Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 66.1
edited by Ben
on 2022/08/29 14:06
Change comment: There is no comment for this version
To version 84.1
edited by Ben
on 2022/08/29 14:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,7 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 +== **LX3V Serial Protocol** ==
90 90  
91 91  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 92  
... ... @@ -140,7 +140,8 @@
140 140  
141 141  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 142  
143 -== HMI settings ==
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
144 144  
145 145  **Download PIStudio Software**
146 146  
... ... @@ -229,7 +229,8 @@
229 229  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 230  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 231  
232 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
233 233  
234 234  **Download PLC Software**
235 235  
... ... @@ -314,7 +314,7 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **HMI and Wecon LX5V serial communication** =
320 +== **LX5V Serial Protocol** ==
318 318  
319 319  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
320 320  
... ... @@ -392,11 +392,10 @@
392 392  
393 393  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
394 394  
395 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
396 396  
397 397  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
398 398  
399 -
400 400  **Software configuration of PLC**
401 401  
402 402  **1)PLC programming software**
... ... @@ -466,10 +466,49 @@
466 466  
467 467  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
468 468  
469 -= =
471 += Create communication with **Rockwell PLC** =
470 470  
471 -= **Allen-Bradley** =
473 +== **MicroLogix Protocol** ==
472 472  
475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
476 +
477 +**HMI Settings**
478 +
479 +(% class="table-bordered" %)
480 +|**Item**|**Settings**|**Note**
481 +|Protocol|Allen-Bradlley MicroLogix|
482 +|Connection|RS232|
483 +|Baud rate|19200|
484 +|Data bit|8|
485 +|Parity|None|
486 +|Stop bit|1|
487 +|PLC station No.|1|
488 +
489 +**Address List**
490 +
491 +(% class="table-bordered" %)
492 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
494 +|O|O d.d|0.0~~255.15|
495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
496 +|S|S d.d|0.0~~255.15|
497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|(% rowspan="9" %)Word|S|S d|0~~255|
499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
500 +|TP|TP nnhh|0~~ffff
501 +|CS|CS nnhh|0~~ffff
502 +|CP|CP nnhh|0~~ffff
503 +|N|N nnhh|0~~ffff
504 +|C|C nnhh|0~~ffff
505 +|T|T nnhh|0~~ffff
506 +|R|R nnhh|0~~ffff
507 +
508 +**Cable Wiring**
509 +
510 +
511 +(% style="text-align:center" %)
512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 +
473 473  == **FreeTag Ethernet/IP (CompactLogix)** ==
474 474  
475 475  Allen-Brandly CompactLogix
... ... @@ -527,46 +527,6 @@
527 527  (% style="text-align:center" %)
528 528  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
529 529  
530 -== **MicroLogix** ==
531 -
532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
533 -
534 -**HMI Settings**
535 -
536 -(% class="table-bordered" %)
537 -|**Item**|**Settings**|**Note**
538 -|Protocol|Allen-Bradlley MicroLogix|
539 -|Connection|RS232|
540 -|Baud rate|19200|
541 -|Data bit|8|
542 -|Parity|None|
543 -|Stop bit|1|
544 -|PLC station No.|1|
545 -
546 -**Address List**
547 -
548 -(% class="table-bordered" %)
549 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
551 -|O|O d.d|0.0~~255.15|
552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
553 -|S|S d.d|0.0~~255.15|
554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
555 -|(% rowspan="9" %)Word|S|S d|0~~255|
556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
557 -|TP|TP nnhh|0~~ffff
558 -|CS|CS nnhh|0~~ffff
559 -|CP|CP nnhh|0~~ffff
560 -|N|N nnhh|0~~ffff
561 -|C|C nnhh|0~~ffff
562 -|T|T nnhh|0~~ffff
563 -|R|R nnhh|0~~ffff
564 -
565 -**Cable Wiring**
566 -
567 -(% style="text-align:center" %)
568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
569 -
570 570  == **AB PLC address edit** ==
571 571  
572 572  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -584,117 +584,280 @@
584 584  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
585 585  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
586 586  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
587 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
588 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
589 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
590 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
591 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
592 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
593 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
594 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
595 595  
596 -= **Barcode Scanner** =
597 += (% id="cke_bm_43878S" style="display:none" %)** **(%%)**Siemens** =
597 597  
598 -Supported: DELI 14880 barcode scanner
599 +== **S7-200 Smart Ethernet** ==
599 599  
601 +Supported Series: Siemens S7-200 SMART Series Ethernet Module.
