Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,6 +87,7 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 +== **LX3V Serial Protocol** == 90 90 91 91 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 92 92 ... ... @@ -140,7 +140,8 @@ 140 140 141 141 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 142 142 143 -== HMI settings == 144 +(% class="wikigeneratedid" id="HHMIsettings" %) 145 +**HMI settings** 144 144 145 145 **Download PIStudio Software** 146 146 ... ... @@ -229,7 +229,8 @@ 229 229 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 230 230 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 231 231 232 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 233 233 234 234 **Download PLC Software** 235 235 ... ... @@ -314,7 +314,7 @@ 314 314 (% style="text-align:center" %) 315 315 [[image:image-20220819105928-9.png||height="229" width="669"]] 316 316 317 -= ** HMI and WeconLX5Vserialcommunication** =320 +== **LX5V Serial Protocol** == 318 318 319 319 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 320 320 ... ... @@ -392,11 +392,10 @@ 392 392 393 393 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 394 394 395 -== ** HMI and WeconLX5V-N Ethernetcommunication** ==398 +== **LX5V-N Ethernet protocol** == 396 396 397 397 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 398 398 399 - 400 400 **Software configuration of PLC** 401 401 402 402 **1)PLC programming software** ... ... @@ -466,10 +466,49 @@ 466 466 467 467 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 468 468 469 -= = 471 += Create communication with **Rockwell PLC** = 470 470 471 -= ** Allen-Bradley** =473 +== **MicroLogix Protocol** == 472 472 475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 476 + 477 +**HMI Settings** 478 + 479 +(% class="table-bordered" %) 480 +|**Item**|**Settings**|**Note** 481 +|Protocol|Allen-Bradlley MicroLogix| 482 +|Connection|RS232| 483 +|Baud rate|19200| 484 +|Data bit|8| 485 +|Parity|None| 486 +|Stop bit|1| 487 +|PLC station No.|1| 488 + 489 +**Address List** 490 + 491 +(% class="table-bordered" %) 492 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 494 +|O|O d.d|0.0~~255.15| 495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 496 +|S|S d.d|0.0~~255.15| 497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|(% rowspan="9" %)Word|S|S d|0~~255| 499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 500 +|TP|TP nnhh|0~~ffff 501 +|CS|CS nnhh|0~~ffff 502 +|CP|CP nnhh|0~~ffff 503 +|N|N nnhh|0~~ffff 504 +|C|C nnhh|0~~ffff 505 +|T|T nnhh|0~~ffff 506 +|R|R nnhh|0~~ffff 507 + 508 +**Cable Wiring** 509 + 510 + 511 +(% style="text-align:center" %) 512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 + 473 473 == **FreeTag Ethernet/IP (CompactLogix)** == 474 474 475 475 Allen-Brandly CompactLogix ... ... @@ -527,46 +527,6 @@ 527 527 (% style="text-align:center" %) 528 528 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 529 529 530 -== **MicroLogix** == 531 - 532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 533 - 534 -**HMI Settings** 535 - 536 -(% class="table-bordered" %) 537 -|**Item**|**Settings**|**Note** 538 -|Protocol|Allen-Bradlley MicroLogix| 539 -|Connection|RS232| 540 -|Baud rate|19200| 541 -|Data bit|8| 542 -|Parity|None| 543 -|Stop bit|1| 544 -|PLC station No.|1| 545 - 546 -**Address List** 547 - 548 -(% class="table-bordered" %) 549 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 551 -|O|O d.d|0.0~~255.15| 552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 553 -|S|S d.d|0.0~~255.15| 554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 555 -|(% rowspan="9" %)Word|S|S d|0~~255| 556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 557 -|TP|TP nnhh|0~~ffff 558 -|CS|CS nnhh|0~~ffff 559 -|CP|CP nnhh|0~~ffff 560 -|N|N nnhh|0~~ffff 561 -|C|C nnhh|0~~ffff 562 -|T|T nnhh|0~~ffff 563 -|R|R nnhh|0~~ffff 564 - 565 -**Cable Wiring** 566 - 567 -(% style="text-align:center" %) 568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 569 - 570 570 == **AB PLC address edit** == 571 571 572 572 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. ... ... @@ -584,117 +584,280 @@ 584 584 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 585 585 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 586 586 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 