Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -469,46 +469,8 @@ 469 469 470 470 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 471 471 472 -= Create communication with**RockwellPLC** =472 += **Allen-Bradley** = 473 473 474 - 475 -== **MicroLogix** == 476 - 477 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 478 - 479 -**HMI Settings** 480 - 481 -(% class="table-bordered" %) 482 -|**Item**|**Settings**|**Note** 483 -|Protocol|Allen-Bradlley MicroLogix| 484 -|Connection|RS232| 485 -|Baud rate|19200| 486 -|Data bit|8| 487 -|Parity|None| 488 -|Stop bit|1| 489 -|PLC station No.|1| 490 - 491 -**Address List** 492 - 493 -(% class="table-bordered" %) 494 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 495 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 496 -|O|O d.d|0.0~~255.15| 497 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 -|S|S d.d|0.0~~255.15| 499 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 500 -|(% rowspan="9" %)Word|S|S d|0~~255| 501 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 502 -|TP|TP nnhh|0~~ffff 503 -|CS|CS nnhh|0~~ffff 504 -|CP|CP nnhh|0~~ffff 505 -|N|N nnhh|0~~ffff 506 -|C|C nnhh|0~~ffff 507 -|T|T nnhh|0~~ffff 508 -|R|R nnhh|0~~ffff 509 - 510 -**Cable Wiring** 511 - 512 512 == **FreeTag Ethernet/IP (CompactLogix)** == 513 513 514 514 Allen-Brandly CompactLogix ... ... @@ -566,8 +566,43 @@ 566 566 (% style="text-align:center" %) 567 567 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 568 568 569 -== 531 +== **MicroLogix** == 570 570 533 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 534 + 535 +**HMI Settings** 536 + 537 +(% class="table-bordered" %) 538 +|**Item**|**Settings**|**Note** 539 +|Protocol|Allen-Bradlley MicroLogix| 540 +|Connection|RS232| 541 +|Baud rate|19200| 542 +|Data bit|8| 543 +|Parity|None| 544 +|Stop bit|1| 545 +|PLC station No.|1| 546 + 547 +**Address List** 548 + 549 +(% class="table-bordered" %) 550 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 551 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 552 +|O|O d.d|0.0~~255.15| 553 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 554 +|S|S d.d|0.0~~255.15| 555 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 556 +|(% rowspan="9" %)Word|S|S d|0~~255| 557 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 558 +|TP|TP nnhh|0~~ffff 559 +|CS|CS nnhh|0~~ffff 560 +|CP|CP nnhh|0~~ffff 561 +|N|N nnhh|0~~ffff 562 +|C|C nnhh|0~~ffff 563 +|T|T nnhh|0~~ffff 564 +|R|R nnhh|0~~ffff 565 + 566 +**Cable Wiring** 567 + 571 571 (% style="text-align:center" %) 572 572 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 573 573 ... ... @@ -2650,7 +2650,7 @@ 2650 2650 2651 2651 **✎Note:** COM3 only available in PI8000/PI9000 series. 2652 2652 2653 -= 2650 += = 2654 2654 2655 2655 = **Printer** = 2656 2656