602 +
603 +Website: [[http:~~/~~/www.siemens.com/entry/cc/en/>>url:http://www.siemens.com/entry/cc/en/]]
604 +
600 600  **HMI Setting**
601 601  
602 602  (% class="table-bordered" %)
603 603  |**Items**|**Settings**|**Note**
604 -|Protocol|Barcode Scanner|
605 -|Connection|USB|
609 +|Protocol|Simens S7-200 Smart Ethernet|
610 +|Connection|Ethernet|
611 +|Port No.|102|
612 +|PLC station No.|2|
606 606  
607 -**Operating Procedures**
614 +**Address List**
608 608  
609 -Select [Barcode Scanner];
616 +(% class="table-bordered" %)
617 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
618 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
619 +|Q|Q|Q ddddd.o|0.0~~99999.7|
620 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
621 +|V|V|V ddddd.o|0.0~~99999.7|
622 +|M|M|M ddddd.o|0.0~~99999.7|
623 +|SM|SM|ddddd.o|0.0~~99999.7|
624 +|S|S|ddddd.o|0.0~~99999.7|Read only
625 +|T|T|ddddd|0~~99999|Timer state, read only
626 +|C|C|ddddd|0~~99999|Counter state, read only
627 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
628 +|Q|QW|QW ddddd|0~~99999|
629 +|AI|AIW|AIW ddddd|0~~99999|
630 +|AQ|VB|VB ddddd|0~~99999|
631 +|V|VW|VW ddddd|0~~99998|(((
632 +VW0=VB (0~~1)
610 610  
634 +VW2=VB (2~~3)
635 +
636 +Address value is a multiple of 2
637 +)))
638 +|V|VD|VD ddddd|0~~99998|(((
639 +VD0=VB (0~~3)
640 +
641 +VD2=VB (4~~7)
642 +
643 +Address value is a multiple of 4
644 +)))
645 +|M|MB|MB ddddd|0~~99999|
646 +|M|MW|MW ddddd|0~~99999|(((
647 +MW0=MB(0~~1)
648 +
649 +MW2=MB(2~~3)
650 +
651 +Address value is a multiple of 2
652 +)))
653 +|M|MD|MD ddddd|0~~99999|(((
654 +MD0=MB(0~~3)
655 +
656 +MD4=MB(4~~7)
657 +
658 +Address value is a multiple of 4
659 +)))
660 +|T|TW|TW ddddd|0~~99999|Value of timer
661 +|C|CW|CW ddddd|0~~99999|Value of counter
662 +|W|SW|SW ddddd|0~~99999|
663 +
664 +**Communication Settings**
665 +
666 +Enable HMI Ethernet in [Project Settings];
667 +
611 611  (% style="text-align:center" %)
612 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
669 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
613 613  
614 -Set address for receiving;
671 +Set PLC IP in [Device IP] settings;
615 615  
616 -Set correct length;
673 +(% style="text-align:center" %)
674 +[[image:12.PLC Protocol_html_70b0c4c2ee21b10d.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
617 617  
676 +* PLC IP Address: PLC IP
677 +* PLC pot No.: 102(fixed)
678 +* Network:TCP_Client_2N(fixed)
679 +
618 618  (% style="text-align:center" %)
619 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
681 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
620 620  
621 -**✎Note:**
683 +* Wait timeout: depend on actual network situation (more than 1500 ms)
622 622  
623 -* The protocol uploads the information acquired by the USB scanner to the HMI;
624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
625 -* Recommended model: DELI 14880 barcode scanner;
685 +**Cable Wiring**
626 626  
627 -= **Hitachi EHV Series (Ethernet)** =
687 +(% style="text-align:center" %)
688 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
628 628  
629 -Supported series: Hitachi EHV series
690 +== **S7-300 Ethernet** ==
630 630  
631 -**HMI Settings**
692 +Supported Series: Siemens S7-300 series PLC
632 632  
694 +**HMI Setting**
695 +
633 633  (% class="table-bordered" %)
634 634  |**Items**|**Settings**|**Note**
635 -|Protocol|Hitachi EHV series|
698 +|Protocol|Simens S7-300 Ethernet|
636 636  |Connection|Ethernet|
637 -|Port No.|3004~~3007|
700 +|Port No.|102|
701 +|PLC station No.|2|Need to be same as the PLC setting
638 638  
639 639  **Address List**
640 640  
641 641  (% class="table-bordered" %)
642 -|**Type**|**Register**|**Range**|**Format**|**Note**
643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
644 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
646 -H1H2H3H4 Module main number
706 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
707 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