587 -| (% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**588 -| (% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255589 -| (% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF590 -| (% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF591 -| (% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF592 -| (% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF593 -| (% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF594 -| (% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF588 +|**PLC word address type**|**Address format**|**Address range** 589 +|S|ddd|S0 ~~ 255 590 +|TS|ffff|TS0 ~~ FFFF 591 +|TP|ffff|TP0 ~~ FFFF 592 +|CS|ffff|CS0 ~~ FFFF 593 +|CP|ffff|CP0 ~~ FFFF 594 +|N|ffff|N0 ~~ FFFF 595 +|F|ffff|F0 ~~ FFFF 595 595 596 -= **Barcodecanner** =597 += (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** = 597 597 598 - Supported:DELI 14880barcodescanner599 +== **S7-200 Smart Ethernet** == 599 599 601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module. 602 + 603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]] 604 + 600 600 **HMI Setting** 601 601 602 602 (% class="table-bordered" %) 603 603 |**Items**|**Settings**|**Note** 604 -|Protocol|Barcode Scanner| 605 -|Connection|USB| 609 +|Protocol|Simens S7-200 Smart Ethernet| 610 +|Connection|Ethernet| 611 +|Port No.|102| 612 +|PLC station No.|2| 606 606 607 -** Operating Procedures**614 +**Address List** 608 608 609 -Select [Barcode Scanner]; 616 +(% class="table-bordered" %) 617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 619 +|Q|Q|Q ddddd.o|0.0~~99999.7| 620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 621 +|V|V|V ddddd.o|0.0~~99999.7| 622 +|M|M|M ddddd.o|0.0~~99999.7| 623 +|SM|SM|ddddd.o|0.0~~99999.7| 624 +|S|S|ddddd.o|0.0~~99999.7|Read only 625 +|T|T|ddddd|0~~99999|Timer state, read only 626 +|C|C|ddddd|0~~99999|Counter state, read only 627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 628 +|Q|QW|QW ddddd|0~~99999| 629 +|AI|AIW|AIW ddddd|0~~99999| 630 +|AQ|VB|VB ddddd|0~~99999| 631 +|V|VW|VW ddddd|0~~99998|((( 632 +VW0=VB (0~~1) 610 610 634 +VW2=VB (2~~3) 635 + 636 +Address value is a multiple of 2 637 +))) 638 +|V|VD|VD ddddd|0~~99998|((( 639 +VD0=VB (0~~3) 640 + 641 +VD2=VB (4~~7) 642 + 643 +Address value is a multiple of 4 644 +))) 645 +|M|MB|MB ddddd|0~~99999| 646 +|M|MW|MW ddddd|0~~99999|((( 647 +MW0=MB(0~~1) 648 + 649 +MW2=MB(2~~3) 650 + 651 +Address value is a multiple of 2 652 +))) 653 +|M|MD|MD ddddd|0~~99999|((( 654 +MD0=MB(0~~3) 655 + 656 +MD4=MB(4~~7) 657 + 658 +Address value is a multiple of 4 659 +))) 660 +|T|TW|TW ddddd|0~~99999|Value of timer 661 +|C|CW|CW ddddd|0~~99999|Value of counter 662 +|W|SW|SW ddddd|0~~99999| 663 + 664 +**Communication Settings** 665 + 666 +Enable HMI Ethernet in [Project Settings]; 667 + 611 611 (% style="text-align:center" %) 612 -[[image:12.PLC Protocol_html_ 55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 613 613 614 -Set addressforreceiving;671 +Set PLC IP in [Device IP] settings; 615 615 616 -Set correct length; 673 +(% style="text-align:center" %) 674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 617 617 676 +* PLC IP Address: PLC IP 677 +* PLC pot No.: 102(fixed) 678 +* Network:TCP_Client_2N(fixed) 679 + 618 618 (% style="text-align:center" %) 619 -[[image:12.PLC Protocol_html_ 30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 620 620 621 -* *✎Note:**683 +* Wait timeout: depend on actual network situation (more than 1500 ms) 622 622 623 -* The protocol uploads the information acquired by the USB scanner to the HMI; 624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 625 -* Recommended model: DELI 14880 barcode scanner; 685 +**Cable Wiring** 626 626 627 -= **Hitachi EHV Series (Ethernet)** = 687 +(% style="text-align:center" %) 688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 628 628 629 -S upportedseries: Hitachi EHV series690 +== **S7-300 Ethernet** == 630 630 631 - **HMISettings**692 +Supported Series: Siemens S7-300 series PLC 632 632 694 +**HMI Setting** 695 + 633 633 (% class="table-bordered" %) 634 634 |**Items**|**Settings**|**Note** 635 -|Protocol| HitachiEHVseries|698 +|Protocol|Simens S7-300 Ethernet| 636 636 |Connection|Ethernet| 637 -|Port No.|3004~~3007| 700 +|Port No.|102| 701 +|PLC station No.