Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 69.1
edited by Ben
on 2022/08/29 14:09
Change comment: There is no comment for this version
To version 64.1
edited by Ben
on 2022/08/29 13:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,63 +87,8 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 -== **LX3V Serial Protocol** ==
90 +== HMI settings ==
91 91  
92 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
93 -
94 -**HMI Settings**
95 -
96 -(% class="table-bordered" %)
97 -|**Item**|**Settings**|**Note**
98 -|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
99 -|Connection|RS422/RS485|
100 -|Baud rate|9600|
101 -|Data bit|7|
102 -|Parity|EVEN|
103 -|Stop bit|1|
104 -|PLC station No.|1|
105 -
106 -**Address List**
107 -
108 -(% class="table-bordered" %)
109 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
110 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
111 -|Y|Y|Y o|0~~303237|
112 -|M|M|M d|0~~99999|
113 -|T|T|T d|0~~99999|
114 -|C|C|C d|0~~99999|
115 -|S|S|S d|0~~99999|
116 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
117 -|Y|Y|Y o|0~~303237|
118 -|M|M|M d|0~~99999|
119 -|T|T|T d|0~~99999|
120 -|C|C|C d|0~~199|
121 -|D|D|D d|0~~7999|
122 -|S|S|S d|0~~99999|
123 -|SD|SD|SD d|8000~~9999|
124 -
125 -**Cable Wiring**
126 -
127 -* **RS485**
128 -
129 -(% style="text-align:center" %)
130 -[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
131 -
132 -* **RS422**
133 -
134 -(% style="text-align:center" %)
135 -[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
136 -
137 -**✎Note:**
138 -
139 -* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
140 -* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
141 -
142 -[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
143 -
144 -(% class="wikigeneratedid" id="HHMIsettings" %)
145 -**HMI settings**
146 -
147 147  **Download PIStudio Software**
148 148  
149 149  Please visit the link below to get the latest version PIstudio for HMI programming:
... ... @@ -231,8 +231,7 @@
231 231  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
232 232  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
233 233  
234 -(% class="wikigeneratedid" id="HPLCsettings" %)
235 -**PLC settings**
179 +== PLC settings ==
236 236  
237 237  **Download PLC Software**
238 238  
... ... @@ -317,8 +317,63 @@
317 317  (% style="text-align:center" %)
318 318  [[image:image-20220819105928-9.png||height="229" width="669"]]
319 319  
320 -== **LX5V Serial Protocol** ==
264 += **WECON PLC** =
321 321  
266 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
267 +
268 +**HMI Settings**
269 +
270 +(% class="table-bordered" %)
271 +|**Item**|**Settings**|**Note**
272 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
273 +|Connection|RS422/RS485|
274 +|Baud rate|9600|
275 +|Data bit|7|
276 +|Parity|EVEN|
277 +|Stop bit|1|
278 +|PLC station No.|1|
279 +
280 +**Address List**
281 +
282 +(% class="table-bordered" %)
283 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
284 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
285 +|Y|Y|Y o|0~~303237|
286 +|M|M|M d|0~~99999|
287 +|T|T|T d|0~~99999|
288 +|C|C|C d|0~~99999|
289 +|S|S|S d|0~~99999|
290 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
291 +|Y|Y|Y o|0~~303237|
292 +|M|M|M d|0~~99999|
293 +|T|T|T d|0~~99999|
294 +|C|C|C d|0~~199|
295 +|D|D|D d|0~~7999|
296 +|S|S|S d|0~~99999|
297 +|SD|SD|SD d|8000~~9999|
298 +
299 +**Cable Wiring**
300 +
301 +* **RS485**
302 +
303 +(% style="text-align:center" %)
304 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
305 +
306 +* **RS422**
307 +
308 +(% style="text-align:center" %)
309 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
310 +
311 +**✎Note:**
312 +
313 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
314 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
315 +
316 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
317 +
318 +
319 +== **HMI and Wecon LX5V serial communication** ==
320 +
322 322  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
323 323  
324 324  **Software configuration of PLC**
... ... @@ -395,7 +395,7 @@
395 395  
396 396  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
397 397  
398 -== **LX5V-N Ethernet protocol** ==
397 +== **HMI and Wecon LX5V-N Ethernet communication** ==
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
... ... @@ -469,7 +469,8 @@
469 469  
470 470  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
471 471  
472 -= =
471 +(% class="wikigeneratedid" %)
472 += =
473 473  
474 474  = **Allen-Bradley** =
475 475  
... ... @@ -2649,7 +2649,7 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2652 += =
2653 2653  
2654 2654  = **Printer** =
2655 2655