708 +|Q|Q|Q ddddd.o|0.0~~99999.7|
709 +|M|M|M ddddd.o|0.0~~99999.7|
710 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
711 +nn: block number;
647 647  
648 -H1: Remote number
713 +dddd: address;
714 +)))
715 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
716 +|Q|QW|QW ddddd|0~~99999|
717 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
718 +|MW|MW ddddd|0~~99999|(((
719 +MW0=MB(0~~1)
649 649  
650 -H2: Unit number
721 +MW2=MB(2~~3)
651 651  
652 -H3: Slot number
723 +Address value is a multiple of 2
724 +)))
725 +|MD|MD ddddd|0~~99999|(((
726 +MD0=MB(0~~3)
653 653  
654 -H4: Word number of Module
728 +MD4=MB(4~~7)
655 655  
656 -H Sub number of Module
730 +Address value is a multiple of 4
731 +)))
732 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
733 +nn: block number;
657 657  
658 -For example:X21.3
735 +dddd: address
736 +)))
737 +|DBxDBW|DBxDBW nndddd|0~~99999999
738 +|DBxDBD|DBxDBD nndddd|0~~99999999
659 659  
660 -Slot number 2
740 +**Communication Settings**
661 661  
662 -Word number of module is 1
742 +Enable HMI Ethernet in [Project Settings];
663 663  
664 -Bit number of module is 3
744 +(% style="text-align:center" %)
745 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
665 665  
666 -Remote number and unit number are 0
747 +Set PLC IP in [Device IP] settings;
748 +
749 +(% style="text-align:center" %)
750 +[[image:12.PLC Protocol_html_910b1a0aa9e2201c.png||data-xwiki-image-style-alignment="center" height="188" width="554" class="img-thumbnail"]]
751 +
752 +* PLC IP Address: PLC IP
753 +* PLC pot No.: 102(fixed)
754 +* Network:TCP_Client_2N(fixed)
755 +
756 +(% style="text-align:center" %)
757 +[[image:12.PLC Protocol_html_5891afd92901b7ad.png||data-xwiki-image-style-alignment="center" height="276" width="347" class="img-thumbnail"]]
758 +
759 +* Wait timeout: depend on actual network situation (more than 1500 ms)
760 +
761 +**Cable Wiring**
762 +
763 +(% style="text-align:center" %)
764 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
765 +
766 +== **S7-1200 Ethernet** ==
767 +
768 +Supported Series: Siemens S7-1200
769 +
770 +**HMI Setting**
771 +
772 +(% class="table-bordered" %)
773 +|**Items**|**Settings**|**Note**
774 +|Protocol|Siemens S7-1200|
775 +|Connection|Ethernet|
776 +|Port No.|102|
777 +|PLC station No.|2|
778 +
779 +**Address List**
780 +
781 +(% class="table-bordered" %)
782 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
783 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
784 +d:0~-~-9999
785 +
786 +o:0-7
787 +)))|
788 +|Q|Q|Q d.o|(((
789 +d:0~-~-9999
790 +
791 +o:0-7
792 +)))|
793 +|M|M|M d.o|(((
794 +d:0~-~-9999
795 +
796 +o:0-7
797 +)))|
798 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
799 +nn:0-9999,
800 +
801 +dddd:0-9999,
802 +
803 +o:0-7
804 +)))|(((
805 +nn:DB No.
806 +
807 +dddd:address value
808 +
809 +o: digit address
667 667  )))
668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
669 -|R|0 – FF.f (Hex)|R HH.h|
670 -|L|0 - 73FF.f (Hex)|L HHHH.h|
671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
673 -H1H2H3H4 Module main number
811 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
812 +|M|MW|MW d|d:0-99999|(((
813 +MW0=MB(0~~1)
674 674  
675 -H1: Remote number
815 +MW2=MB(2~~3)
676 676  
677 -H2: Unit number
817 +Address value is a multiple of 2
818 +)))
819 +|M|MD|MD d|d:0-99999|(((
820 +MD0=MB(0~~3)
678 678  
679 -H3: Slot number
822 +MD4=MB(4~~7)
680 680  
681 -H4: Word number of module
824 +Address value is a multiple of 4
825 +)))
826 +|I|IW|IW d|d:0-99999|
827 +|Q|QW|QW d|d:0-99999|
828 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
829 +nn:0-9999
682 682  
683 -For example:WX21
831 +dddd:0-9999
832 +)))|(((
833 +nn:DB No.
684 684  
685 -Word number of module is 1
835 +dddd:address value
836 +)))
837 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
838 +nn:0-9999
686 686  
687 -Slot number is 2
840 +dddd:0-9999
841 +)))|(((
842 +nn:DB No.