|2|Need to be same as the PLC setting 638 638 639 639 **Address List** 640 640 641 641 (% class="table-bordered" %) 642 -|**Type**|**Register**|**Range**|**Format**|**Note** 643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 644 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 646 -H1H2H3H4 Module main number 706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 708 +|Q|Q|Q ddddd.o|0.0~~99999.7| 709 +|M|M|M ddddd.o|0.0~~99999.7| 710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|((( 711 +nn: block number; 647 647 648 -H1: Remote number 713 +dddd: address; 714 +))) 715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999| 716 +|Q|QW|QW ddddd|0~~99999| 717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999| 718 +|MW|MW ddddd|0~~99999|((( 719 +MW0=MB(0~~1) 649 649 650 - H2: Unit number721 +MW2=MB(2~~3) 651 651 652 -H3: Slot number 723 +Address value is a multiple of 2 724 +))) 725 +|MD|MD ddddd|0~~99999|((( 726 +MD0=MB(0~~3) 653 653 654 - H4: Word number ofModule728 +MD4=MB(4~~7) 655 655 656 -H Sub number of Module 730 +Address value is a multiple of 4 731 +))) 732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 733 +nn: block number; 657 657 658 -For example:X21.3 735 +dddd: address 736 +))) 737 +|DBxDBW|DBxDBW nndddd|0~~99999999 738 +|DBxDBD|DBxDBD nndddd|0~~99999999 659 659 660 - Slotumber2740 +**Communication Settings** 661 661 662 - Wordnumberofmodule is1742 +Enable HMI Ethernet in [Project Settings]; 663 663 664 -Bit number of module is 3 744 +(% style="text-align:center" %) 745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 665 665 666 -Remote number and unit number are 0 747 +Set PLC IP in [Device IP] settings; 748 + 749 +(% style="text-align:center" %) 750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]] 751 + 752 +* PLC IP Address: PLC IP 753 +* PLC pot No.: 102(fixed) 754 +* Network:TCP_Client_2N(fixed) 755 + 756 +(% style="text-align:center" %) 757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]] 758 + 759 +* Wait timeout: depend on actual network situation (more than 1500 ms) 760 + 761 +**Cable Wiring** 762 + 763 +(% style="text-align:center" %) 764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 765 + 766 +== **S7-1200 Ethernet** == 767 + 768 +Supported Series: Siemens S7-1200 769 + 770 +**HMI Setting** 771 + 772 +(% class="table-bordered" %) 773 +|**Items**|**Settings**|**Note** 774 +|Protocol|Siemens S7-1200| 775 +|Connection|Ethernet| 776 +|Port No.|102| 777 +|PLC station No.|2| 778 + 779 +**Address List** 780 + 781 +(% class="table-bordered" %) 782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 783 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 784 +d:0~-~-9999 785 + 786 +o:0-7 787 +)))| 788 +|Q|Q|Q d.o|((( 789 +d:0~-~-9999 790 + 791 +o:0-7 792 +)))| 793 +|M|M|M d.o|((( 794 +d:0~-~-9999 795 + 796 +o:0-7 797 +)))| 798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 799 +nn:0-9999, 800 + 801 +dddd:0-9999, 802 + 803 +o:0-7 804 +)))|((( 805 +nn:DB No. 806 + 807 +dddd:address value 808 + 809 +o: digit address 667 667 ))) 668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 669 -|R|0 – FF.f (Hex)|R HH.h| 670 -|L|0 - 73FF.f (Hex)|L HHHH.h| 671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 673 -H1H2H3H4 Module main number 811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 812 +|M|MW|MW d|d:0-99999|((( 813 +MW0=MB(0~~1) 674 674 675 - H1: Remote number815 +MW2=MB(2~~3) 676 676 677 -H2: Unit number 817 +Address value is a multiple of 2 818 +))) 819 +|M|MD|MD d|d:0-99999|((( 820 +MD0=MB(0~~3) 678 678 679 - H3: Slot number822 +MD4=MB(4~~7) 680 680 681 -H4: Word number of module 824 +Address value is a multiple of 4 825 +))) 826 +|I|IW|IW d|d:0-99999| 827 +|Q|QW|QW d|d:0-99999| 828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 829 +nn:0-9999 682 682 683 -For example:WX21 831 +dddd:0-9999 832 +)))|((( 833 +nn:DB No. 684 684 685 -Word number of module is 1 835 +dddd:address value 836 +))) 837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 838 +nn:0-9999 686 686 687 -Slot number is 2 840 +dddd:0-9999 841 +)))|((( 842 +nn:DB No. 688 688 689 -Remote number and unit number are 0 844 +dddd:address value 845 + 846 +Address value is a multiple of 2 690 690 ))) 691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 692 -|WR|0 – FFFF (Hex)|WR HHHH| 693 -|WL|0 - 73FF (Hex)|WL