Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 66.1
edited by Ben
on 2022/08/29 14:06
Change comment: There is no comment for this version
To version 73.1
edited by Ben
on 2022/08/29 14:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,7 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 +== **LX3V Serial Protocol** ==
90 90  
91 91  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 92  
... ... @@ -140,7 +140,8 @@
140 140  
141 141  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 142  
143 -== HMI settings ==
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
144 144  
145 145  **Download PIStudio Software**
146 146  
... ... @@ -229,7 +229,8 @@
229 229  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 230  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 231  
232 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
233 233  
234 234  **Download PLC Software**
235 235  
... ... @@ -314,7 +314,7 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **HMI and Wecon LX5V serial communication** =
320 +== **LX5V Serial Protocol** ==
318 318  
319 319  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
320 320  
... ... @@ -392,7 +392,7 @@
392 392  
393 393  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
394 394  
395 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
396 396  
397 397  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
398 398  
... ... @@ -466,10 +466,50 @@
466 466  
467 467  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
468 468  
469 -= =
472 += Create communication with **Rockwell PLC** =
470 470  
471 -= **Allen-Bradley** =
472 472  
475 +== **MicroLogix Protocol** ==
476 +
477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
478 +
479 +**HMI Settings**
480 +
481 +(% class="table-bordered" %)
482 +|**Item**|**Settings**|**Note**
483 +|Protocol|Allen-Bradlley MicroLogix|
484 +|Connection|RS232|
485 +|Baud rate|19200|
486 +|Data bit|8|
487 +|Parity|None|
488 +|Stop bit|1|
489 +|PLC station No.|1|
490 +
491 +**Address List**
492 +
493 +(% class="table-bordered" %)
494 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
496 +|O|O d.d|0.0~~255.15|
497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|S|S d.d|0.0~~255.15|
499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
500 +|(% rowspan="9" %)Word|S|S d|0~~255|
501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
502 +|TP|TP nnhh|0~~ffff
503 +|CS|CS nnhh|0~~ffff
504 +|CP|CP nnhh|0~~ffff
505 +|N|N nnhh|0~~ffff
506 +|C|C nnhh|0~~ffff
507 +|T|T nnhh|0~~ffff
508 +|R|R nnhh|0~~ffff
509 +
510 +**Cable Wiring**
511 +
512 +
513 +(% style="text-align:center" %)
514 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
515 +
473 473  == **FreeTag Ethernet/IP (CompactLogix)** ==
474 474  
475 475  Allen-Brandly CompactLogix
... ... @@ -527,46 +527,6 @@
527 527  (% style="text-align:center" %)
528 528  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
529 529  
530 -== **MicroLogix** ==
531 -
532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
533 -
534 -**HMI Settings**
535 -
536 -(% class="table-bordered" %)
537 -|**Item**|**Settings**|**Note**
538 -|Protocol|Allen-Bradlley MicroLogix|
539 -|Connection|RS232|
540 -|Baud rate|19200|
541 -|Data bit|8|
542 -|Parity|None|
543 -|Stop bit|1|
544 -|PLC station No.|1|
545 -
546 -**Address List**
547 -
548 -(% class="table-bordered" %)
549 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
551 -|O|O d.d|0.0~~255.15|
552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
553 -|S|S d.d|0.0~~255.15|
554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
555 -|(% rowspan="9" %)Word|S|S d|0~~255|
556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
557 -|TP|TP nnhh|0~~ffff
558 -|CS|CS nnhh|0~~ffff
559 -|CP|CP nnhh|0~~ffff
560 -|N|N nnhh|0~~ffff
561 -|C|C nnhh|0~~ffff
562 -|T|T nnhh|0~~ffff
563 -|R|R nnhh|0~~ffff
564 -
565 -**Cable Wiring**
566 -
567 -(% style="text-align:center" %)
568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
569 -
570 570  == **AB PLC address edit** ==
571 571  
572 572  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -2646,7 +2646,7 @@
2646 2646  
2647 2647  **✎Note:** COM3 only available in PI8000/PI9000 series.
2648 2648  
2649 -= =
2652 += =
2650 2650  
2651 2651  = **Printer** =
2652 2652