688 688  
689 -Remote number and unit number are 0
844 +dddd:address value
845 +
846 +Address value is a multiple of 2
690 690  )))
691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
692 -|WR|0 – FFFF (Hex)|WR HHHH|
693 -|WL|0 - 73FF (Hex)|WL HHHH|
694 -|TC|0 - 2559|TC DDDD|
848 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
849 +nn:0-9999
695 695  
696 -**Communication settings in HMI**
851 +dddd:0-9999
852 +)))|(((
853 +nn:DB No.
697 697  
855 +dddd:address value
856 +
857 +Address value is a multiple of 4
858 +)))
859 +
860 +**Communication Settings**
861 +
698 698  Enable HMI Ethernet in [Project Settings];
699 699  
700 700  (% style="text-align:center" %)
... ... @@ -703,178 +703,285 @@
703 703  Set PLC IP in [Device IP] settings;
704 704  
705 705  (% style="text-align:center" %)
706 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
870 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
707 707  
708 -**PLC Configuration**
872 +**✎Note:**
709 709  
710 -Connect with PLC, select[Online mode];
874 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
875 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
711 711  
712 -(% style="text-align:center" %)
713 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
877 +**PLC Settings**
714 714  
715 -Set IP address, it is the same LAN parameters with HMI;
879 +Add BD
716 716  
881 +* Please uncheck [Symbolic access only] option;
882 +
717 717  (% style="text-align:center" %)
718 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
884 +[[image:12.PLC Protocol_html_643144c591994418.png||data-xwiki-image-style-alignment="center" height="546" width="550" class="img-thumbnail"]]
719 719  
720 -3) Save PLC communication parameter, and restart PLC
886 +Address settings, using BD2 as example.
721 721  
722 -**PLC Monitor Mode**
888 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1.
889 +* 2 represent DB block number
890 +* xxxx represent address
723 723  
724 -Connect with PLC and choose to “online” mode
892 +**Such as:**
725 725  
894 +* DBxDBB20000 = DB2.DBB0
895 +* DBxDBW20004 = DB2.DBW4
896 +
726 726  (% style="text-align:center" %)
727 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
898 +[[image:12.PLC Protocol_html_87ceaea84d552e62.png||data-xwiki-image-style-alignment="center" height="245" width="537" class="img-thumbnail"]]
728 728  
729 -Open I/O monitor sheet1
900 +**How to connect with S7-1200 Firmware V4.0**
730 730  
731 -(% style="text-align:center" %)
732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
902 +PLC configuration
733 733  
734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
904 +* Double click [device configuration] in Siemens via software
905 +* Double click [protection] to enter protection configuration screen
735 735  
736 736  (% style="text-align:center" %)
737 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
908 +[[image:12.PLC Protocol_html_9779940d38da8e07.png||data-xwiki-image-style-alignment="center" height="426" width="341" class="img-thumbnail"]]
738 738  
739 -Enter the register address, click OK to view the value of the register.
910 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)]
740 740  
741 741  (% style="text-align:center" %)
742 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
913 +[[image:12.PLC Protocol_html_d2c667b02f9720b1.png||data-xwiki-image-style-alignment="center" height="296" width="554" class="img-thumbnail"]]
743 743  
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
915 +DB settings
746 746  
747 -**✎Note:**
917 +* Right click [DB], select [properties]
918 +* Uncheck [optimized block access]
748 748  
749 -* Both word registers and bit registers support even continuous read/write functions;
750 -* The range of registers is based on the specific PLC type;
751 -
752 752  **Cable Wiring**
753 753  
754 754  (% style="text-align:center" %)
755 755  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
756 756  
757 -= **IEC60870-5 104 Client** =
925 +== **LOGO Ethernet** ==
758 758  
759 -**HMI Setting**
927 +Supported Series: Siemens Logo 0BA0 series
760 760  
929 +**HMI Settings**
930 +
761 761  (% class="table-bordered" %)
762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|Siemens LOGO|
934 +|Connection|Ethernet|
935 +|Port No.|102|
936 +|PLC station No.|2|
766 766  
767 767  **Address List**
768 768  
769 769  (% class="table-bordered" %)
770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
772 -|(% style="width:461px" %)SCNA|0~~16777215.7
773 -|(% style="width:461px" %)DPTB|0~~16777215.7
774 -|(% style="width:461px" %)DCNA|0~~16777215.7
775 -|(% style="width:461px" %)METF|0~~16777215.7
776 -|(% style="width:461px" %)SENC|0~~16777215.7
777 -|(% style="width:461px" %)SENA|0~~16777215.7
778 -|(% style="width:461px" %)MENA|0~~16777215.7
779 -|(% style="width:461px" %)METD|0~~16777215.7
780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
781 -|(% style="width:461px" %)SCNA|0~~16777215
782 -|(% style="width:461px" %)DPTB|0~~16777215
783 -|(% style="width:461px" %)DCNA|0~~16777215
784 -|(% style="width:461px" %)SENA|0~~16777215
785 -|(% style="width:461px" %)MENA|0~~16777215
786 -|(% style="width:461px" %)METD|0~~16777215
787 -|(% style="width:461px" %)INRO|0~~16777215
788 -|(% style="width:461px" %)TIMESYN|0~~16777215
789 -|(% style="width:461px" %)TIMEZ|0~~16777215
790 -|(% style="width:461px" %)NTP|0~~16777215
791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
792 -|(% style="width:461px" %)SENC|0~~16777215
941 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
942 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
943 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
944 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
945 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
946 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
947 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
948 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
949 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
950 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
951 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
952 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
953 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
954 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
955 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
956 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
793 793  
794 -**Address Configuration**
958 +**PLC Settings in LOGO Software:**
795 795  
796 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
960 +Click [Tools]~-~-[Ethernet Connections],shown as below.
