikigeneratedid" id="HHMIsettings" %) 145 +**HMI settings** 144 144 145 145 **Download PIStudio Software** 146 146 ... ... @@ -229,7 +229,8 @@ 229 229 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 230 230 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 231 231 232 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 233 233 234 234 **Download PLC Software** 235 235 ... ... @@ -314,7 +314,7 @@ 314 314 (% style="text-align:center" %) 315 315 [[image:image-20220819105928-9.png||height="229" width="669"]] 316 316 317 -= ** HMI and WeconLX5Vserialcommunication** =320 +== **LX5V Serial Protocol** == 318 318 319 319 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 320 320 ... ... @@ -392,7 +392,7 @@ 392 392 393 393 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 394 394 395 -== ** HMI and WeconLX5V-N Ethernetcommunication** ==398 +== **LX5V-N Ethernet protocol** == 396 396 397 397 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 398 398 ... ... @@ -466,10 +466,46 @@ 466 466 467 467 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 468 468 469 -= = 472 += Create communication with **Rockwell PLC** = 470 470 471 -= **Allen-Bradley** = 472 472 475 +== **MicroLogix** == 476 + 477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 + 479 +**HMI Settings** 480 + 481 +(% class="table-bordered" %) 482 +|**Item**|**Settings**|**Note** 483 +|Protocol|Allen-Bradlley MicroLogix| 484 +|Connection|RS232| 485 +|Baud rate|19200| 486 +|Data bit|8| 487 +|Parity|None| 488 +|Stop bit|1| 489 +|PLC station No.|1| 490 + 491 +**Address List** 492 + 493 +(% class="table-bordered" %) 494 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 +|O|O d.d|0.0~~255.15| 497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|S|S d.d|0.0~~255.15| 499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 +|(% rowspan="9" %)Word|S|S d|0~~255| 501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 +|TP|TP nnhh|0~~ffff 503 +|CS|CS nnhh|0~~ffff 504 +|CP|CP nnhh|0~~ffff 505 +|N|N nnhh|0~~ffff 506 +|C|C nnhh|0~~ffff 507 +|T|T nnhh|0~~ffff 508 +|R|R nnhh|0~~ffff 509 + 510 +**Cable Wiring** 511 + 473 473 == **FreeTag Ethernet/IP (CompactLogix)** == 474 474 475 475 Allen-Brandly CompactLogix ... ... @@ -527,43 +527,8 @@ 527 527 (% style="text-align:center" %) 528 528 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 529 529 530 -== **MicroLogix**==569 +== == 531 531 532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 533 - 534 -**HMI Settings** 535 - 536 -(% class="table-bordered" %) 537 -|**Item**|**Settings**|**Note** 538 -|Protocol|Allen-Bradlley MicroLogix| 539 -|Connection|RS232| 540 -|Baud rate|19200| 541 -|Data bit|8| 542 -|Parity|None| 543 -|Stop bit|1| 544 -|PLC station No.|1| 545 - 546 -**Address List** 547 - 548 -(% class="table-bordered" %) 549 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 551 -|O|O d.d|0.0~~255.15| 552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 553 -|S|S d.d|0.0~~255.15| 554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 555 -|(% rowspan="9" %)Word|S|S d|0~~255| 556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 557 -|TP|TP nnhh|0~~ffff 558 -|CS|CS nnhh|0~~ffff 559 -|CP|CP nnhh|0~~ffff 560 -|N|N nnhh|0~~ffff 561 -|C|C nnhh|0~~ffff 562 -|T|T nnhh|0~~ffff 563 -|R|R nnhh|0~~ffff 564 - 565 -**Cable Wiring** 566 - 567 567 (% style="text-align:center" %) 568 568 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 569 569 ... ... @@ -2646,7 +2646,7 @@ 2646 2646 2647 2647 **✎Note:** COM3 only available in PI8000/PI9000 series. 2648 2648 2649 -= = 2653 += = 2650 2650 2651 2651 = **Printer** = 2652 2652