HHHH| 694 -|TC|0 - 2559|TC DDDD| 848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 849 +nn:0-9999 695 695 696 -**Communication settings in HMI** 851 +dddd:0-9999 852 +)))|((( 853 +nn:DB No. 697 697 855 +dddd:address value 856 + 857 +Address value is a multiple of 4 858 +))) 859 + 860 +**Communication Settings** 861 + 698 698 Enable HMI Ethernet in [Project Settings]; 699 699 700 700 (% style="text-align:center" %) ... ... @@ -703,178 +703,285 @@ 703 703 Set PLC IP in [Device IP] settings; 704 704 705 705 (% style="text-align:center" %) 706 -[[image:12.PLC Protocol_html_ d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 707 707 708 -** PLC Configuration**872 +**✎Note:** 709 709 710 -Connect with PLC, select[Online mode]; 874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 711 711 712 -(% style="text-align:center" %) 713 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 877 +**PLC Settings** 714 714 715 - Set IP address,it is the same LAN parameters with HMI;879 +Add BD 716 716 881 +* Please uncheck [Symbolic access only] option; 882 + 717 717 (% style="text-align:center" %) 718 -[[image:12.PLC Protocol_html_ 1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]] 719 719 720 - 3)SavePLC communicationparameter,andrestart PLC886 +Address settings, using BD2 as example. 721 721 722 -**PLC Monitor Mode** 888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 889 +* 2 represent DB block number 890 +* xxxx represent address 723 723 724 - Connect withPLCand choose to “online” mode892 +**Such as:** 725 725 894 +* DBxDBB20000 = DB2.DBB0 895 +* DBxDBW20004 = DB2.DBW4 896 + 726 726 (% style="text-align:center" %) 727 -[[image:12.PLC Protocol_html_c dac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]] 728 728 729 - OpenI/Omonitorsheet1900 +**How to connect with S7-1200 Firmware V4.0** 730 730 731 -(% style="text-align:center" %) 732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 902 +PLC configuration 733 733 734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 904 +* Double click [device configuration] in Siemens via software 905 +* Double click [protection] to enter protection configuration screen 735 735 736 736 (% style="text-align:center" %) 737 -[[image:12.PLC Protocol_html_774 652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]] 738 738 739 - Entertheregisteraddress,click OKtoviewthevalueof the register.910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 740 740 741 741 (% style="text-align:center" %) 742 -[[image:12.PLC Protocol_html_ bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]] 743 743 744 -(% style="text-align:center" %) 745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 915 +DB settings 746 746 747 -**✎Note:** 917 +* Right click [DB], select [properties] 918 +* Uncheck [optimized block access] 748 748 749 -* Both word registers and bit registers support even continuous read/write functions; 750 -* The range of registers is based on the specific PLC type; 751 - 752 752 **Cable Wiring** 753 753 754 754 (% style="text-align:center" %) 755 755 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 756 756 757 -= ** IEC60870-5104 Client** =925 +== **LOGO Ethernet** == 758 758 759 - **HMISetting**927 +Supported Series: Siemens Logo 0BA0 series 760 760 929 +**HMI Settings** 930 + 761 761 (% class="table-bordered" %) 762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 932 +|**Items**|**Settings**|**Note** 933 +|Protocol|Siemens LOGO| 934 +|Connection|Ethernet| 935 +|Port No.|102| 936 +|PLC station No.|2| 766 766 767 767 **Address List** 768 768 769 769 (% class="table-bordered" %) 770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 772 -|(% style="width:461px" %)SCNA|0~~16777215.7 773 -|(% style="width:461px" %)DPTB|0~~16777215.7 774 -|(% style="width:461px" %)DCNA|0~~16777215.7 775 -|(% style="width:461px" %)METF|0~~16777215.7 776 -|(% style="width:461px" %)SENC|0~~16777215.7 777 -|(% style="width:461px" %)SENA|0~~16777215.7 778 -|(% style="width:461px" %)MENA|0~~16777215.7 779 -|(% style="width:461px" %)METD|0~~16777215.7 780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 781 -|(% style="width:461px" %)SCNA|0~~16777215 782 -|(% style="width:461px" %)DPTB|0~~16777215 783 -|(% style="width:461px" %)DCNA|0~~16777215 784 -|(% style="width:461px" %)SENA|0~~16777215 785 -|(% style="width:461px" %)MENA|0~~16777215 786 -|(% style="width:461px" %)METD|0~~16777215 787 -|(% style="width:461px" %)INRO|0~~16777215 788 -|(% style="width:461px" %)TIMESYN|0~~16777215 789 -|(% style="width:461px" %)TIMEZ|0~~16777215 790 -|(% style="width:461px" %)NTP|0~~16777215 791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 792 -|(% style="width:461px" %)SENC|0~~16777215 941 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 942 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 943 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 944 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 945 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 946 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 947 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 948 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 949 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 950 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 951 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 952 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 953 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 954 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 955 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 956 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 793 793 794 -** AddressConfiguration**958 +**PLC Settings in LOGO Software:** 795 795 796 - The address registers of the IEC60870-5-104 protocolare SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocolneedso be added withanxtensiontag "ASDU", which could only be added inthe[Address IdentificationLibrary],other placesare noteditable, that is,the read address in the object or script is not editable.960 +Click [Tools]~-~-[Ethernet Connections],shown as below. 797 797 798 798 (% style="text-align:center" %) 799 -[[image:12.PLC Protocol_html_ ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]963 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]] 800 800 965 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 966 + 801 801 (% style="text-align:center" %) 802 -[[image:12.PLC Protocol_html_ 23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]968 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]] 803 803 804 - Extendedtagname970 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 805 805 806 -Address range for the extended tag. 972 +(% style="text-align:center" %) 973 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]] 807 807 808 -** CommunicationSettings**975 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 809 809 810 -Enable HMI Ethernet in [Project Settings]; 977 +(% style="text-align:center" %) 978 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]] 811 811 980 + 812 812 (% style="text-align:center" %) 813 -[[image:12.PLC Protocol_html_ 43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]982 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]] 814 814 984 + 985 +**HMI Communication Settings** 986 + 815 815 Set PLC IP in [Device IP] settings; 816 816 817 817 (% style="text-align:center" %) 818 -[[image: 12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]990 +[[image:SiemensLOGODeviceIP.png]] 819 819 992 +Enable HMI Ethernet in [Project Settings]; 993 + 994 +(% style="text-align:center" %) 995 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]] 996 + 997 +TSAP setting 998 + 999 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register. 1000 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC. 1001 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC. 1002 + 1003 +**✎Note:** 1004 + 1005 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192. 1006 + 1007 +(% style="text-align:center" %) 1008 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]] 1009 + 1010 + 1011 +* AI word address and Ibit address are read-only and cannot be written on HMI. 1012 +* VW address should be even number.such as VW0, VW2, VW4... 1013 +* VD address it takes two VW addresses.such as VD0,VD4,VD8... 1014 +* Written value of RTC cannot exceed 255. 