797 797  
798 798  (% style="text-align:center" %)
799 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
963 +[[image:12.PLC Protocol_html_8b9d2322edf89519.png||data-xwiki-image-style-alignment="center" height="641" width="423" class="img-thumbnail"]]
800 800  
965 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
966 +
801 801  (% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
968 +[[image:12.PLC Protocol_html_6c4dd041b26cd8a1.png||data-xwiki-image-style-alignment="center" height="481" width="363" class="img-thumbnail"]]
803 803  
804 -Extended tag name
970 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
805 805  
806 -Address range for the extended tag.
972 +(% style="text-align:center" %)
973 +[[image:12.PLC Protocol_html_7af2611d3790a77d.png||data-xwiki-image-style-alignment="center" height="359" width="426" class="img-thumbnail"]]
807 807  
808 -**Communication Settings**
975 +**Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
809 809  
810 -Enable HMI Ethernet in [Project Settings];
977 +(% style="text-align:center" %)
978 +[[image:12.PLC Protocol_html_3243e4cd600595cc.png||data-xwiki-image-style-alignment="center" height="368" width="554" class="img-thumbnail"]]
811 811  
980 +
812 812  (% style="text-align:center" %)
813 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
982 +[[image:12.PLC Protocol_html_cb1d92e2cc91a8db.png||data-xwiki-image-style-alignment="center" height="320" width="553" class="img-thumbnail"]]
814 814  
984 +
985 +**HMI Communication Settings**
986 +
815 815  Set PLC IP in [Device IP] settings;
816 816  
817 817  (% style="text-align:center" %)
818 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
990 +[[image:SiemensLOGODeviceIP.png]]
819 819  
992 +Enable HMI Ethernet in [Project Settings];
993 +
994 +(% style="text-align:center" %)
995 +[[image:12.PLC Protocol_html_95917a3d92068467.png||data-xwiki-image-style-alignment="center" height="311" width="553" class="img-thumbnail"]]
996 +
997 +TSAP setting
998 +
999 +* Regarding the setting of PLC TSAP, HMI provides system special address for setting, it is recommended to run in HMI script initialization, write PLC TSAP to corresponding system special register.
1000 +* HSW10118 = local TSAP of HMI, this is remote TSAP of PLC.
1001 +* HSW10119 = Remote TSAP of HMI, this is local TSAP of PLC.
1002 +
1003 +**✎Note:**
1004 +
1005 +* The data of TSAP is hexadecimal format. For example: the remote TSAP configured in the PLC is set to 20.00, then HSW10118 should be set to 0x2000, that is, HSW10118 = 8192.
1006 +
1007 +(% style="text-align:center" %)
1008 +[[image:12.PLC Protocol_html_5c6374b21f46e01e.png||data-xwiki-image-style-alignment="center" height="139" width="498" class="img-thumbnail"]]
1009 +
1010 +
1011 +* AI word address and Ibit address are read-only and cannot be written on HMI.
1012 +* VW address should be even number.such as VW0, VW2, VW4...
1013 +* VD address it takes two VW addresses.such as VD0,VD4,VD8...
1014 +* Written value of RTC cannot exceed 255.
