Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -231,7 +231,8 @@ 231 231 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 232 232 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 233 233 234 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 235 235 236 236 **Download PLC Software** 237 237 ... ... @@ -468,10 +468,46 @@ 468 468 469 469 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 470 470 471 -= = 472 += Create communication with **Rockwell PLC** = 472 472 473 -= **Allen-Bradley** = 474 474 475 +== **MicroLogix** == 476 + 477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 + 479 +**HMI Settings** 480 + 481 +(% class="table-bordered" %) 482 +|**Item**|**Settings**|**Note** 483 +|Protocol|Allen-Bradlley MicroLogix| 484 +|Connection|RS232| 485 +|Baud rate|19200| 486 +|Data bit|8| 487 +|Parity|None| 488 +|Stop bit|1| 489 +|PLC station No.|1| 490 + 491 +**Address List** 492 + 493 +(% class="table-bordered" %) 494 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 +|O|O d.d|0.0~~255.15| 497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|S|S d.d|0.0~~255.15| 499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 +|(% rowspan="9" %)Word|S|S d|0~~255| 501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 +|TP|TP nnhh|0~~ffff 503 +|CS|CS nnhh|0~~ffff 504 +|CP|CP nnhh|0~~ffff 505 +|N|N nnhh|0~~ffff 506 +|C|C nnhh|0~~ffff 507 +|T|T nnhh|0~~ffff 508 +|R|R nnhh|0~~ffff 509 + 510 +**Cable Wiring** 511 + 475 475 == **FreeTag Ethernet/IP (CompactLogix)** == 476 476 477 477 Allen-Brandly CompactLogix ... ... @@ -529,43 +529,8 @@ 529 529 (% style="text-align:center" %) 530 530 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 531 531 532 -== **MicroLogix**==569 +== == 533 533 534 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 535 - 536 -**HMI Settings** 537 - 538 -(% class="table-bordered" %) 539 -|**Item**|**Settings**|**Note** 540 -|Protocol|Allen-Bradlley MicroLogix| 541 -|Connection|RS232| 542 -|Baud rate|19200| 543 -|Data bit|8| 544 -|Parity|None| 545 -|Stop bit|1| 546 -|PLC station No.|1| 547 - 548 -**Address List** 549 - 550 -(% class="table-bordered" %) 551 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 552 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 553 -|O|O d.d|0.0~~255.15| 554 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 555 -|S|S d.d|0.0~~255.15| 556 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 557 -|(% rowspan="9" %)Word|S|S d|0~~255| 558 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 559 -|TP|TP nnhh|0~~ffff 560 -|CS|CS nnhh|0~~ffff 561 -|CP|CP nnhh|0~~ffff 562 -|N|N nnhh|0~~ffff 563 -|C|C nnhh|0~~ffff 564 -|T|T nnhh|0~~ffff 565 -|R|R nnhh|0~~ffff 566 - 567 -**Cable Wiring** 568 - 569 569 (% style="text-align:center" %) 570 570 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 571 571 ... ... @@ -2648,7 +2648,7 @@ 2648 2648 2649 2649 **✎Note:** COM3 only available in PI8000/PI9000 series. 2650 2650 2651 -= = 2653 += = 2652 2652 2653 2653 = **Printer** = 2654 2654