1015 + 820 820 **Cable Wiring** 821 821 822 822 (% style="text-align:center" %) 823 823 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 824 824 825 -= ** LGXGKFEnetEthernet** =1021 +== **S7-XXX Ethernet** == 826 826 827 -Supported Series: LSXGT seriesXGKCPU with XGL-EFMTEthernet module1023 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 828 828 829 -**HMI Setting s**1025 +**HMI Setting** 830 830 831 -(% class="table-bordered" %) 832 -|**Items**|**Settings**|**Note** 833 -|Protocol|LG XGK FEnet(Ethernet)| 834 -|Connection|Ethernet| 835 -|Port No.|2004| 1027 +(% class="table-bordered" style="width:823px" %) 1028 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note** 1029 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %) 1030 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %) 1031 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %) 1032 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %) 1033 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %) 836 836 1035 +Slot from TIA Portal is equal to Device No. of PIStudio 1036 + 1037 +Rack from TIA Portal is equal to HMI No. of PIStudio 1038 + 1039 +(% style="text-align:center" %) 1040 +[[image:S7-XXXCommunication Settings.png]] 1041 + 1042 +(% style="text-align:center" %) 1043 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]] 1044 + 837 837 **Address List** 838 838 839 839 (% class="table-bordered" %) 840 -|**Type**|**Register**|**Range**|**Format**|**Note** 841 -|(% rowspan="14" %)Word|P|0~~2047|P d| 842 -|M|0~~2047|M d| 843 -|K|0~~2047|K d| 844 -|F|0~~2047|F d| 845 -|T|0~~2047|T d| 846 -|C|0~~2047|C d| 847 -|Z|0~~127|Z d| 848 -|S|0~~127|S d| 849 -|L|0~~11263|L d| 850 -|N|0~~21503|N d| 851 -|D|0~~32767|D d| 852 -|R|0~~32767|R d| 853 -|ZR|0~~65535|ZR d| 854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1048 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 1049 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 1050 +d:0~-~-9999 855 855 856 -**✎Note:** 1052 +o:0-7 1053 +)))| 1054 +|Q|Q|Q d.o|((( 1055 +d:0~-~-9999 857 857 858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 860 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 1057 +o:0-7 1058 +)))| 1059 +|M|M|M d.o|((( 1060 +d:0~-~-9999 861 861 862 -**Communication settings in HMI** 1062 +o:0-7 1063 +)))| 1064 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 1065 +nn:0-9999, 863 863 1067 +dddd:0-9999, 1068 + 1069 +o:0-7 1070 +)))|((( 1071 +nn:DB No. 1072 + 1073 +dddd:address value 1074 + 1075 +o: digit address 1076 +))) 1077 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 1078 +|M|MW|MW d|d:0-99999|((( 1079 +MW0=MB(0~~1) 1080 + 1081 +MW2=MB(2~~3) 1082 + 1083 +Address value is a multiple of 2 1084 +))) 1085 +|M|MD|MD d|d:0-99999|((( 1086 +MD0=MB(0~~3) 1087 + 1088 +MD4=MB(4~~7) 1089 + 1090 +Address value is a multiple of 4 1091 +))) 1092 +|I|IW|IW d|d:0-99999| 1093 +|Q|QW|QW d|d:0-99999| 1094 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 1095 +nn:0-9999 1096 + 1097 +dddd:0-9999 1098 +)))|((( 1099 +nn:DB No. 1100 + 1101 +dddd:address value 1102 +))) 1103 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 1104 +nn:0-9999 1105 + 1106 +dddd:0-9999 1107 +)))|((( 1108 +nn:DB No. 1109 + 1110 +dddd:address value 1111 + 1112 +Address value is a multiple of 2 1113 +))) 1114 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 1115 +nn:0-9999 1116 + 1117 +dddd:0-9999 1118 +)))|((( 1119 +nn:DB No. 1120 + 1121 +dddd:address value 1122 + 1123 +Address value is a multiple of 4 1124 +))) 1125 + 1126 +**Communication Settings** 1127 + 864 864 Enable HMI Ethernet in [Project Settings]; 865 865 866 866 (% style="text-align:center" %) 867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 1131 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]] 868 868 869 869 Set PLC IP in [Device IP] settings; 870 870 871 871 (% style="text-align:center" %) 872 -[[image:12.PLC Protocol_html_ a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]1136 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 873 873 1138 +**✎Note:** 1139 + 1140 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens. 1141 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 1142 + 874 874 **Cable Wiring** 875 875 876 - = **Mitsubishi**=1145 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 877 877 1147 += Create communication with **Mitsubishi** = 1148 + 878 878 == **FX1S, 1N, 2N Series** == 879 879 880 880 Supported Series: Mitsubishi FX1S, FX1N, FX2N series ... ... @@ -2646,8 +2646,6 @@ 2646 2646 2647 2647 **✎Note:** COM3 only available in PI8000/PI9000 series. 