1015 +
820 820  **Cable Wiring**
821 821  
822 822  (% style="text-align:center" %)
823 823  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
824 824  
825 -= **LG XGK FEnet Ethernet** =
1021 +== **S7-XXX Ethernet** ==
826 826  
827 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1023 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
828 828  
829 -**HMI Settings**
1025 +**HMI Setting**
830 830  
831 -(% class="table-bordered" %)
832 -|**Items**|**Settings**|**Note**
833 -|Protocol|LG XGK FEnet(Ethernet)|
834 -|Connection|Ethernet|
835 -|Port No.|2004|
1027 +(% class="table-bordered" style="width:823px" %)
1028 +|=**Items**|=(% style="width: 437px;" %)**Settings**|=(% style="width: 201px;" %)**Note**
1029 +|Protocol|(% style="width:437px" %)Siemens S7-XXX|(% style="width:201px" %)
1030 +|Connection|(% style="width:437px" %)Ethernet|(% style="width:201px" %)
1031 +|Port No.|(% style="width:437px" %)102|(% style="width:201px" %)
1032 +|Device No.|(% style="width:437px" %)Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|(% style="width:201px" %)
1033 +|HMI No.|(% style="width:437px" %)Rack (Default as 0)|(% style="width:201px" %)
836 836  
1035 +Slot from TIA Portal is equal to Device No. of PIStudio
1036 +
1037 +Rack from TIA Portal is equal to HMI No. of PIStudio
1038 +
1039 +(% style="text-align:center" %)
1040 +[[image:S7-XXXCommunication Settings.png]]
1041 +
1042 +(% style="text-align:center" %)
1043 +[[image:S7-XXXCommunication SettingsPIStudio.png||alt="S7-XXXCommunication SettingsPI.png"]]
1044 +
837 837  **Address List**
838 838  
839 839  (% class="table-bordered" %)
840 -|**Type**|**Register**|**Range**|**Format**|**Note**
841 -|(% rowspan="14" %)Word|P|0~~2047|P d|
842 -|M|0~~2047|M d|
843 -|K|0~~2047|K d|
844 -|F|0~~2047|F d|
845 -|T|0~~2047|T d|
846 -|C|0~~2047|C d|
847 -|Z|0~~127|Z d|
848 -|S|0~~127|S d|
849 -|L|0~~11263|L d|
850 -|N|0~~21503|N d|
851 -|D|0~~32767|D d|
852 -|R|0~~32767|R d|
853 -|ZR|0~~65535|ZR d|
854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1048 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
1049 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
1050 +d:0~-~-9999
855 855  
856 -**✎Note:**
1052 +o:0-7
1053 +)))|
1054 +|Q|Q|Q d.o|(((
1055 +d:0~-~-9999
857 857  
858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
860 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
1057 +o:0-7
1058 +)))|
1059 +|M|M|M d.o|(((
1060 +d:0~-~-9999
861 861  
862 -**Communication settings in HMI**
1062 +o:0-7
1063 +)))|
1064 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
1065 +nn:0-9999,
863 863  
1067 +dddd:0-9999,
1068 +
1069 +o:0-7
1070 +)))|(((
1071 +nn:DB No.
1072 +
1073 +dddd:address value
1074 +
1075 +o: digit address
1076 +)))
1077 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
1078 +|M|MW|MW d|d:0-99999|(((
1079 +MW0=MB(0~~1)
1080 +
1081 +MW2=MB(2~~3)
1082 +
1083 +Address value is a multiple of 2
1084 +)))
1085 +|M|MD|MD d|d:0-99999|(((
1086 +MD0=MB(0~~3)
1087 +
1088 +MD4=MB(4~~7)
1089 +
1090 +Address value is a multiple of 4
1091 +)))
1092 +|I|IW|IW d|d:0-99999|
1093 +|Q|QW|QW d|d:0-99999|
1094 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
1095 +nn:0-9999
1096 +
1097 +dddd:0-9999
1098 +)))|(((
1099 +nn:DB No.
1100 +
1101 +dddd:address value
1102 +)))
1103 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
1104 +nn:0-9999
1105 +
1106 +dddd:0-9999
1107 +)))|(((
1108 +nn:DB No.
1109 +
1110 +dddd:address value
1111 +
1112 +Address value is a multiple of 2
1113 +)))
1114 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
1115 +nn:0-9999
1116 +
1117 +dddd:0-9999
1118 +)))|(((
1119 +nn:DB No.
1120 +
1121 +dddd:address value
1122 +
1123 +Address value is a multiple of 4
1124 +)))
1125 +
1126 +**Communication Settings**
1127 +
864 864  Enable HMI Ethernet in [Project Settings];
865 865  
866 866  (% style="text-align:center" %)
867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
1131 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
868 868  
869 869  Set PLC IP in [Device IP] settings;
870 870  
871 871  (% style="text-align:center" %)
872 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
1136 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
873 873  
1138 +**✎Note:**
1139 +
1140 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
1141 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
1142 +
874 874  **Cable Wiring**
875 875  
876 -= **Mitsubishi** =
1145 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
877 877  
1147 += Create communication with **Mitsubishi** =
1148 +
878 878  == **FX1S, 1N, 2N Series** ==
879 879  
880 880  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -2646,8 +2646,6 @@
2646 2646  
2647 2647  **✎Note:** COM3 only available in PI8000/PI9000 series.
