Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -141,7 +141,8 @@ 141 141 142 142 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 143 143 144 -== HMI settings == 144 +(% class="wikigeneratedid" id="HHMIsettings" %) 145 +**HMI settings** 145 145 146 146 **Download PIStudio Software** 147 147 ... ... @@ -230,7 +230,8 @@ 230 230 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 231 231 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 232 232 233 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 234 234 235 235 **Download PLC Software** 236 236 ... ... @@ -467,10 +467,50 @@ 467 467 468 468 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 469 469 470 -= = 472 += Create communication with **Rockwell PLC** = 471 471 472 -= **Allen-Bradley** = 473 473 475 +== **MicroLogix Protocol** == 476 + 477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 + 479 +**HMI Settings** 480 + 481 +(% class="table-bordered" %) 482 +|**Item**|**Settings**|**Note** 483 +|Protocol|Allen-Bradlley MicroLogix| 484 +|Connection|RS232| 485 +|Baud rate|19200| 486 +|Data bit|8| 487 +|Parity|None| 488 +|Stop bit|1| 489 +|PLC station No.|1| 490 + 491 +**Address List** 492 + 493 +(% class="table-bordered" %) 494 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 +|O|O d.d|0.0~~255.15| 497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|S|S d.d|0.0~~255.15| 499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 +|(% rowspan="9" %)Word|S|S d|0~~255| 501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 +|TP|TP nnhh|0~~ffff 503 +|CS|CS nnhh|0~~ffff 504 +|CP|CP nnhh|0~~ffff 505 +|N|N nnhh|0~~ffff 506 +|C|C nnhh|0~~ffff 507 +|T|T nnhh|0~~ffff 508 +|R|R nnhh|0~~ffff 509 + 510 +**Cable Wiring** 511 + 512 + 513 +(% style="text-align:center" %) 514 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 515 + 474 474 == **FreeTag Ethernet/IP (CompactLogix)** == 475 475 476 476 Allen-Brandly CompactLogix ... ... @@ -528,46 +528,6 @@ 528 528 (% style="text-align:center" %) 529 529 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 530 530 531 -== **MicroLogix** == 532 - 533 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 534 - 535 -**HMI Settings** 536 - 537 -(% class="table-bordered" %) 538 -|**Item**|**Settings**|**Note** 539 -|Protocol|Allen-Bradlley MicroLogix| 540 -|Connection|RS232| 541 -|Baud rate|19200| 542 -|Data bit|8| 543 -|Parity|None| 544 -|Stop bit|1| 545 -|PLC station No.|1| 546 - 547 -**Address List** 548 - 549 -(% class="table-bordered" %) 550 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 551 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 552 -|O|O d.d|0.0~~255.15| 553 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 554 -|S|S d.d|0.0~~255.15| 555 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 556 -|(% rowspan="9" %)Word|S|S d|0~~255| 557 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 558 -|TP|TP nnhh|0~~ffff 559 -|CS|CS nnhh|0~~ffff 560 -|CP|CP nnhh|0~~ffff 561 -|N|N nnhh|0~~ffff 562 -|C|C nnhh|0~~ffff 563 -|T|T nnhh|0~~ffff 564 -|R|R nnhh|0~~ffff 565 - 566 -**Cable Wiring** 567 - 568 -(% style="text-align:center" %) 569 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 570 - 571 571 == **AB PLC address edit** == 572 572 573 573 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. ... ... @@ -594,37 +594,6 @@ 594 594 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 595 595 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 596 596 597 -= **Barcode Scanner** = 598 - 599 -Supported: DELI 14880 barcode scanner 600 - 601 -**HMI Setting** 602 - 603 -(% class="table-bordered" %) 604 -|**Items**|**Settings**|**Note** 605 -|Protocol|Barcode Scanner| 606 -|Connection|USB| 607 - 608 -**Operating Procedures** 609 - 610 -Select [Barcode Scanner]; 611 - 612 -(% style="text-align:center" %) 613 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 614 - 615 -Set address for receiving; 616 - 617 -Set correct length; 618 - 619 -(% style="text-align:center" %) 620 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 621 - 622 -**✎Note:** 623 - 624 -* The protocol uploads the information acquired by the USB scanner to the HMI; 625 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 626 -* Recommended model: DELI 14880 barcode scanner; 627 - 628 628 = **Hitachi EHV Series (Ethernet)** = 629 629 630 630 Supported series: Hitachi EHV series ... ... @@ -2647,7 +2647,7 @@ 2647 2647 2648 2648 **✎Note:** COM3 only available in PI8000/PI9000 series. 2649 2649 2650 -= 2621 += = 2651 2651 2652 2652 = **Printer** = 2653 2653