2648 2648 2649 -= = 2650 - 2651 2651 = **Printer** = 2652 2652 2653 2653 == **TSPL label printer** == ... ... @@ -2848,3 +2848,284 @@ 2848 2848 2849 2849 (% style="text-align:center" %) 2850 2850 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 3120 + 3121 += **Barcode Scanner** = 3122 + 3123 +Supported: DELI 14880 barcode scanner 3124 + 3125 +**HMI Setting** 3126 + 3127 +|**Items**|**Settings**|**Note** 3128 +|Protocol|Barcode Scanner| 3129 +|Connection|USB| 3130 + 3131 +**Operating Procedures** 3132 + 3133 +Select [Barcode Scanner]; 3134 + 3135 +(% style="text-align:center" %) 3136 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 3137 + 3138 +Set address for receiving; 3139 + 3140 +Set correct length; 3141 + 3142 +(% style="text-align:center" %) 3143 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 3144 + 3145 +**✎Note:** 3146 + 3147 +* The protocol uploads the information acquired by the USB scanner to the HMI; 3148 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 3149 +* Recommended model: DELI 14880 barcode scanner; 3150 + 3151 += **Hitachi EHV Series (Ethernet)** = 3152 + 3153 +Supported series: Hitachi EHV series 3154 + 3155 +**HMI Settings** 3156 + 3157 +(% class="table-bordered" %) 3158 +|**Items**|**Settings**|**Note** 3159 +|Protocol|Hitachi EHV series| 3160 +|Connection|Ethernet| 3161 +|Port No.|3004~~3007| 3162 + 3163 +**Address List** 3164 + 3165 +(% class="table-bordered" %) 3166 +|**Type**|**Register**|**Range**|**Format**|**Note** 3167 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 3168 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 3169 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 3170 +H1H2H3H4 Module main number 3171 + 3172 +H1: Remote number 3173 + 3174 +H2: Unit number 3175 + 3176 +H3: Slot number 3177 + 3178 +H4: Word number of Module 3179 + 3180 +H Sub number of Module 3181 + 3182 +For example:X21.3 3183 + 3184 +Slot number 2 3185 + 3186 +Word number of module is 1 3187 + 3188 +Bit number of module is 3 3189 + 3190 +Remote number and unit number are 0 3191 +))) 3192 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 3193 +|R|0 – FF.f (Hex)|R HH.h| 3194 +|L|0 - 73FF.f (Hex)|L HHHH.h| 3195 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 3196 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 3197 +H1H2H3H4 Module main number 3198 + 3199 +H1: Remote number 3200 + 3201 +H2: Unit number 3202 + 3203 +H3: Slot number 3204 + 3205 +H4: Word number of module 3206 + 3207 +For example:WX21 3208 + 3209 +Word number of module is 1 3210 + 3211 +Slot number is 2 3212 + 3213 +Remote number and unit number are 0 3214 +))) 3215 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 3216 +|WR|0 – FFFF (Hex)|WR HHHH| 3217 +|WL|0 - 73FF (Hex)|WL HHHH| 3218 +|TC|0 - 2559|TC DDDD| 3219 + 3220 +**Communication settings in HMI** 3221 + 3222 +Enable HMI Ethernet in [Project Settings]; 3223 + 3224 +(% style="text-align:center" %) 3225 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3226 + 3227 +Set PLC IP in [Device IP] settings; 3228 + 3229 +(% style="text-align:center" %) 3230 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 3231 + 3232 +**PLC Configuration** 3233 + 3234 +Connect with PLC, select[Online mode]; 3235 + 3236 +(% style="text-align:center" %) 3237 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 3238 + 3239 +Set IP address, it is the same LAN parameters with HMI; 3240 + 3241 +(% style="text-align:center" %) 3242 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 3243 + 3244 +3) Save PLC communication parameter, and restart PLC 3245 + 3246 +**PLC Monitor Mode** 3247 + 3248 +Connect with PLC and choose to “online” mode 3249 + 3250 +(% style="text-align:center" %) 3251 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 3252 + 3253 +Open I/O monitor sheet1 3254 + 3255 +(% style="text-align:center" %) 3256 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 3257 + 3258 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 3259 + 3260 +(% style="text-align:center" %) 3261 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 3262 + 3263 +Enter the register address, click OK to view the value of the register. 