2648 2648  
2649 -= =
2650 -
2651 2651  = **Printer** =
2652 2652  
2653 2653  == **TSPL label printer** ==
... ... @@ -2848,3 +2848,284 @@
2848 2848  
2849 2849  (% style="text-align:center" %)
2850 2850  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
3120 +
3121 += **Barcode Scanner** =
3122 +
3123 +Supported: DELI 14880 barcode scanner
3124 +
3125 +**HMI Setting**
3126 +
3127 +|**Items**|**Settings**|**Note**
3128 +|Protocol|Barcode Scanner|
3129 +|Connection|USB|
3130 +
3131 +**Operating Procedures**
3132 +
3133 +Select [Barcode Scanner];
3134 +
3135 +(% style="text-align:center" %)
3136 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
3137 +
3138 +Set address for receiving;
3139 +
3140 +Set correct length;
3141 +
3142 +(% style="text-align:center" %)
3143 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
3144 +
3145 +**✎Note:**
3146 +
3147 +* The protocol uploads the information acquired by the USB scanner to the HMI;
3148 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
3149 +* Recommended model: DELI 14880 barcode scanner;
3150 +
3151 += **Hitachi EHV Series (Ethernet)** =
3152 +
3153 +Supported series: Hitachi EHV series
3154 +
3155 +**HMI Settings**
3156 +
3157 +(% class="table-bordered" %)
3158 +|**Items**|**Settings**|**Note**
3159 +|Protocol|Hitachi EHV series|
3160 +|Connection|Ethernet|
3161 +|Port No.|3004~~3007|
3162 +
3163 +**Address List**
3164 +
3165 +(% class="table-bordered" %)
3166 +|**Type**|**Register**|**Range**|**Format**|**Note**
3167 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
3168 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
3169 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
3170 +H1H2H3H4 Module main number
3171 +
3172 +H1: Remote number
3173 +
3174 +H2: Unit number
3175 +
3176 +H3: Slot number
3177 +
3178 +H4: Word number of Module
3179 +
3180 +H Sub number of Module
3181 +
3182 +For example:X21.3
3183 +
3184 +Slot number 2
3185 +
3186 +Word number of module is 1
3187 +
3188 +Bit number of module is 3
3189 +
3190 +Remote number and unit number are 0
3191 +)))
3192 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
3193 +|R|0 – FF.f (Hex)|R HH.h|
3194 +|L|0 - 73FF.f (Hex)|L HHHH.h|
3195 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
3196 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
3197 +H1H2H3H4 Module main number
3198 +
3199 +H1: Remote number
3200 +
3201 +H2: Unit number
3202 +
3203 +H3: Slot number
3204 +
3205 +H4: Word number of module
3206 +
3207 +For example:WX21
3208 +
3209 +Word number of module is 1
3210 +
3211 +Slot number is 2
3212 +
3213 +Remote number and unit number are 0
3214 +)))
3215 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
3216 +|WR|0 – FFFF (Hex)|WR HHHH|
3217 +|WL|0 - 73FF (Hex)|WL HHHH|
3218 +|TC|0 - 2559|TC DDDD|
3219 +
3220 +**Communication settings in HMI**
3221 +
3222 +Enable HMI Ethernet in [Project Settings];
3223 +
3224 +(% style="text-align:center" %)
3225 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3226 +
3227 +Set PLC IP in [Device IP] settings;
3228 +
3229 +(% style="text-align:center" %)
3230 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
3231 +
3232 +**PLC Configuration**
3233 +
3234 +Connect with PLC, select[Online mode];
3235 +
3236 +(% style="text-align:center" %)
3237 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
3238 +
3239 +Set IP address, it is the same LAN parameters with HMI;
3240 +
3241 +(% style="text-align:center" %)
3242 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
3243 +
3244 +3) Save PLC communication parameter, and restart PLC
3245 +
3246 +**PLC Monitor Mode**
3247 +
3248 +Connect with PLC and choose to “online” mode
3249 +
3250 +(% style="text-align:center" %)
3251 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
3252 +
3253 +Open I/O monitor sheet1
3254 +
3255 +(% style="text-align:center" %)
3256 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
3257 +
3258 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
3259 +
3260 +(% style="text-align:center" %)
3261 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
3262 +
3263 +Enter the register address, click OK to view the value of the register.
3264 +
3265 +(% style="text-align:center" %)
3266 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3267 +
3268 +(% style="text-align:center" %)
3269 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
3270 +
3271 +**✎Note:**
3272 +
3273 +* Both word registers and bit registers support even continuous read/write functions;
3274 +* The range of registers is based on the specific PLC type;
3275 +
3276 +**Cable Wiring**
3277 +
3278 +(% style="text-align:center" %)
3279 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3280 +
3281 += **IEC60870-5 104 Client** =
3282 +
3283 +**HMI Setting**
3284 +
3285 +(% class="table-bordered" %)
3286 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
3287 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
3288 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
3289 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
3290 +
3291 +**Address List**
3292 +
3293 +(% class="table-bordered" %)
3294 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
3295 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
3296 +|(% style="width:461px" %)SCNA|0~~16777215.7
3297 +|(% style="width:461px" %)DPTB|0~~16777215.7
3298 +|(% style="width:461px" %)DCNA|0~~16777215.7
3299 +|(% style="width:461px" %)METF|0~~16777215.7
3300 +|(% style="width:461px" %)SENC|0~~16777215.7
3301 +|(% style="width:461px" %)SENA|0~~16777215.7
3302 +|(% style="width:461px" %)MENA|0~~16777215.7
3303 +|(% style="width:461px" %)METD|0~~16777215.7
3304 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
3305 +|(% style="width:461px" %)SCNA|0~~16777215
3306 +|(% style="width:461px" %)DPTB|0~~16777215
3307 +|(% style="width:461px" %)DCNA|0~~16777215
3308 +|(% style="width:461px" %)SENA|0~~16777215
3309 +|(% style="width:461px" %)MENA|0~~16777215
3310 +|(% style="width:461px" %)METD|0~~16777215
3311 +|(% style="width:461px" %)INRO|0~~16777215
3312 +|(% style="width:461px" %)TIMESYN|0~~16777215
3313 +|(% style="width:461px" %)TIMEZ|0~~16777215
3314 +|(% style="width:461px" %)NTP|0~~16777215
3315 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
3316 +|(% style="width:461px" %)SENC|0~~16777215
3317 +
3318 +**Address Configuration**
3319 +
3320 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
3321 +
3322 +(% style="text-align:center" %)
3323 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
3324 +
3325 +(% style="text-align:center" %)
3326 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
3327 +
3328 +Extended tag name
3329 +
3330 +Address range for the extended tag.
3331 +
3332 +**Communication Settings**
3333 +
3334 +Enable HMI Ethernet in [Project Settings];
3335 +
3336 +(% style="text-align:center" %)
3337 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3338 +
3339 +Set PLC IP in [Device IP] settings;
3340 +
3341 +(% style="text-align:center" %)
3342 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
3343 +
3344 +**Cable Wiring**
3345 +
3346 +(% style="text-align:center" %)
3347 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
3348 +
3349 += **LG XGK FEnet Ethernet** =
3350 +
3351 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
3352 +
3353 +**HMI Settings**
3354 +
3355 +(% class="table-bordered" %)
3356 +|**Items**|**Settings**|**Note**
3357 +|Protocol|LG XGK FEnet(Ethernet)|
3358 +|Connection|Ethernet|
3359 +|Port No.|2004|
3360 +
3361 +**Address List**
3362 +
3363 +(% class="table-bordered" %)
3364 +|**Type**|**Register**|**Range**|**Format**|**Note**
3365 +|(% rowspan="14" %)Word|P|0~~2047|P d|
3366 +|M|0~~2047|M d|
3367 +|K|0~~2047|K d|
3368 +|F|0~~2047|F d|
3369 +|T|0~~2047|T d|
3370 +|C|0~~2047|C d|
3371 +|Z|0~~127|Z d|
3372 +|S|0~~127|S d|
3373 +|L|0~~11263|L d|
3374 +|N|0~~21503|N d|
3375 +|D|0~~32767|D d|
3376 +|R|0~~32767|R d|
3377 +|ZR|0~~65535|ZR d|
3378 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
3379 +
3380 +**✎Note:**
3381 +
3382 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
3383 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
3384 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
3385 +
3386 +**Communication settings in HMI**
3387 +
3388 +Enable HMI Ethernet in [Project Settings];
3389 +
3390 +(% style="text-align:center" %)
3391 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
3392 +
3393 +Set PLC IP in [Device IP] settings;
3394 +
3395 +(% style="text-align:center" %)
3396 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
3397 +
3398 +**Cable Wiring**
3399 +
3400 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]