3264 + 3265 +(% style="text-align:center" %) 3266 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 3267 + 3268 +(% style="text-align:center" %) 3269 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 3270 + 3271 +**✎Note:** 3272 + 3273 +* Both word registers and bit registers support even continuous read/write functions; 3274 +* The range of registers is based on the specific PLC type; 3275 + 3276 +**Cable Wiring** 3277 + 3278 +(% style="text-align:center" %) 3279 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 3280 + 3281 += **IEC60870-5 104 Client** = 3282 + 3283 +**HMI Setting** 3284 + 3285 +(% class="table-bordered" %) 3286 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 3287 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 3288 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 3289 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 3290 + 3291 +**Address List** 3292 + 3293 +(% class="table-bordered" %) 3294 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 3295 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 3296 +|(% style="width:461px" %)SCNA|0~~16777215.7 3297 +|(% style="width:461px" %)DPTB|0~~16777215.7 3298 +|(% style="width:461px" %)DCNA|0~~16777215.7 3299 +|(% style="width:461px" %)METF|0~~16777215.7 3300 +|(% style="width:461px" %)SENC|0~~16777215.7 3301 +|(% style="width:461px" %)SENA|0~~16777215.7 3302 +|(% style="width:461px" %)MENA|0~~16777215.7 3303 +|(% style="width:461px" %)METD|0~~16777215.7 3304 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 3305 +|(% style="width:461px" %)SCNA|0~~16777215 3306 +|(% style="width:461px" %)DPTB|0~~16777215 3307 +|(% style="width:461px" %)DCNA|0~~16777215 3308 +|(% style="width:461px" %)SENA|0~~16777215 3309 +|(% style="width:461px" %)MENA|0~~16777215 3310 +|(% style="width:461px" %)METD|0~~16777215 3311 +|(% style="width:461px" %)INRO|0~~16777215 3312 +|(% style="width:461px" %)TIMESYN|0~~16777215 3313 +|(% style="width:461px" %)TIMEZ|0~~16777215 3314 +|(% style="width:461px" %)NTP|0~~16777215 3315 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 3316 +|(% style="width:461px" %)SENC|0~~16777215 3317 + 3318 +**Address Configuration** 3319 + 3320 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 3321 + 3322 +(% style="text-align:center" %) 3323 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 3324 + 3325 +(% style="text-align:center" %) 3326 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 3327 + 3328 +Extended tag name 3329 + 3330 +Address range for the extended tag. 3331 + 3332 +**Communication Settings** 3333 + 3334 +Enable HMI Ethernet in [Project Settings]; 3335 + 3336 +(% style="text-align:center" %) 3337 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3338 + 3339 +Set PLC IP in [Device IP] settings; 3340 + 3341 +(% style="text-align:center" %) 3342 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 3343 + 3344 +**Cable Wiring** 3345 + 3346 +(% style="text-align:center" %) 3347 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 3348 + 3349 += **LG XGK FEnet Ethernet** = 3350 + 3351 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 3352 + 3353 +**HMI Settings** 3354 + 3355 +(% class="table-bordered" %) 3356 +|**Items**|**Settings**|**Note** 3357 +|Protocol|LG XGK FEnet(Ethernet)| 3358 +|Connection|Ethernet| 3359 +|Port No.|2004| 3360 + 3361 +**Address List** 3362 + 3363 +(% class="table-bordered" %) 3364 +|**Type**|**Register**|**Range**|**Format**|**Note** 3365 +|(% rowspan="14" %)Word|P|0~~2047|P d| 3366 +|M|0~~2047|M d| 3367 +|K|0~~2047|K d| 3368 +|F|0~~2047|F d| 3369 +|T|0~~2047|T d| 3370 +|C|0~~2047|C d| 3371 +|Z|0~~127|Z d| 3372 +|S|0~~127|S d| 3373 +|L|0~~11263|L d| 3374 +|N|0~~21503|N d| 3375 +|D|0~~32767|D d| 3376 +|R|0~~32767|R d| 3377 +|ZR|0~~65535|ZR d| 3378 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 3379 + 3380 +**✎Note:** 3381 + 3382 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 3383 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 3384 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 3385 + 3386 +**Communication settings in HMI** 3387 + 3388 +Enable HMI Ethernet in [Project Settings]; 3389 + 3390 +(% style="text-align:center" %) 3391 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 3392 + 3393 +Set PLC IP in [Device IP] settings; 3394 + 3395 +(% style="text-align:center" %) 3396 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 3397 + 3398 +**Cable Wiring** 3399 + 3400 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]